ABB

ABB IPMON01 Bailey INFI 90 Power Montior Module

SKU IPMON01

In stock
  • 12-month warranty
  • Free returns within 30 days
  • Manufacturer: ABB
  • Product No.: IPMON01
  • Origin United States
  • Product Type: Power Montior Module
  • Barcode: 8538908180
  • Payment: T/T, Western Union
  • Weight: 1.542 kg
  • Dimensions: 275 mm x 40 mm x 195 mm (H x W x D)
  • Shipping port: Xiamen
  • Warranty: 12 months

Tags

Product Documentation

Technical Datasheet (PDF) Complete specifications and technical drawings.

Technical Datasheet

ABB IPMON01 Bailey INFI 90 Power Montior Module

Quantity

Product Description

The ABB IPMON01 is a Power Monitor Module designed for the Bailey INFI 90 OPEN Modular Power System II. This module serves as a central diagnostics and monitoring interface within the system, providing real-time data on system bus voltages, input power status, and localized environmental or hardware parameters. The ABB IPMON01 features three red/green status LEDs, eight red alarm LEDs, and an integrated interface for direct diagnostics. It assesses the health of input power lines, system and I/O bus voltages, and external conditions like cabinet temperature and cooling fan operation to protect critical infrastructure.

Features

  • Integrates three dual-color red/green status LEDs (Self-check, Line 1, Line 2) for immediate operational status verification.
  • Features eight dedicated red alarm LEDs to isolate faults such as power supply failure, overtemperature conditions, fan failure, and PFI status.
  • Configurable LED operation controlled via internal dipswitch and jumper settings to monitor multiple lines, buses, and distinct hardware signals.
  • Includes six physical faceplate test points enabling direct bus voltage measurements via voltmeter probes.
  • Equipped with a faceplate PFI reset pushbutton to clear latched power fail interrupt signals after fault conditions resolve.

Applications

  • Bailey INFI 90 OPEN Modular Power System II diagnostic monitoring.
  • Real-time voltage loop and operational fault tracking in industrial power architectures.
  • Overtemperature and cooling fan failure tracking within electronic enclosures.

Technical Specifications

Parameter Specification
Manufacturer ABB / Bailey
Product ID IPMON01
Product Series INFI 90 OPEN Modular Power System II
Module Type Power Monitor Module
Medium Description MODULE ASSY
Status LEDs Self-check (Red/Green), Line 1 (Red/Green), Line 2 (Red/Green)
Alarm LEDs Power supply, Cabinet temp, Fan left, Fan right, External, System power, I/O power, PFI (All Red)
Faceplate Test Points +5 Volts, +15 Volts, -15 Volts, Module Com, +25.5 Volts, I/O Common
Pushbutton Interface PFI Reset Pushbutton
Country of Origin United States (US)
Customs Tariff Number 8538908180
Gross Weight 1.542 kg

Ordering Information

Description Value
Part Type New
Minimum Order Quantity 1 EA
Order Multiple 1 EA
Selling Unit of Measure each

Installation Guidelines

  • Document and verify all dipswitch and jumper configurations prior to module insertion to ensure correct mapping of lines, buses, and alarm signals.
  • Ensure proper structural grounding and isolate power sources before manipulating hardware components inside the drive or system cabinet.
  • Align the module along the chassis guide rails to protect backplane pins and component infrastructure from mechanical damage during seating.
  • Keep an updated copy of the dipswitch and jumper configuration matrix inside or near the cabinet enclosure as a reference guide for maintenance personnel.
Shipping & Returns

Global Express Shipping

  • Standard Delivery: 4–6 business days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our technical warranty.
FAQ
What is the function of the test points on the faceplate of the module?
The six faceplate test points allow technical personnel to take precise bus voltage measurements using physical voltmeter probes.
How do the Self-check and Line 1 LEDs indicate status on the device?
Both are dual-color status LEDs. They remain green during normal operation. The Self-check LED turns red upon detecting an internal hardware failure, and the Line 1 LED turns red if input power falls outside the specified operating range.
What is the purpose of the PFI reset pushbutton on the device?
The PFI reset pushbutton is used to manually clear a latched PFI alarm signal once the underlying power fail interrupt condition has returned to normal parameters.
Reviews

IPMON01

Stock & lead time on request

Call
1 of 3

ABB IPMON01 Bailey INFI 90 Power Montior Module

Only 2 item(s) left in stock
  • Manufacturer: ABB

  • Product No.: IPMON01

  • Country of origin:United States

  • Product Type: Power Montior Module

  • Barcode: 8538908180

  • Payment: T/T, Western Union

  • Weight: 1542g

  • Dimensions: 275 mm x 40 mm x 195 mm (H x W x D)

  • Shipping port: Xiamen

  • Warranty: 12 months

Quantity
View full details

The ABB IPMON01 is a Power Monitor Module designed for the Bailey INFI 90 OPEN Modular Power System II. This module serves as a central diagnostics and monitoring interface within the system, providing real-time data on system bus voltages, input power status, and localized environmental or hardware parameters. The ABB IPMON01 features three red/green status LEDs, eight red alarm LEDs, and an integrated interface for direct diagnostics. It assesses the health of input power lines, system and I/O bus voltages, and external conditions like cabinet temperature and cooling fan operation to protect critical infrastructure.

Features

  • Integrates three dual-color red/green status LEDs (Self-check, Line 1, Line 2) for immediate operational status verification.
  • Features eight dedicated red alarm LEDs to isolate faults such as power supply failure, overtemperature conditions, fan failure, and PFI status.
  • Configurable LED operation controlled via internal dipswitch and jumper settings to monitor multiple lines, buses, and distinct hardware signals.
  • Includes six physical faceplate test points enabling direct bus voltage measurements via voltmeter probes.
  • Equipped with a faceplate PFI reset pushbutton to clear latched power fail interrupt signals after fault conditions resolve.

Applications

  • Bailey INFI 90 OPEN Modular Power System II diagnostic monitoring.
  • Real-time voltage loop and operational fault tracking in industrial power architectures.
  • Overtemperature and cooling fan failure tracking within electronic enclosures.

Technical Specifications

Parameter Specification
Manufacturer ABB / Bailey
Product ID IPMON01
Product Series INFI 90 OPEN Modular Power System II
Module Type Power Monitor Module
Medium Description MODULE ASSY
Status LEDs Self-check (Red/Green), Line 1 (Red/Green), Line 2 (Red/Green)
Alarm LEDs Power supply, Cabinet temp, Fan left, Fan right, External, System power, I/O power, PFI (All Red)
Faceplate Test Points +5 Volts, +15 Volts, -15 Volts, Module Com, +25.5 Volts, I/O Common
Pushbutton Interface PFI Reset Pushbutton
Country of Origin United States (US)
Customs Tariff Number 8538908180
Gross Weight 1.542 kg

Ordering Information

Description Value
Part Type New
Minimum Order Quantity 1 EA
Order Multiple 1 EA
Selling Unit of Measure each

Installation Guidelines

  • Document and verify all dipswitch and jumper configurations prior to module insertion to ensure correct mapping of lines, buses, and alarm signals.
  • Ensure proper structural grounding and isolate power sources before manipulating hardware components inside the drive or system cabinet.
  • Align the module along the chassis guide rails to protect backplane pins and component infrastructure from mechanical damage during seating.
  • Keep an updated copy of the dipswitch and jumper configuration matrix inside or near the cabinet enclosure as a reference guide for maintenance personnel.

Product Documentation

Technical Datasheet (PDF) Complete specifications and technical drawings.

Technical Datasheet

ABB IPMON01 Bailey INFI 90 Power Montior Module

What is the function of the test points on the faceplate of the module?

The six faceplate test points allow technical personnel to take precise bus voltage measurements using physical voltmeter probes.

How do the Self-check and Line 1 LEDs indicate status on the device?

Both are dual-color status LEDs. They remain green during normal operation. The Self-check LED turns red upon detecting an internal hardware failure, and the Line 1 LED turns red if input power falls outside the specified operating range.

What is the purpose of the PFI reset pushbutton on the device?

The PFI reset pushbutton is used to manually clear a latched PFI alarm signal once the underlying power fail interrupt condition has returned to normal parameters.

Global Express Shipping

  • Standard Delivery: 4-6 Business Days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries, including rapid delivery to Saudi Arabia and UAE.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our professional technical warranty.

Orders are processed and delivered Monday-Friday (excluding public holidays).


For full eligibility, restocking fees, and international return details, please view our official Refund & Return Policy .

TECHNICAL SPECIFICATIONS

Color pattern
Dots
Country of origin
United States
Power source
DC Power

Recently Viewed Products

Technical knowledge

Implementing 3-Switch XOR Ladder Logic with Internal Bit

Implement a 3-SPST switch XOR light circuit in LogixPro or RSLogix 500 using an internal relay bit. Includes truth tables, boolean equations, and verified.

Building a Modbus RTU Network with CompactLogix and DeltaV

Integrate Allen-Bradley CompactLogix, Caterpillar ATS, and generators into DeltaV DCS over Modbus RTU. Covers ProSoft MVI69-MCM, Miille DIN266 gateways.

ONS Instruction Not Energizing OTE in Studio 5000 Ladder Logic

ONS instruction fires but the OTE coil never latches in Studio 5000 because the one-shot is only true for one scan. Use OTL/OTU or seal-in logic instead.

Kinetix 5500 EtherNet/IP Network Switch Requirements and Topology

Configure Allen-Bradley Kinetix 5500 servo drives on EtherNet/IP. Covers CIP Sync, IEEE 1588 V2 timing, Stratix selection, DLR topology, and HMI.

Moving Average Filtering in DCS and PLC Analog Control

A moving-average filter is the sliding-window smoother most instrument engineers drop into DCS and PLC analog paths. Here is how the window works, how N and sample time set lag, and when a...

GE Mark VI Function Blocks for Gas Turbine Control Logic

On Frame 5–9 gas turbines, GE Mark VI and Mark VIe run control as function-block application software. This article maps process, protection, and sequencing functions—and what Toolbox ST access...