Description

The NKLS01-10 is a dedicated INFI-Net interface cable engineered to connect a Network Interface Slave (NIS) to a Network Termination Control Unit (NTCL) within Symphony Harmony INFI 90 control systems. This prefabricated cable assembly functions as a reliable physical data link to maintain uninterrupted communication across distributed control system (DCS) architectures. Encased in a durable polyvinyl chloride (PVC) sheath, the cable provides proper signal insulation and shielding required for structural network communication inside industrial automation environments.

Features

  • Pre-terminated connection setup ensuring secure installation and minimizing manual field wiring errors.
  • Wrapped in a high-grade polyvinyl chloride (PVC) insulation jacket to offer durability within industrial enclosures.
  • Explicitly configured to secure communication lines between network interface slave hardware and system termination points.

Applications

  • Symphony Harmony DCS Networks: Connects core communication cards to their corresponding terminal blocks.
  • Industrial Process Automation: Routes timing, control inputs, and diagnostics through specialized infrastructure lines.
  • Control Room Cabinet Interconnections: Bridging NIS modules directly with NTCL assemblies across multi-rack networks.

Technical Specifications

Parameter Value
Manufacturer ABB
Product ID NKLS01-10
ABB Type Designation NKLS01-10
Catalog Description INFI-Net Interface Cable - 10 Ft (Pvc)
Long Description Connect NIS to NTCL
Product Type Prefabricated_Cable
Customs Tariff Number 85444290
Cable Diameter 0.0635 mm
Product Net Depth / Length 63.5 mm
Product Net Height 292.1 mm
Product Net Width 292.1 mm
Product Net Weight 0 kg

Installation Guidelines

  • Disconnect all primary power tracking into the control cabinet before connecting or disconnecting any system communication cables.
  • Avoid routing the data cable parallel to heavy AC power distribution lines or frequency converter outputs to prevent signal distortion.
  • Observe structural cable bend radius guidelines during routing through cabinet ductwork to avoid damaging the internal conductors.
  • Verify that the terminal plugs are completely aligned and locked firmly into the interface ports on both the slave module and the termination block.

FAQ

What specific components does this cable link together?

The cable is specifically designed to establish a direct connection between a Network Interface Slave (NIS) and a Network Termination Control Unit (NTCL).

What material is used for the outer insulation of this assembly?

The cable features an outer protective jacket made of polyvinyl chloride (PVC) suitable for standard industrial application environments.

Does this communication line require manual field termination?

No, this is a prefabricated cable assembly that comes fully pre-terminated from the factory for immediate plug-and-play connection.

View all FAQs →

Product Documentation

Technical Datasheet (PDF) Complete specifications and technical drawings.

Technical Datasheet

ABB NKLS01-10 Symphony Harmony INFI-Net Interface Cable

Quantity
Shipping & Returns

Global Express Shipping

  • Standard Delivery: 4–6 business days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our technical warranty.
Reviews
1 of 3
Only 5 item(s) left in stock
Quantity
View full details

Global Express Shipping

  • Standard Delivery: 4-6 Business Days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries, including rapid delivery to Saudi Arabia and UAE.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our professional technical warranty.

Orders are processed and delivered Monday-Friday (excluding public holidays).


For full eligibility, restocking fees, and international return details, please view our official Refund & Return Policy .

TECHNICAL SPECIFICATIONS

Color pattern
Greyish White
Country of origin
Sweden

Technical knowledge

Moving TwinCAT 3 Licenses with C9900-L100: Build and Device Checks

Before moving a TwinCAT 3 license with a Beckhoff C9900-L100, verify the TwinCAT build, XML device description, exact order code and cabinet limits.

Replacing a Beckhoff EL4032: Wiring and Output Checks

A field checklist for replacing a Beckhoff EL4032, covering the ±10 V load, terminal map, power contacts, EtherCAT state, and watchdog behavior.

Replacing Yokogawa AAI835: Wiring and Barrier Checks Before Swap

Before replacing a Yokogawa AAI835, verify the 4-in/4-out channel map, power-loss loop behavior, barrier type, output load, cable, and redundancy.

ABB PM891K01 Replacement: Check Redundancy Before Ordering

ABB PM891K01 article 3BSE053241R1 is the non-redundant AC 800M processor kit. Use this field checklist before replacement.

ABB TP853 Replacement Checks for CI853/CI855/CI857/CI861

Replacement checks for ABB TP853 3BSE018126R1: identify the installed CI853, CI855, CI857, or CI861 interface, record wiring, and verify communication after installation.

5069-L330ERMS2 Startup Checks: RTBs, I/O, and Motion Limits

Engineering checks for the Allen-Bradley 5069-L330ERMS2: controller capacity, separate RTB kits, local I/O limits, network-node limits, and motion-axis count.