ABB

ABB NMBP-01 Modbus Plus Adapter Module

SKU NMBP-01

In stock
  • 12-month warranty
  • Free returns within 30 days
  • Manufacturer: ABB
  • Product No.: NMBP-01
  • Origin Sweden
  • Product Type: Modbus Plus adapter
  • Barcode: 8537101190
  • Payment: T/T, Western Union
  • Weight: 0.25 kg
  • Dimensions: 71 mm x 35 mm x 140 mm (H x W x D)
  • Shipping port: Xiamen
  • Warranty: 12 months

Tags

Product Documentation

Technical Datasheet (PDF) Complete specifications and technical drawings.

Technical Datasheet

ABB NMBP-01 Modbus Plus Adapter Module

Quantity

Product Description

The NMBP-01 is a fieldbus network connection interface designed to bridge variable speed drives directly into automated networks. This Modbus Plus Adapter Module acts exactly like a network node, establishing transparent communication for configuration, parameter modification, and high-speed feedback loop handling. The module features integrated dual-channel plastic fiber optic ports utilizing the Distributed Drives Communication System (DDCS) protocol to deliver localized electrical isolation between the logic circuit and power electronics. Engineered for critical environments, it enables control location command mapping, speed reference feeding, and direct parameter reads and writes via simulated holding register allocations.

Features

  • Seamless network device integration enabling full drive control mapping including start, stop, direction, and reference injection.
  • Dual physical layer interfaces featuring a standard 9-pin D-shell Modbus Plus fieldbus network connector and dedicated DDCS optical receivers and transmitters.
  • Global Data broadcasting capability supporting synchronous transfer up to 3 words of real-time control loop and feedback parameters.
  • Built-in local hardware diagnostics via specialized flashing Status LEDs and an integrated Modbus Plus network health indicator.
  • High-speed data update modes including an alternative fast architecture that bypasses standard logic counters to optimize processing times.

Applications

  • Variable speed motor drive coordination within large-scale Modicon Modbus Plus automation networks.
  • Multi-drive industrial configurations connecting up to 8 drives on a single token-passing segment.
  • Multi-level cross-network plant automation topologies spanning remote bridges and multiplexers.

Technical Specifications

Parameter Value
Manufacturer ABB
Model NMBP-01
Product Type Modbus Plus Adapter Module
Transmission Speed 1 MBit/s
DDCS Link Transfer Rate 4 Mbit/s
DDCS Medium Plastic core fiber optic cable, 1 mm diameter
DDCS Maximum Length 10 m between stations
Maximum Network Nodes 64 stations including bridges
Power Supply Input Regulated 24 VDC
Current Consumption 80 mA at 24 VDC
Degree of Protection IP 20
Enclosure Material Plastic
Operating Temperature 0 to +50 degC
Storage Temperature -40 to +70 degC
Operating Humidity 5 to 95% relative humidity, no condensation allowed
Maximum Operating Altitude 0 to 2000 m
Fast Transient Burst Immunity 4 kV 5/50 ns (IEC 801-4)
Product Net Height 71 mm
Product Net Width 35 mm
Product Net Depth 140 mm

Connections/Interfaces

Connector Pin Function
X2:1 Common
X2:2 B
X2:3 A
X2:4-9 NC (No Connection)
X1:1 +24 V Regulated VDC Power Input
X1:2 Gnd Shield Ground
X1:3 0 V Power Supply Common
V3 (Blue) DDCS Optical Link Receiver Port
V4 (Grey) DDCS Optical Link Transmitter Port

Installation Guidelines

  • Mechanical Mounting: Snap the device directly onto a standard DIN mounting rail inside or outside the cabinet space. Ensure a minimum free clearance of 10 mm from adjacent components or enclosure structural walls.
  • Electrical Safety: Isolate all primary drive electrical connections before handling the unit. Allow a minimum period of 5 minutes for internal capacitor banks to fully discharge.
  • Fiber Optic Handling: Maintain a strict minimum short-term fiber cable bend radius of 25 mm. Never exceed the long-term structural tensile load rating of 1 N.
  • Network Earthing: Ensure the entire Modbus Plus fieldbus network cable shield remains entirely isolated from external ground sources at every point. Connect the local segment shield line exclusively to terminal X1:2.
Shipping & Returns

Global Express Shipping

  • Standard Delivery: 4–6 business days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our technical warranty.
FAQ
What is the primary function of the module?
The device acts as an interface that connects specific industrial control drives directly to a Modbus Plus network system.
What power source specifications does the communication module require?
The hardware runs on a regulated 24 VDC power supply with an active current draw of approximately 80 mA.
What type of local diagnostics does the device provide?
The module features an integrated local Status LED and a Modbus Plus indicator that flash specific patterns to signal active operation states or hardware errors.
What are the environmental storage constraints for the hardware?
The unit must be stored in environments where temperatures stay between -40 degC and +70 degC with relative humidity below 95%.
Reviews

NMBP-01

Stock & lead time on request

Call
1 of 3

ABB NMBP-01 Modbus Plus Adapter Module

Only 5 item(s) left in stock
  • Manufacturer: ABB

  • Product No.: NMBP-01

  • Country of origin:Sweden

  • Product Type: Modbus Plus adapter

  • Barcode: 8537101190

  • Payment: T/T, Western Union

  • Weight: 250g

  • Dimensions: 71 mm x 35 mm x 140 mm (H x W x D)

  • Shipping port: Xiamen

  • Warranty: 12 months

Quantity
View full details

Product Description

The NMBP-01 is a fieldbus network connection interface designed to bridge variable speed drives directly into automated networks. This Modbus Plus Adapter Module acts exactly like a network node, establishing transparent communication for configuration, parameter modification, and high-speed feedback loop handling. The module features integrated dual-channel plastic fiber optic ports utilizing the Distributed Drives Communication System (DDCS) protocol to deliver localized electrical isolation between the logic circuit and power electronics. Engineered for critical environments, it enables control location command mapping, speed reference feeding, and direct parameter reads and writes via simulated holding register allocations.

Features

  • Seamless network device integration enabling full drive control mapping including start, stop, direction, and reference injection.
  • Dual physical layer interfaces featuring a standard 9-pin D-shell Modbus Plus fieldbus network connector and dedicated DDCS optical receivers and transmitters.
  • Global Data broadcasting capability supporting synchronous transfer up to 3 words of real-time control loop and feedback parameters.
  • Built-in local hardware diagnostics via specialized flashing Status LEDs and an integrated Modbus Plus network health indicator.
  • High-speed data update modes including an alternative fast architecture that bypasses standard logic counters to optimize processing times.

Applications

  • Variable speed motor drive coordination within large-scale Modicon Modbus Plus automation networks.
  • Multi-drive industrial configurations connecting up to 8 drives on a single token-passing segment.
  • Multi-level cross-network plant automation topologies spanning remote bridges and multiplexers.

Technical Specifications

Parameter Value
Manufacturer ABB
Model NMBP-01
Product Type Modbus Plus Adapter Module
Transmission Speed 1 MBit/s
DDCS Link Transfer Rate 4 Mbit/s
DDCS Medium Plastic core fiber optic cable, 1 mm diameter
DDCS Maximum Length 10 m between stations
Maximum Network Nodes 64 stations including bridges
Power Supply Input Regulated 24 VDC
Current Consumption 80 mA at 24 VDC
Degree of Protection IP 20
Enclosure Material Plastic
Operating Temperature 0 to +50 degC
Storage Temperature -40 to +70 degC
Operating Humidity 5 to 95% relative humidity, no condensation allowed
Maximum Operating Altitude 0 to 2000 m
Fast Transient Burst Immunity 4 kV 5/50 ns (IEC 801-4)
Product Net Height 71 mm
Product Net Width 35 mm
Product Net Depth 140 mm

Connections/Interfaces

Connector Pin Function
X2:1 Common
X2:2 B
X2:3 A
X2:4-9 NC (No Connection)
X1:1 +24 V Regulated VDC Power Input
X1:2 Gnd Shield Ground
X1:3 0 V Power Supply Common
V3 (Blue) DDCS Optical Link Receiver Port
V4 (Grey) DDCS Optical Link Transmitter Port

Installation Guidelines

  • Mechanical Mounting: Snap the device directly onto a standard DIN mounting rail inside or outside the cabinet space. Ensure a minimum free clearance of 10 mm from adjacent components or enclosure structural walls.
  • Electrical Safety: Isolate all primary drive electrical connections before handling the unit. Allow a minimum period of 5 minutes for internal capacitor banks to fully discharge.
  • Fiber Optic Handling: Maintain a strict minimum short-term fiber cable bend radius of 25 mm. Never exceed the long-term structural tensile load rating of 1 N.
  • Network Earthing: Ensure the entire Modbus Plus fieldbus network cable shield remains entirely isolated from external ground sources at every point. Connect the local segment shield line exclusively to terminal X1:2.

Product Documentation

Technical Datasheet (PDF) Complete specifications and technical drawings.

Technical Datasheet

ABB NMBP-01 Modbus Plus Adapter Module

What is the primary function of the module?

The device acts as an interface that connects specific industrial control drives directly to a Modbus Plus network system.

What power source specifications does the communication module require?

The hardware runs on a regulated 24 VDC power supply with an active current draw of approximately 80 mA.

What type of local diagnostics does the device provide?

The module features an integrated local Status LED and a Modbus Plus indicator that flash specific patterns to signal active operation states or hardware errors.

What are the environmental storage constraints for the hardware?

The unit must be stored in environments where temperatures stay between -40 degC and +70 degC with relative humidity below 95%.

Global Express Shipping

  • Standard Delivery: 4-6 Business Days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries, including rapid delivery to Saudi Arabia and UAE.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our professional technical warranty.

Orders are processed and delivered Monday-Friday (excluding public holidays).


For full eligibility, restocking fees, and international return details, please view our official Refund & Return Policy .

TECHNICAL SPECIFICATIONS

Color pattern
Green
Country of origin
Sweden
Power source
DC Power

Technical knowledge

Inside the PLC CPU: Scan Cycles, Memory, and Selection

A practical engineering guide to PLC CPU operation, from deterministic scan cycles and I/O image tables to memory, communications, diagnostics, redundancy, processor sizing, and reliable system...

1756-L73 Firmware Upgrade Guide: v19 vs v21/v31 Decision

Replacing a 1756-L73 does not automatically mean upgrading its firmware. This guide compares v19.013, v21.011 and v31.011, focusing on project compatibility, HMI communications, legacy networks and...

Implementing 3-Switch XOR Ladder Logic with Internal Bit

Implement a 3-SPST switch XOR light circuit in LogixPro or RSLogix 500 using an internal relay bit. Includes truth tables, boolean equations, and verified.

Building a Modbus RTU Network with CompactLogix and DeltaV

Integrate Allen-Bradley CompactLogix, Caterpillar ATS, and generators into DeltaV DCS over Modbus RTU. Covers ProSoft MVI69-MCM, Miille DIN266 gateways.

ONS Instruction Not Energizing OTE in Studio 5000 Ladder Logic

ONS instruction fires but the OTE coil never latches in Studio 5000 because the one-shot is only true for one scan. Use OTL/OTU or seal-in logic instead.

Kinetix 5500 EtherNet/IP Network Switch Requirements and Topology

Configure Allen-Bradley Kinetix 5500 servo drives on EtherNet/IP. Covers CIP Sync, IEEE 1588 V2 timing, Stratix selection, DLR topology, and HMI.