SKU PM862K02 3BSE081636R1

In stock
  • 12-month warranty
  • Free returns within 30 days
  • Manufacturer: ABB
  • Product No.: PM862K02 3BSE081636R1
  • Origin Switzerland
  • Product Type: AC 800M Controllers
  • Barcode: 8537101190
  • Payment: T/T, Western Union
  • Weight: 1.08 kg
  • Dimensions: 18.5 cm x 8.5 cm x 30.5 cm
  • Shipping port: Xiamen
  • Warranty: 12 months

Tags

Product Documentation

Technical Datasheet (PDF) Complete specifications and technical drawings.

Technical Datasheet

ABB PM862K02 3BSE081636R1 AC 800M Redundant Processor Unit

Quantity

Product Description

Description

The PM862K02 is a specialized hardware package featuring a Redundant Processor Unit designed to operate within the AC 800M controller system infrastructure. This controller hardware serves as a central computing and processing unit for large-scale industrial process control loop requirements. It supports multi-channel interface structures through its direct electrical ModuleBus, enabling connection to up to 12 S800 I/O units for processing varied digital and analog input/output data signals. Built for industrial process automation and distributed control networks, the module provides specialized onboard serial and Ethernet interfaces to achieve reliable point-to-point and network-wide industrial communications. The hardware platform is fully compatible with 800xA 6.0.2 system environments as well as Compact Control Builder 6.0.0-1 software versions and subsequent releases.

Features

  • Dual processor configuration containing two PM862 central processing units alongside twin TP830 baseplates for system uptime protection.
  • Integrated electrical ModuleBus framework allowing continuous data mapping with up to 12 localized S800 I/O blocks.
  • Built-in communication interfaces featuring dual Ethernet ports (CN1 and CN2) for broad network integration and an independent RS-232C serial link for dedicated service tool interactions.
  • Specialized Redundancy Control Link port integrated directly on the processor layout for dedicated runtime backup data synchronizations.
  • Non-volatile Compact Flash card reader interface provided to ensure quick loading of critical operational code and reliable cold retain variable storage.

Applications

The processing assembly is widely deployed for core automation tasks across:

  • 800xA System industrial operations requiring highly reliable controller architectures.
  • Compact Control Builder applications handling sophisticated logic handling and loop distribution configurations.
  • Critical infrastructure processes demanding redundant hardware tracking, automated CPU fallback procedures, and extensive field I/O expansion setups.

Ordering Information

Product ID ABB Type Designation Catalog Description
3BSE081636R1 PM862K02 PM862K02 Redundant Processor Unit

Technical Specifications

Parameter Value
Manufacturer ABB 
Product ID 3BSE081636R1 
ABB Type Designation PM862K02 
Product Type Central_Unit 
Processing Frequency 67 MHz 
Onboard Microprocessor MPC866 running at 133 MHz
Memory Capacity 32 MB SDRAM (RAM), 4 MB Flash PROM firmware storage
Power Dissipation 5.1 W typical / 8.6 W typical including full supply to ModuleBus and CEX-Bus
Current Consumption 210 mA typical (360 mA max.) excluding supply of ModuleBus and CEX-Bus
Power Supply Requirements 24 V nominal, variation between 19.2 V DC and 30 V DC
Redundant Power Supply Status Inputs Inputs designated SA, SB; Max input voltage 30 V
Power Reservoir Internal 5ms power reservoir for controlled power down
Protection Rating IP20 according to EN60529, IEC 529
Product Net Depth / Length 135 mm 
Product Net Height 186 mm 
Product Net Width 119 mm 
Product Net Weight 2.7 kg 
Number of Batteries
Battery Chemical Composition Lithium 
Battery Type Portable 
Battery Weight 9 g 
Customs Tariff Number 85371091 

Connections/Interfaces

Connector Pin Function
L+ / L- Power Input Connector Terminal (24 V DC Nominal Inputs)
SA / SB Redundant Power Supply Status Inputs (Max 30 V Input Limits)
CN1 / CN2 Ethernet Ports (IEEE 802.3, 10BaseT)
COM3 Serial Port (RS-232C) with Modem Support
COM4 Serial Port (RS-232C) for Service Tool Connection

Installation Guidelines

  • Module Assembly: Secure the dual baseplates cleanly before fitting the processor units onto the carrier frames to protect the underlying communication pins.
  • Power Connections: Wire the power distribution lines directly to the four-pin screw connector inputs using proper insulation and monitoring designated L+, L-, SA, and SB lines accurately.
  • Bus Termination: Always ensure that both ModuleBus terminators provided in the package are securely fitted to the end of the functional hardware train to maintain clear loop signals.
  • Battery Maintenance: Keep the dual portable memory backup batteries properly inserted into their designated retaining slots to guarantee long-term retain variable protection.

Compliance and Certifications

  • RoHS Information: Following EU Directive 2011/65/EU.
Shipping & Returns

Global Express Shipping

  • Standard Delivery: 4–6 business days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our technical warranty.
FAQ
What is included inside the standard commercial shipping package for this processor unit?
The package includes 2 pcs PM862 CPUs, 2 pcs TP830 baseplates, 2 pcs TB807 ModuleBus terminators, 1 pcs TK850 CEX-bus extension cable, 1 pcs TK851 RCU-Link cable, and 2 pcs memory backup batteries.
What are the specific requirements and parameters for the main power input connector?
The main power input consists of a four-pin screw connector mapping L+, L-, SA, and SB. It requires a nominal voltage input of 24 V DC, safely handling variations ranging between 19.2 V DC and 30 V DC.
What is the physical protection rating of the underlying controller housing?
The housing carries an IP20 physical protection rating in strict accordance with standard EN60529 and IEC 529 classifications.
Reviews

PM862K02 3BSE081636R1

Stock & lead time on request

Call
1 of 3

ABB PM862K02 3BSE081636R1 AC 800M Redundant Processor Unit

Only 8 item(s) left in stock
  • Manufacturer: ABB

  • Product No.: PM862K02 3BSE081636R1

  • Country of origin:Switzerland

  • Product Type: AC 800M Controllers

  • Barcode: 8537101190

  • Payment: T/T, Western Union

  • Weight: 1080g

  • Dimensions: 18.5 cm x 8.5 cm x 30.5 cm

  • Shipping port: Xiamen

  • Warranty: 12 months

Quantity
View full details

Description

The PM862K02 is a specialized hardware package featuring a Redundant Processor Unit designed to operate within the AC 800M controller system infrastructure. This controller hardware serves as a central computing and processing unit for large-scale industrial process control loop requirements. It supports multi-channel interface structures through its direct electrical ModuleBus, enabling connection to up to 12 S800 I/O units for processing varied digital and analog input/output data signals. Built for industrial process automation and distributed control networks, the module provides specialized onboard serial and Ethernet interfaces to achieve reliable point-to-point and network-wide industrial communications. The hardware platform is fully compatible with 800xA 6.0.2 system environments as well as Compact Control Builder 6.0.0-1 software versions and subsequent releases.

Features

  • Dual processor configuration containing two PM862 central processing units alongside twin TP830 baseplates for system uptime protection.
  • Integrated electrical ModuleBus framework allowing continuous data mapping with up to 12 localized S800 I/O blocks.
  • Built-in communication interfaces featuring dual Ethernet ports (CN1 and CN2) for broad network integration and an independent RS-232C serial link for dedicated service tool interactions.
  • Specialized Redundancy Control Link port integrated directly on the processor layout for dedicated runtime backup data synchronizations.
  • Non-volatile Compact Flash card reader interface provided to ensure quick loading of critical operational code and reliable cold retain variable storage.

Applications

The processing assembly is widely deployed for core automation tasks across:

  • 800xA System industrial operations requiring highly reliable controller architectures.
  • Compact Control Builder applications handling sophisticated logic handling and loop distribution configurations.
  • Critical infrastructure processes demanding redundant hardware tracking, automated CPU fallback procedures, and extensive field I/O expansion setups.

Ordering Information

Product ID ABB Type Designation Catalog Description
3BSE081636R1 PM862K02 PM862K02 Redundant Processor Unit

Technical Specifications

Parameter Value
Manufacturer ABB 
Product ID 3BSE081636R1 
ABB Type Designation PM862K02 
Product Type Central_Unit 
Processing Frequency 67 MHz 
Onboard Microprocessor MPC866 running at 133 MHz
Memory Capacity 32 MB SDRAM (RAM), 4 MB Flash PROM firmware storage
Power Dissipation 5.1 W typical / 8.6 W typical including full supply to ModuleBus and CEX-Bus
Current Consumption 210 mA typical (360 mA max.) excluding supply of ModuleBus and CEX-Bus
Power Supply Requirements 24 V nominal, variation between 19.2 V DC and 30 V DC
Redundant Power Supply Status Inputs Inputs designated SA, SB; Max input voltage 30 V
Power Reservoir Internal 5ms power reservoir for controlled power down
Protection Rating IP20 according to EN60529, IEC 529
Product Net Depth / Length 135 mm 
Product Net Height 186 mm 
Product Net Width 119 mm 
Product Net Weight 2.7 kg 
Number of Batteries
Battery Chemical Composition Lithium 
Battery Type Portable 
Battery Weight 9 g 
Customs Tariff Number 85371091 

Connections/Interfaces

Connector Pin Function
L+ / L- Power Input Connector Terminal (24 V DC Nominal Inputs)
SA / SB Redundant Power Supply Status Inputs (Max 30 V Input Limits)
CN1 / CN2 Ethernet Ports (IEEE 802.3, 10BaseT)
COM3 Serial Port (RS-232C) with Modem Support
COM4 Serial Port (RS-232C) for Service Tool Connection

Installation Guidelines

  • Module Assembly: Secure the dual baseplates cleanly before fitting the processor units onto the carrier frames to protect the underlying communication pins.
  • Power Connections: Wire the power distribution lines directly to the four-pin screw connector inputs using proper insulation and monitoring designated L+, L-, SA, and SB lines accurately.
  • Bus Termination: Always ensure that both ModuleBus terminators provided in the package are securely fitted to the end of the functional hardware train to maintain clear loop signals.
  • Battery Maintenance: Keep the dual portable memory backup batteries properly inserted into their designated retaining slots to guarantee long-term retain variable protection.

Compliance and Certifications

  • RoHS Information: Following EU Directive 2011/65/EU.

Product Documentation

Technical Datasheet (PDF) Complete specifications and technical drawings.

Technical Datasheet

ABB PM862K02 3BSE081636R1 AC 800M Redundant Processor Unit

What is included inside the standard commercial shipping package for this processor unit?

The package includes 2 pcs PM862 CPUs, 2 pcs TP830 baseplates, 2 pcs TB807 ModuleBus terminators, 1 pcs TK850 CEX-bus extension cable, 1 pcs TK851 RCU-Link cable, and 2 pcs memory backup batteries.

What are the specific requirements and parameters for the main power input connector?

The main power input consists of a four-pin screw connector mapping L+, L-, SA, and SB. It requires a nominal voltage input of 24 V DC, safely handling variations ranging between 19.2 V DC and 30 V DC.

What is the physical protection rating of the underlying controller housing?

The housing carries an IP20 physical protection rating in strict accordance with standard EN60529 and IEC 529 classifications.

Global Express Shipping

  • Standard Delivery: 4-6 Business Days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries, including rapid delivery to Saudi Arabia and UAE.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our professional technical warranty.

Orders are processed and delivered Monday-Friday (excluding public holidays).


For full eligibility, restocking fees, and international return details, please view our official Refund & Return Policy .

TECHNICAL SPECIFICATIONS

Country of origin
Switzerland

Recently Viewed Products

Technical knowledge

Implementing 3-Switch XOR Ladder Logic with Internal Bit

Implement a 3-SPST switch XOR light circuit in LogixPro or RSLogix 500 using an internal relay bit. Includes truth tables, boolean equations, and verified.

Building a Modbus RTU Network with CompactLogix and DeltaV

Integrate Allen-Bradley CompactLogix, Caterpillar ATS, and generators into DeltaV DCS over Modbus RTU. Covers ProSoft MVI69-MCM, Miille DIN266 gateways.

ONS Instruction Not Energizing OTE in Studio 5000 Ladder Logic

ONS instruction fires but the OTE coil never latches in Studio 5000 because the one-shot is only true for one scan. Use OTL/OTU or seal-in logic instead.

Kinetix 5500 EtherNet/IP Network Switch Requirements and Topology

Configure Allen-Bradley Kinetix 5500 servo drives on EtherNet/IP. Covers CIP Sync, IEEE 1588 V2 timing, Stratix selection, DLR topology, and HMI.

Moving Average Filtering in DCS and PLC Analog Control

A moving-average filter is the sliding-window smoother most instrument engineers drop into DCS and PLC analog paths. Here is how the window works, how N and sample time set lag, and when a...

GE Mark VI Function Blocks for Gas Turbine Control Logic

On Frame 5–9 gas turbines, GE Mark VI and Mark VIe run control as function-block application software. This article maps process, protection, and sequencing functions—and what Toolbox ST access...