ABB

ABB REB670 Relion 670 Series Busbar Protection Intelligent Electronic Device

SKU REB670

In stock
  • 12-month warranty
  • Free returns within 30 days
  • Manufacturer: ABB

  • Product No.: REB670

  • Country of origin:Sweden

  • Product Type: Busbar Protection IED

  • Barcode: 85371091

  • Payment: T/T, Western Union

  • Weight: 12000g

  • Dimensions: 242 mm x 266 mm x 449 mm (D x H x W)

  • Shipping port: Xiamen

  • Warranty: 12 months

Description

ABB REB670 is a busbar protection intelligent electronic device (IED) designed for the protection, control, and monitoring of busbars, T-connections, and meshed corners from medium to extra high voltage levels. This busbar protection IED provides selective, reliable, and fast fault clearance for all types of internal phase-to-phase and phase-to-earth faults in solidly earthed or low-impedance earthed power systems. It is also capable of handling internal multi-phase faults in isolated or high-impedance earthed power systems. Belonging to the Relion protection and control product family, the ABB REB670 implements the core design requirements of the IEC 61850 standard to deliver fully interoperable and future-proof substation automation applications.

Features

  • Extensive input/output capability supporting single, double, and triple busbar layouts with or without transfer bus arrangements.
  • Phase segregated measurement providing selective protection for complex substation layouts.
  • Integrated software-based dynamic Zone Selection for seamless adaptation to shifting substation topologies, such as one-and-a-half breaker stations, double breaker stations, and ring busbars.
  • Integrated check zone feature independent of disconnector positions to secure differential protection stability during improper status indications.
  • Efficient merging of differential zones during load-transfer conditions initiated by bus-sectionalizing disconnectors.
  • Built-in open CT detection and differential protection supervision to prevent unwanted operations during secondary circuit failures.
  • Advanced backup protection capabilities, including breaker failure protection, end fault protection, and overcurrent protection options.
  • Extensive protocol support covering IEC 61850-8-1, IEC 61850-9-2LE process bus, IEC 60870-5-103, DNP3.0, LON, and SPA protocols.

Applications

  • Single, double, and triple busbar configurations with or without transfer bus, double-circuit breaker, or one-and-a-half circuit breaker arrangements.
  • Substations requiring up to six differential zones and twenty-four analog current inputs.
  • High-voltage and extra-high-voltage utility and industrial substations utilizing isolated, high-impedance, low-impedance, or solidly earthed power networks.
  • Complex substation layouts utilizing dynamic zone selection, requiring large counts of binary and analog inputs/outputs.
  • Process-bus environments operating with sampled values according to the IEC 61850-9-2LE standard.

Ordering Information

Pre-configured Variant Phase Configuration Maximum Bay Capacity Differential Zones
REB670-A20 3-Phase 4 Bays 2 Zones
REB670-A31 3-Phase 8 Bays 2 Zones
REB670-B20 1-Phase 12 Bays 2 Zones
REB670-B21 1-Phase 12 Bays (Extendable to 24 CT inputs) 2 Zones
REB670-B31 1-Phase 24 Bays 2 Zones

Technical Specifications

Parameter Specification / Value
Manufacturer ABB / Hitachi Energy 
Product Version 2.2 
Rated Frequency 50 Hz / 60 Hz 
Operating Slope (Two-zone / Six-zone) Fixed at 53% 
Operating Slope (Four-zone) User settable among [0.53, 0.60, 0.65, 0.70, 0.75, 0.80, 0.85] 
Max Binary Inputs Up to 176 channels simultaneously activated 
Max Relay Outputs Up to 96 channels (Maximum 72 outputs simultaneously activated within nominal range) 
Auxiliary DC Supply Voltage 24-60 V DC ± 20%, 90-250 V DC ± 20% 
Voltage Ripple Influence Max 2% (Operative range), Full wave rectified 15% of EL 
DC Interruption Ride-Through 0-50 ms without restart 
Ambient Temperature (Operate Range) -25 degC to +55 degC 
Relative Humidity (Operative Range) 10-90% 
Transformer Input Combinations 12 inputs per galvanic separation module (Ring lug or compression type) 

Installation Guidelines

  • Grounding: Secure the IED case to the station earth using a low-impedance copper wire before making any electrical connections.
  • Shielding: Employ twisted-pair shielded cables for all binary signal lines and communication networks to reduce the effects of EMI/RFI noise.
  • Mounting: Install the unit into standard 19-inch racks or panel cutouts using the certified ABB mounting kit accessories.
  • Cooling and Ventilation: Maintain adequate clearance around the top and bottom of the enclosure to promote natural convection and prevent heat accumulation.
  • Cable Routing: Maintain clean separation between heavy-current primary cables, analog secondary transformer connections, and low-voltage digital signal wiring.
  • Polarity: Verify correctness of all auxiliary DC voltage wiring connections before energizing the IED power supply module.

Compliance and Certifications

  • Council of the European Communities Directive on Electromagnetic Compatibility (EMC Directive 2004/108/EC) 
  • Low-Voltage Directive (2006/95/EC) 
  • Product Standard EN 60255-26 (EMC requirements) 
  • Product Standards EN 60255-1 and EN 60255-27 (Low voltage requirements) 
  • International Standards of the IEC 60255 series

FAQ

What is the recommended operating temperature range for the device?

The recommended nominal ambient temperature range for operation is from -25 degC to +55 degC.

What auxiliary DC supply options are available for the device?

The device accommodates two auxiliary DC voltage ranges: 24-60 V DC and 90-250 V DC.

How many differential zones can the device support?

The device supports up to six differential protection zones depending on the selected configuration layout.

Which communication protocols are natively supported by the device?

The device supports communication via IEC 61850-8-1, IEC 61850-9-2LE, IEC 60870-5-103, DNP3.0, LON, and SPA protocols.

View all FAQs →

Product Documentation

Technical Datasheet (PDF) Complete specifications and technical drawings.

Technical Datasheet

ABB REB670 Relion 670 Series Busbar Protection Intelligent Electronic Device

Quantity
Shipping & Returns

Global Express Shipping

  • Standard Delivery: 4–6 business days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our technical warranty.
Reviews
1 of 1
Only 5 item(s) left in stock
Quantity
View full details

Global Express Shipping

  • Standard Delivery: 4-6 Business Days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries, including rapid delivery to Saudi Arabia and UAE.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our professional technical warranty.

Orders are processed and delivered Monday-Friday (excluding public holidays).


For full eligibility, restocking fees, and international return details, please view our official Refund & Return Policy .

Technical knowledge

1746-A7 Chassis Replacement Checks: Slots, Power and Interconnects

An engineering checklist for replacing an Allen-Bradley 1746-A7: verify chassis series, backplane loading, slot plan, interconnect cables, mounting, grounding and receiving condition.

IC200MDL650 Replacement Checks: Logic Polarity, Filters, and Commons

A field replacement guide for GE Fanuc IC200MDL650 covering revision-dependent negative logic, four common groups, 24 VDC thresholds, input filtering, carrier checks and commissioning records.

IC697CPX935 Replacement Checks: Memory, Ports, and Rack Power

A field-focused IC697CPX935 replacement guide covering fast memory, firmware-dependent serial behavior, rack power, cooling, I/O architecture and backup records.

IC693DSM324 Replacement Checks: FSSB, Firmware and Follower Control

A field-focused IC693DSM324 replacement guide covering Series 90-30 host checks, FSSB servo-chain records, 5 V power budget, firmware limits, follower control and commissioning.

HIMA F3430 Replacement Checks: Contact Ratings and Safety Limits

A field-focused HIMA F3430 replacement guide covering relay contact ratings, DC load derating, fusing, F3330/F3331 differences, safety restrictions and commissioning records.

IC697PWR710 Replacement Checks: Load Budget and Dual-Rack Limits

A field-focused IC697PWR710 replacement guide covering 5 V load calculations, dual-rack limits, extension cables, input checks, protection behavior and hardware revision risks.