ABB REB670 Relion 670 Series Busbar Protection Intelligent Electronic Device
SKU REB670
In stock
No reviews
12-month warranty
Free returns within 30 days
Manufacturer:
ABB
Product No.:
REB670
Country of origin:Sweden
Product Type:
Busbar Protection IED
Barcode:
85371091
Payment:
T/T, Western Union
Weight:
12000g
Dimensions:
242 mm x 266 mm x 449 mm (D x H x W)
Shipping port:
Xiamen
Warranty:
12 months
Description
ABB REB670 is a busbar protection intelligent electronic device (IED) designed for the protection, control, and monitoring of busbars, T-connections, and meshed corners from medium to extra high voltage levels. This busbar protection IED provides selective, reliable, and fast fault clearance for all types of internal phase-to-phase and phase-to-earth faults in solidly earthed or low-impedance earthed power systems. It is also capable of handling internal multi-phase faults in isolated or high-impedance earthed power systems. Belonging to the Relion protection and control product family, the ABB REB670 implements the core design requirements of the IEC 61850 standard to deliver fully interoperable and future-proof substation automation applications.
Features
Extensive input/output capability supporting single, double, and triple busbar layouts with or without transfer bus arrangements.
Phase segregated measurement providing selective protection for complex substation layouts.
Integrated software-based dynamic Zone Selection for seamless adaptation to shifting substation topologies, such as one-and-a-half breaker stations, double breaker stations, and ring busbars.
Integrated check zone feature independent of disconnector positions to secure differential protection stability during improper status indications.
Efficient merging of differential zones during load-transfer conditions initiated by bus-sectionalizing disconnectors.
Built-in open CT detection and differential protection supervision to prevent unwanted operations during secondary circuit failures.
Advanced backup protection capabilities, including breaker failure protection, end fault protection, and overcurrent protection options.
Extensive protocol support covering IEC 61850-8-1, IEC 61850-9-2LE process bus, IEC 60870-5-103, DNP3.0, LON, and SPA protocols.
Applications
Single, double, and triple busbar configurations with or without transfer bus, double-circuit breaker, or one-and-a-half circuit breaker arrangements.
Substations requiring up to six differential zones and twenty-four analog current inputs.
High-voltage and extra-high-voltage utility and industrial substations utilizing isolated, high-impedance, low-impedance, or solidly earthed power networks.
Complex substation layouts utilizing dynamic zone selection, requiring large counts of binary and analog inputs/outputs.
Process-bus environments operating with sampled values according to the IEC 61850-9-2LE standard.
Ordering Information
Pre-configured Variant
Phase Configuration
Maximum Bay Capacity
Differential Zones
REB670-A20
3-Phase
4 Bays
2 Zones
REB670-A31
3-Phase
8 Bays
2 Zones
REB670-B20
1-Phase
12 Bays
2 Zones
REB670-B21
1-Phase
12 Bays (Extendable to 24 CT inputs)
2 Zones
REB670-B31
1-Phase
24 Bays
2 Zones
Technical Specifications
Parameter
Specification / Value
Manufacturer
ABB / Hitachi Energy
Product Version
2.2
Rated Frequency
50 Hz / 60 Hz
Operating Slope (Two-zone / Six-zone)
Fixed at 53%
Operating Slope (Four-zone)
User settable among [0.53, 0.60, 0.65, 0.70, 0.75, 0.80, 0.85]
Max Binary Inputs
Up to 176 channels simultaneously activated
Max Relay Outputs
Up to 96 channels (Maximum 72 outputs simultaneously activated within nominal range)
Auxiliary DC Supply Voltage
24-60 V DC ± 20%, 90-250 V DC ± 20%
Voltage Ripple Influence
Max 2% (Operative range), Full wave rectified 15% of EL
DC Interruption Ride-Through
0-50 ms without restart
Ambient Temperature (Operate Range)
-25 degC to +55 degC
Relative Humidity (Operative Range)
10-90%
Transformer Input Combinations
12 inputs per galvanic separation module (Ring lug or compression type)
Installation Guidelines
Grounding: Secure the IED case to the station earth using a low-impedance copper wire before making any electrical connections.
Shielding: Employ twisted-pair shielded cables for all binary signal lines and communication networks to reduce the effects of EMI/RFI noise.
Mounting: Install the unit into standard 19-inch racks or panel cutouts using the certified ABB mounting kit accessories.
Cooling and Ventilation: Maintain adequate clearance around the top and bottom of the enclosure to promote natural convection and prevent heat accumulation.
Cable Routing: Maintain clean separation between heavy-current primary cables, analog secondary transformer connections, and low-voltage digital signal wiring.
Polarity: Verify correctness of all auxiliary DC voltage wiring connections before energizing the IED power supply module.
Compliance and Certifications
Council of the European Communities Directive on Electromagnetic Compatibility (EMC Directive 2004/108/EC)
Low-Voltage Directive (2006/95/EC)
Product Standard EN 60255-26 (EMC requirements)
Product Standards EN 60255-1 and EN 60255-27 (Low voltage requirements)
International Standards of the IEC 60255 series
FAQ
What is the recommended operating temperature range for the device?
The recommended nominal ambient temperature range for operation is from -25 degC to +55 degC.
What auxiliary DC supply options are available for the device?
The device accommodates two auxiliary DC voltage ranges: 24-60 V DC and 90-250 V DC.
How many differential zones can the device support?
The device supports up to six differential protection zones depending on the selected configuration layout.
Which communication protocols are natively supported by the device?
The device supports communication via IEC 61850-8-1, IEC 61850-9-2LE, IEC 60870-5-103, DNP3.0, LON, and SPA protocols.