The ABB TC630 3BSE002253R1 is an Advant Fieldbus 100 optical modem designed for signal conversion between coaxial and optical cables within Advant Master and MOD 300 control systems. Built to interface with Advant Controllers such as AC110, AC160, AC410, AC450, and S800 I/O systems, the modem facilitates Advant Fieldbus 100 communication across optical fiber infrastructure. Operating on a 24V D.C. power supply, the unit interfaces with ST-style optical connectors and supports 2 x 65.5/125 um or 100/400 um optical fibers.

Features

  • Facilitates conversion for Advant Fieldbus 100 coaxial/optical or optical/coaxial cable configurations.
  • Powered by a 24V D.C. power supply.
  • Features ST-style optical connectors.
  • Compatible with 2 x 65.5/125 um and 100/400 um optical fiber sizes.
  • Categorized as a small equipment communication module under WEEE directive standards.

Applications

  • Advant Fieldbus 100 (AF 100) optical network signal conversion.
  • Advant Controller systems including AC 110, AC 160, AC 410, AC 450, and AC 450RMC.
  • Integration with S800 I/O communication networks.
  • Advant OCS with Master SW and MOD 300 SW process control applications.

Ordering Information

Product ID Type Designation Description
3BSE002253R1 TC630 TC630 AF 100 Optical Modem

Technical Specifications

Parameter Specification
Manufacturer ABB
Product ID 3BSE002253R1
Type Designation TC630
Product Type Communication Module
Power Supply 24V D.C.
Communication Bus Advant Fieldbus 100
Connector Type ST-style
Optical Fiber Compatibility 2 x 65.5/125 um or 100/400 um
Dimensions (H x W x D) 11 mm x 65 mm x 47 mm
Weight 0.715 kg
Customs Tariff Number / HS Code 85176200 / 851762

Installation Guidelines

  • Ensure the 24V D.C. power supply is properly connected and within spec before powering the module.
  • Connect ST-style fiber optic connectors carefully to protect fiber end faces from contamination.
  • Verify that the optical fiber specifications match 2 x 65.5/125 um or 100/400 um requirements.
  • Secure signal cabling to prevent strain on coaxial and optical connector ports.

FAQ

What is the ABB 3BSE002253R1 TC630 used for?

The ABB 3BSE002253R1 TC630 is an AF 100 optical modem used to convert coaxial and optical cable signals on the Advant Fieldbus 100 network.

What power supply voltage does the TC630 optical modem require?

The TC630 optical modem requires a 24V D.C. power supply.

Which connector and fiber types are compatible with the ABB 3BSE002253R1?

The module uses ST-style connectors and supports 2 x 65.5/125 um or 100/400 um optical fiber.

Which control systems support the TC630 modem?

The module is compatible with Advant OCS systems, including Advant Controllers 110, 160, 410, and 450, as well as S800 I/O communication networks.

View all FAQs →

Product Documentation

Technical Datasheet (PDF) Complete specifications and technical drawings.

Technical Datasheet

ABB TC630 3BSE002253R1 AF 100 Optical Modem

Quantity
Shipping & Returns

Global Express Shipping

  • Standard Delivery: 4–6 business days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our technical warranty.
Reviews
1 of 4
Only 5 item(s) left in stock
Quantity
View full details

Global Express Shipping

  • Standard Delivery: 4-6 Business Days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries, including rapid delivery to Saudi Arabia and UAE.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our professional technical warranty.

Orders are processed and delivered Monday-Friday (excluding public holidays).


For full eligibility, restocking fees, and international return details, please view our official Refund & Return Policy .

TECHNICAL SPECIFICATIONS

Country of origin
Sweden

Technical knowledge

1746-A7 Chassis Replacement Checks: Slots, Power and Interconnects

An engineering checklist for replacing an Allen-Bradley 1746-A7: verify chassis series, backplane loading, slot plan, interconnect cables, mounting, grounding and receiving condition.

IC200MDL650 Replacement Checks: Logic Polarity, Filters, and Commons

A field replacement guide for GE Fanuc IC200MDL650 covering revision-dependent negative logic, four common groups, 24 VDC thresholds, input filtering, carrier checks and commissioning records.

IC697CPX935 Replacement Checks: Memory, Ports, and Rack Power

A field-focused IC697CPX935 replacement guide covering fast memory, firmware-dependent serial behavior, rack power, cooling, I/O architecture and backup records.

IC693DSM324 Replacement Checks: FSSB, Firmware and Follower Control

A field-focused IC693DSM324 replacement guide covering Series 90-30 host checks, FSSB servo-chain records, 5 V power budget, firmware limits, follower control and commissioning.

HIMA F3430 Replacement Checks: Contact Ratings and Safety Limits

A field-focused HIMA F3430 replacement guide covering relay contact ratings, DC load derating, fusing, F3330/F3331 differences, safety restrictions and commissioning records.

IC697PWR710 Replacement Checks: Load Budget and Dual-Rack Limits

A field-focused IC697PWR710 replacement guide covering 5 V load calculations, dual-rack limits, extension cables, input checks, protection behavior and hardware revision risks.