Allen-Bradley

Allen-Bradley 1747-L553 SLC 5/05 Controller 64K Memory

SKU 1747-L553

In stock
  • 12-month warranty
  • Free returns within 30 days
  • Manufacturer: Allen-Bradley

  • Product No.: 1747-L553

  • Country of origin:Singapore

  • Product Type: Programmable Logic Controllers

  • Payment: T/T, Western Union

  • Weight: 450g

  • Dimensions: 145 x 35 x 130 mm

  • Shipping port: Xiamen

  • Warranty: 12 months

Description

The Allen-Bradley 1747-L553 is an SLC 5/05 modular processor unit designed for medium-to-large programmable logic controller (PLC) applications within the 1746 SLC system architecture. Featuring 64 KB of user memory, this high-capacity controller executes ladder logic and communication routines, offering execution times as fast as 0.37 µs for bit instructions and a typical program scan time of 0.9 ms per kilobyte. The processor installs directly into slot 0 (the leftmost position) of any standard 1746 chassis, interfacing with up to 3 local chassis and managing up to 30 slots.

Equipped with dual integrated communication ports, the 1747-L553 provides Channel 1 Ethernet TCP/IP connectivity along with a Channel 0 RS-232 serial interface. Channel 1 allows seamless plant-floor networking via standard 10Base-T Ethernet cabling, enabling high-speed peer-to-peer messaging, data acquisition, and programming connection through network hubs. Channel 0 supports versatile point-to-point and multi-drop serial configurations, including DF1 Full-Duplex, DF1 Half-Duplex master/slave, DH-485, and ASCII protocols.

The module includes integrated RAM backed up by a replaceable lithium battery (Catalog Number 1747-BA), which preserves volatile program data during power loss. An internal capacitor maintains power to the RAM for at least 30 minutes during a battery swap, preventing program corruption. For permanent, non-volatile storage, the processor supports optional Flash EPROM memory modules.

Features

  • 64 KB User Memory: Provides expanded capacity for complex ladder programming, data storage, and status file tracking.
  • High-Speed Logic Execution: Achieves 0.37 µs bit execution time (XIC) and a program scan time of 0.9 ms/K.
  • Integrated Ethernet Channel: Channel 1 features 10Base-T Ethernet TCP/IP communication for high-speed network integration.
  • Multiprotocol Serial Channel: Channel 0 RS-232 port supports DF1 Full-Duplex, DF1 Half-Duplex, DH-485, and ASCII protocols.
  • Large I/O System Capacity: Supports up to 4096 discrete inputs and 4096 discrete outputs across a 3-chassis local system (up to 30 total slots).
  • Diagnostic Status LEDs: Front-panel LEDs provide clear status indication for Power, Run, Fault (FLT), Battery (BATT), Force, Ethernet (ENET), and RS232 channels.
  • 30-Minute Backup Capacitor: Keeps RAM energized for at least 30 minutes during battery maintenance without loss of system data.

Applications

  • Automated Assembly & Material Handling: Manages multi-axis sequencing, conveyor lines, and high-speed data transfer to supervisory systems over Ethernet.
  • Process Control Systems: Handles discrete and analog loops across multiple chassis setups with up to 4,096 discrete I/O points.
  • Remote Monitoring & Control: Utilizes standard TCP/IP networking to communicate with plant-wide SCADA and HMI platforms.
  • Legacy System Upgrades: Replaces smaller 16 KB or 32 KB SLC 5/05 processors (such as 1747-L551 or 1747-L552) to expand ladder program capacity without hardware re-engineering.

Technical Specifications

Parameter Specification
Manufacturer Allen-Bradley / Rockwell Automation
Model Identifier 1747-L553
Product Family SLC 500 / 1746 System
Processor Type SLC 5/05 Controller
User Memory 64K Words / 64 KB
Maximum Discrete I/O 4096 Inputs / 4096 Outputs
Maximum Local System Expansion 3 Chassis / 30 Slots
Bit Execution Time (XIC) 0.37 µs
Typical Program Scan Time 0.9 ms per K
Backplane Current at 5V DC 1.0 A
Backplane Current at 24V DC 0 mA
Channel 1 Communication Ethernet TCP/IP (10Base-T)
Channel 0 Communication RS-232 (DF1 Full-Duplex, DF1 Half-Duplex, DH-485, ASCII)
Network Addressing IP address set via RS-232 connection
Programming Software RSLogix 500
Memory Backup Option Replaceable Lithium Battery (1747-BA); Optional Flash EPROM (1747-M11, 1747-M12, 1747-M13)
Memory Retention (Without Battery) Minimum 30 minutes via internal capacitor
Program Scan Hold-up Time 20 ms to 3 s (power supply loading dependent)
Operating Temperature 0 to +60 degC (+32 to +140 degF)
Storage Temperature -40 to +85 degC (-40 to +185 degF)
Relative Humidity 5 to 95% non-condensing
Vibration Resistance 0.015 in peak-to-peak displacement at 5-57 Hz; 2.5Gs acceleration at 57-2000 Hz
Operating Shock 30Gs
Noise Immunity NEMA Standard ICS 2-230
Country of Origin Singapore

Connections / Interfaces

Interface Port Cable / Connector Requirement Supported Protocols / Function
Channel 1 (Ethernet) 10Base-T Cable via RJ45 / Hub Ethernet TCP/IP high-speed network communication
Channel 0 (Serial) 1747-CP3 Cable or 1784-PCMK / KTX Card RS-232: DF1 Full-Duplex (19.2K baud default), DF1 Half-Duplex, DH-485, ASCII

Installation Guidelines

  1. Safety Verification: Ensure power to the 1746 chassis power supply is completely switched OFF before inserting or removing the processor.
  2. Electrostatic Precautions: Handle the controller by its plastic housing to avoid static discharge, which can damage onboard electronics or clear RAM memory.
  3. Chassis Insertion: Slide the processor into Slot 0 (the far-left slot) of the 1746 chassis until the top and bottom retainer clips snap securely in place.
  4. Protective Wrap: Remove the protective shipping wrap from the module housing after physical installation into the chassis.
  5. Power-On Verification: Turn on the chassis power supply (1746-P1 through 1746-P7 series). Confirm that the power supply POWER LED illuminates and the controller FLT (Fault) LED flashes initially.

Configuration and Maintenance Guidelines

Initial Network Configuration

  1. Connect a 1747-CP3 serial cable between Channel 0 of the processor and your computer's COM port.
  2. Open RSLogix 500 and configure DF1 Full-Duplex serial driver defaults (19.2K baud, no parity, CRC error check).
  3. Assign the required static IP address, subnet mask, and gateway settings to Channel 1 (Ethernet) over the RS-232 serial connection.
  4. Connect Channel 1 to your 10Base-T Ethernet network hub or switch to enable high-speed ladder upload/download and network messaging.

Battery Maintenance

  • Low Battery Warning: Replace the lithium battery (Cat. No. 1747-BA) when the red BATT LED illuminates on the front panel.
  • RAM Backup Hold Time: An onboard capacitor holds memory intact for at least 30 minutes after the battery is disconnected.
  • Replacement Procedure: Turn off power, release the chassis clips, slide out the processor, unplug the old battery connector from its socket, clip the new 1747-BA battery in place, plug in the connector, and re-install the processor in slot 0.

Compliance and Certifications

  • UL Listed
  • CSA Approved
  • Class 1, Groups A, B, C, or D, Division 2 Hazardous Locations
  • CE Compliant (all applicable directives)

FAQ

How do I configure the Ethernet IP address on an SLC 5/05 1747-L553 processor?

The initial Ethernet IP address for Channel 1 on the 1747-L553 controller must be assigned via an RS-232 serial connection on Channel 0 using RSLogix 500 or BOOTP services. Once the serial connection is established, network parameters are written to the controller configuration.

Will I lose my ladder logic program when replacing the 1747-BA battery on a 1747-L553?

No, the processor features an integrated capacitor that maintains RAM contents for at least 30 minutes while the battery is disconnected. As long as the battery replacement is completed within this 30-minute window, the ladder logic program and data files remain intact.

Which slot in the 1746 chassis must the 1747-L553 controller occupy?

The 1747-L553 processor must always be installed in Slot 0, which is the leftmost slot of the primary 1746 modular chassis directly adjacent to the power supply unit.

Can I upgrade from a 1747-L551 or 1747-L552 to a 1747-L553 processor?

Yes, the 1747-L553 is hardware and form-factor identical to other SLC 5/05 processors in the 1746 platform, providing a seamless drop-in upgrade path to expand user memory to 64 KB without changing chassis or power supplies.

View all FAQs →

Product Documentation

Technical Datasheet (PDF) Complete specifications and technical drawings.

Technical Datasheet

Allen-Bradley 1747-L553 SLC 5/05 Controller 64K Memory

Quantity
Shipping & Returns

Global Express Shipping

  • Standard Delivery: 4–6 business days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our technical warranty.
Reviews
1 of 3
Only 10 item(s) left in stock
Quantity
View full details

Global Express Shipping

  • Standard Delivery: 4-6 Business Days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries, including rapid delivery to Saudi Arabia and UAE.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our professional technical warranty.

Orders are processed and delivered Monday-Friday (excluding public holidays).


For full eligibility, restocking fees, and international return details, please view our official Refund & Return Policy .

TECHNICAL SPECIFICATIONS

Country of origin
Singapore

Technical knowledge

IC693CPU360 vs IC693CPU364: Ethernet and Power Budget

Compare the IC693CPU360 and IC693CPU364 by Ethernet interface, +5 VDC load, memory, rack limits, and replacement checks.

1756-OF4 Output Wrong? Check Mode, RTB, and Scaling First

A field-first diagnostic sequence for 1756-OF4 analog output problems: channel mode, removable terminal block, scaling, and controlled electrical checks.

1746-OA8 vs 1746-OA16: Output Count and Current Limits

A direct comparison of 1746-OA8 and 1746-OA16 output count, common grouping, backplane current and temperature-derated load limits.

Replacing a 1761-NET-DNI: Capture These Settings First

A field checklist for recording the 1761-NET-DNI hardware series, firmware, EDS file, DF1 settings, DeviceNet address and messaging configuration before replacement.

EL3062 vs EL3062-0030: The Input Range Changes

The EL3062 is a 0–10 V EtherCAT terminal. The EL3062-0030 is a 0–30 V variant. This checklist covers identification, scaling and commissioning.

Replacing a 1769-OW8: Checks Before Moving Relay Loads

A field checklist for replacing Allen-Bradley 1769-OW8 relay output modules without losing load-group, wiring, and commissioning details.