The Allen-Bradley 1756-L55M16 is a ControlLogix5555 programmable automation controller designed for chassis-based industrial control applications. This unit features an integrated 1756-M16 memory board providing 1.5 MB of data and logic memory capacity. Positioned in any slot of a ControlLogix chassis, the 1756-L55M16 manages sequential, process, motion, and drive control tasks while providing built-in serial RS-232 communication capability for workstation interface and system diagnostics.
Features
Equipped with a 1756-M16 memory board providing 1.5 MB of memory.
Integrates a front-panel RS-232 serial communication port.
Supports insertion and removal under power (RIUP) within the chassis backplane.
Features front status indicators including RUN, I/O, FORCE, RS232, BAT, and OK.
Includes a 3-position front keyswitch for selecting RUN, REM, and PROG modes.
Applications
Industrial automation control systems
Sequential and process control execution
Chassis-based ControlLogix system architecture
Technical Specifications
Specification
Value
Model
1756-L55M16
Controller Family
ControlLogix5555
Included Memory Board
1756-M16
Data and Logic Memory
1.5 MB
Nonvolatile Memory
No
Backplane Current @ 5.1V DC
1.23 A
Backplane Current @ 24V DC
0.014 A
Power Dissipation
5.6 W
Thermal Dissipation
19.1 BTU/hr
Operating Temperature
0 to 60 degC (32 to 140 degF)
Storage Temperature
-40 to 85 degC (-40 to 185 degF)
Relative Humidity
5 to 95% noncondensing
Vibration
2 g @ 10 to 500 Hz
Operating Shock
30 g
Nonoperating Shock
50 g
ESD Immunity
6 kV contact discharges, 8 kV air discharges
Radiated RF Immunity
10V/m (80 to 2000 MHz), 1V/m (2.0 to 2.7 GHz)
EFT/B Immunity
±4 kV at 5 kHz on communications ports
Surge Transient Immunity
±2 kV line earth (CM) on communications ports
Conducted RF Immunity
10V rms with 1 kHz sine-wave 80% AM (150 kHz to 80 MHz)
Isolation Voltage
30V continuous, Basic Insulation Type, RS232 to system
Replacement Battery
1756-BA1
Enclosure Type Rating
None (open style)
North American Temp Code
T4A
IEC Temp Code
T4
Weight
Approx. 0.35 kg (12.5 oz)
Connections/Interfaces
Connector Pin
Function
Pin 1
DCD (Data Carrier Detect)
Pin 2
RXD (Receive Data)
Pin 3
TXD (Transmit Data)
Pin 4
DTR (Data Terminal Ready)
Pin 5
GND (Ground)
Pin 6
DSR (Data Set Ready)
Pin 7
RTS (Request to Send)
Pin 8
CTS (Clear to Send)
Pin 9
N/C (Not Connected)
Installation Guidelines
Chassis Mounting: Align the module circuit board with top and bottom chassis guides and slide into any slot until latches engage flush.
Static Safeguards: Wear a grounded wriststrap and avoid touching circuit components or connector pins during handling.
Battery Maintenance: Connect only a 1756-BA1 battery or 1756-BATM battery module to maintain memory power when chassis power is removed.
Serial Cabling: Limit custom RS-232 cable lengths to 15.2 m (50 ft) and connect the cable shield at both connector ends.
Power/Hazard Precautions: Ensure power is removed or the location is nonhazardous prior to inserting/removing the controller or connecting serial cabling.
Compliance and Certifications
UL Listed Industrial Control Equipment (File E65584)
CSA Certified Process Control Equipment (File LR54689C)
CSA Certified Process Control Equipment for Class I, Division 2 Group A,B,C,D Hazardous Locations (File LR69960C)
CE Compliance (EMC Directive 2004/108/IEC: EN 61326-1, EN 61000-6-2, EN 61000-6-4, EN 61131-2)
C-Tick Compliant (AS/NZS CISPR 11)
EEx ATEX Directive 94/9/EC Compliant (EN 60079-15, Zone 2)
FAQ
What memory board is installed on this controller?
This unit comes equipped with an integrated 1756-M16 memory board providing 1.5 MB of data and logic memory.
Which replacement battery should be used with the controller?
The controller uses a 1756-BA1 battery or a 1756-BATM battery module to maintain internal memory power.
What programming cable is compatible with the serial port?
The serial port supports communication via a 1756-CP3 or 1747-CP3 serial cable.
A practical replacement guide for the GE Fanuc IC693CPU313, covering its embedded five-slot architecture, memory backup, firmware-dependent capacity and why it cannot use Series 90-30 expansion racks.
A field-focused comparison of Bently Nevada 3500/40M and 3500/42M monitor inputs, channel-pair configuration, rear I/O options, external termination hardware and firmware checks before replacement.
A field checklist for diagnosing Allen-Bradley 1746-NR4 RTD and resistance inputs, including sensor curves, lead compensation, excitation current, filter timing and channel diagnostics.
A field-focused checklist for replacing an Allen-Bradley 1785-L40B or planning a PLC-5/40 migration, covering backups, 1771 I/O mapping, DH+/RIO channels, revision risks and commissioning.
Replacing an Allen-Bradley 1747-SN scanner? Check SLC 500 logical rack and G-file mapping, link speed, cable termination, COMM/FAULT LEDs and hardware series before blaming the module or changing the...