The Allen-Bradley 1785-ME32 is a non-volatile EEPROM Memory Module manufactured by Rockwell Automation for the PLC-5 programmable controller platform. This specialized expansion device acts as an independent program backup carrier, providing 32 Kilowords of dedicated memory capacity to safeguard operating logic, configuration parameters, and data table files against complete power loss or primary system failures. The module is engineered to fit into standard PLC-5 processors, enabling users to upload code images from processor RAM or restore functional application routines directly to active controller memory during diagnostic recovery procedures. Housed in a compact, slide-in form factor, the 1785-ME32 eliminates the risk of memory corruption due to dead internal chassis batteries, delivering an extra layer of structural stability for localized industrial automation environments.
Features
Secure non-volatile program backup memory tailored for standard PLC-5 control systems.
32 Kilowords of high-density EEPROM storage capable of holding complete operational profiles and ladder execution code.
Direct software-driven transmission path supporting fast image transfers between active processor memory and the storage card.
Auxiliary retention strategy ensuring reliable system recovery independent of lithium battery conditions.
Applications
Long-term non-volatile storage and backup for critical process control application code.
Rapid recovery deployments inside automated manufacturing facilities experiencing sustained power outages or control faults.
Standardized logic replication across multiple equivalent processing hardware nodes.
Technical Specifications
Parameter
Specification
Manufacturer
Allen-Bradley / Rockwell Automation
Model Number
1785-ME32
Product Line
PLC-5
Module Type
Memory Device (EEPROM)
Memory Capacity
32 Kilowords
Function
Program Backup
Weight
0.19 lbs (0.09 kg)
Installation Guidelines
Processor Power Clearance: Prior to introducing or removing the memory card module, confirm all input electrical power feeding the local I/O chassis and processor assembly has been disconnected to isolate the internal electrical bus lines.
Backplane Switch Configuration: Verify backplane hardware settings align with memory integration needs; if a processor expects a memory module but none is present, or if indicators are mismatched, the device logs fault code 82.
Electrostatic Grounding Safety: Ground your workspace appropriately and wear a functional static dissipation wrist strap while picking up the unit to protect sensitive solid-state components from electrostatic damage.
FAQ
What is the primary function of this memory storage device?
The module provides non-volatile EEPROM storage to act as an external program backup, preserving ladder programs and parameters in case the main controller power drops out.
What memory size configuration does this hardware component offer?
The device features a memory density of 32 Kilowords dedicated to application backup tracking.
What minor fault or error occurs if backplane options are set incorrectly for a memory module?
The controller triggers a fault code 82 if configuration parameters are set to expect a module but no memory device is seated, or if there is an illegal cartridge type mismatch.
A practical commissioning sequence for KEPServerEX OPC UA connections: define data ownership, test tags locally, configure endpoint and certificate trust, limit access, then verify failure recovery...
Commissioning an Ethernet-connected PLC often starts with the laptop, not the controller. Learn how to record existing settings, choose a temporary address, test connectivity, and restore the plant...
Combustible dust controls require more than alarms. Learn how to map dust generation, select instrumentation, design interlocks, handle failed feedback, test safe states, and maintain the full...
Hairpin windings raise slot fill and support compact traction motors, but conductor geometry, AC losses, insulation damage, weld quality, and cooling determine whether the design meets its targets.
Use Ansible to standardize SCADA server changes without expanding OT risk. This guide covers inventories, idempotent playbooks, staged testing, credentials, logging, and practical rollback controls.
A VPN encrypts the path to an industrial network, but secure remote PLC work also needs identity controls, segmented access, change approval, logging, safe operating boundaries, and tested recovery...
Choosing a selection results in a full page refresh.