1 of 1

B&R X20DI9371 X20 High-Density Digital Input Module

B&R X20DI9371 X20 High-Density Digital Input Module

Only 10 item(s) left in stock
  • Manufacturer: B&R

  • Product No.: X20DI9371

  • Country of origin:United States

  • Product Type: X20 Digital Input Module

  • Payment: T/T, Western Union

  • Weight: 2000g

  • Shipping port: Xiamen

  • Warranty: 12 months

Quantity
View full details

Process Monitoring Overview

The B&R X20DI9371 (X20DI9371) is a high-density 12-channel discrete sensor interface module designed for the modular B&R X20 control platform. Operating within high-throughput automation networks like automated picking lines, metal stamping presses, and continuous food processing lines, this module captures field-level status changes. By processing real-time telemetry from proximity sensors, safety limit switches, and pushbuttons, the unit ensures responsive signal transmission to the central processor, minimizing control-loop latency and preventing sequence timing faults.

Circuit Architecture and Filter Dynamics

This digital module features 12 input channels configured for space-saving 1-wire connection topologies. Designed with a sink (NPN) input circuit layout conforming to EN 61131-2 Type 1 standards, each channel exhibits a typical input resistance of 6.4 kΩ and draws 3.75 mA at nominal 24 VDC. To suppress electrical contact bounce and shop-floor inductive noise, the module incorporates a dual-stage filtering system: an ultra-fast hardware filter operating at ≤100 μs combined with a software-defined filter adjustable from 0 to 25 ms in precise 0.2 ms steps.

Technical Performance Matrix

Core Parameter Operational Specification
Model X20DI9371
Brand B&R Automation
Origin Austria
Input Density 12 digital inputs
Circuit Configuration Sink (NPN layout)
Wiring Design 1-wire connection topology
Standard Classification EN 61131-2 Type 1 characteristics
Nominal Input Voltage 24 VDC (-15% / +20% operating window)
Input Current (at 24 VDC) Typ. 3.75 mA per channel
Input Input Resistance Typ. 6.4 kΩ
Hardware Filter Interval ≤100 μs
Software Filter Range 0 to 25 ms (Default setting 1 ms)
Bus Power Consumption 0.18 W
Internal I/O Power Draw 1.75 W
Weight 0.08 kg (Net) / 2.0 kg (Shipping gross)

Industrial Maintenance and FAQs

How do you clear a channel that shows false positive transitions in an environment with high electromagnetic noise?

Access the module's I/O configuration window inside B&R Automation Studio. Increase the default 1 ms software filter time upward in 0.2 ms increments (up to 25 ms) to mask high-frequency induced voltage spikes. If false triggering continues, inspect the physical routing of the sensor cable and verify that the proximity switch matches the 6.4 kΩ sink interface requirements.

Can a standard sourcing (PNP) 3-wire sensor be connected directly to this input module?

No. The X20DI9371 utilizes a sink configuration, meaning the input terminal requires the field device to switch the negative (0 VDC) side of the circuit to register an active state. Connecting a standard sourcing PNP sensor (which outputs 24 VDC) directly will not complete the circuit path. Use an NPN sensor or install an external interposing relay to invert the signal.

Is separate power distribution wiring required for 1-wire connection layouts?

Yes. Because a 1-wire connection means only the active signal wire returns directly to the module terminal block, the external sensors must receive their 24 VDC supply voltage from a separate potential distribution block, such as an X20PD potential distribution card located within the same rack segment.


Field Commissioning and Wiring Guidelines

  • Common Reference Potential Tracking: Ensure the external 24 VDC power supply powering the field sensors shares a common 0 VDC reference ground with the X20 rack. Without a unified ground reference, the NPN sink inputs cannot form a complete electrical path back through the 6.4 kΩ internal resistor, leading to erratic signal states or complete input failure.

  • High-Speed Signal Isolation: When utilizing the fast hardware filter properties (≤100 μs), shield all incoming pulse wires. Route these discrete signal lines completely away from heavy three-phase AC power lines and variable frequency drive output cables to prevent cross-talk from generating false state counts.

  • Terminal Module Seating Constraints: Ensure the combined power profile—specifically the 0.18 W bus draw and 1.75 W internal I/O load—is included in the local bus segment's total thermal calculation. Before locking the module onto the DIN rail, verify that the base alignment tabs match adjacent modules precisely to prevent pin distortion on the internal backplane bus.

 

Global Express Shipping

  • Standard Delivery: 4-6 Business Days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries, including rapid delivery to Saudi Arabia and UAE.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our professional technical warranty.

Orders are processed and delivered Monday-Friday (excluding public holidays).


For full eligibility, restocking fees, and international return details, please view our official Refund & Return Policy .

TECHNICAL SPECIFICATIONS

Color pattern
Greyish White
Country of origin
United States
Power source
DC Power

Recently Viewed Products

Technical knowledge

Guide to Robotic Grippers: From Delicate Handling to Heavy-Duty Automation

Modern robotic grippers are evolving beyond traditional mechanical jaws. From gecko-inspired adhesive systems and soft food-grade grippers to AI-powered warehouse tools, advanced gripping...

Throwback: How Early Electric Motors Changed Underground Mining

From rope-driven DC compressors to battery-powered mine carts, early mining operations marked a turning point in industrial electrification. This article explores how electric motors transformed...

Factory I/O: A Modern PLC Simulation Tool for Industrial Automation Training

Factory I/O is transforming PLC education by delivering immersive 3D industrial simulations for students, engineers, and maintenance teams. The platform bridges the gap between theory and real-world...

Programming Single-Axis Motion Cycles on a CMZ Servo Drive

This tutorial examines how onboard PLC functionality inside a CMZ SBD servo drive can execute standalone motion programs, including homing logic, position control, and cyclic axis movement without an...

Single-Axis Motion Control Setup with CMZ Servo Drives

This tutorial explores the commissioning of a single-axis servo motion system using a CMZ SBD drive, covering hardware setup, axis scaling, homing configuration, and safe motion verification for...

Mitsubishi FX PLC Integration With FR-D700 VFD and HMI Control

This tutorial explains how Mitsubishi FX PLCs integrate with FR-D700 VFDs and HMI panels for forward/reverse motor control. It covers wiring logic, parameter configuration, ladder programming, and...