B&R

B&R X20DI9372 Digital Input Module 12-Channel

SKU X20DI9372

In stock
  • 12-month warranty
  • Free returns within 30 days
  • Manufacturer: B&R

  • Product No.: X20DI9372

  • Country of origin:United States

  • Product Type: 12 digital inputs 24 VDC for 1-wire connections

  • Payment: T/T, Western Union

  • Weight: 1500g

  • Shipping port: Xiamen

  • Warranty: 12 months

Product Overview

The X20DI9372 (X20DI9372) is a high-density digital input module within the B&R X20 System, featuring 12 channels designed for 24 VDC 1-wire connections. This module is an essential component for capturing discrete signals from sensors, switches, and proximity probes in industrial automation environments. Engineered for efficiency and space-saving, the X20DI9372 is widely utilized in high-speed packaging lines, assembly automation, and general machine control. Its fast hardware input filter and configurable software filtering ensure reliable signal detection even in electrically noisy environments, minimizing the risk of false triggers and improving overall system stability.

Technical Configuration

The module architecture focuses on high-speed response times and flexible signal processing to accommodate various industrial sensor types.

  • 1-Wire Connectivity: Optimized for 1-wire connection technology, allowing for high-density wiring and reduced cabinet space requirements.

  • Dual-Stage Filtering: Features a fixed hardware filter ($\le 100$ $\mu$s) for rapid pulse detection and a software filter configurable from $0$ to $25$ ms (in $0.2$ ms steps) to tune out contact bounce or EMI.

  • Precision Switching Thresholds: Operates with clearly defined logic levels (Low $< 5$ VDC; High $> 15$ VDC) to ensure compatibility with standard 24 VDC industrial sensors and PLC outputs.

  • Power Management: Consumes only $0.18$ W from the system bus, with an internal I/O consumption of $1.75$ W, maintaining low thermal output within the X20 slice.

Technical Specifications

Feature Details
Model X20DI9372
Brand B&R Industrial Automation
Inputs 12 Digital Inputs
Connection Type 1-wire
Nominal Voltage 24 VDC
Input Voltage Range 20.4 to 28.8 VDC (-15% / +20%)
Hardware Filter $\le 100$ $\mu$s
Software Filter 0 to 25 ms (Configurable)
Switching Threshold Low $< 5$ VDC, High $> 15$ VDC
Protection Rating IP20
Shipping Weight 1.5 kg

FAQs

What is meant by "1-wire connection" for this module?

In the X20 system context, a 1-wire connection means the module provides the input terminal for the signal wire only. The common ground (GND) or sensor power must be provided by a separate potential distribution module or through the terminal block's internal bus if applicable.

How do I adjust the input filter time for specific sensors?

The software filter is configured via the hardware configuration tree in B&R Automation Studio. The default setting is 1 ms, but it can be adjusted in 0.2 ms increments to match the switching characteristics of your specific hardware.

Can this module detect very high-speed pulses?

With a hardware filter of $\le 100$ $\mu$s, the module can detect pulses in the kilohertz range. For extremely high-speed counting or encoder applications, a dedicated counter module (like the X20DC series) is typically recommended.


Engineering Guidelines and Wiring Standards

  • Potential Distribution: Since this is a 1-wire module, ensure that the return path (0 VDC) for your sensors is correctly tied to the same potential as the X20 system power supply. Using an X20PD potential distribution module adjacent to the DI module is standard practice for organized wiring.

  • Signal Integrity: For signal lines exceeding 10 meters, use shielded twisted-pair cabling to prevent inductive coupling from nearby AC power lines. The shield should be grounded at the entry point of the control cabinet.

  • Terminal Block Compatibility: The X20DI9372 requires a 12-pin terminal block (e.g., X20TB12). Ensure the block is fully seated and the locking levers are engaged to prevent intermittent signal loss due to vibration.

  • Maintenance: Periodically check the diagnostic LEDs on the module faceplate. A steady green "Run" LED indicates normal operation, while the individual channel LEDs provide immediate visual verification of the input logic state during commissioning and troubleshooting.

 

Quantity
Shipping &amp; Returns

Global Express Shipping

  • Standard Delivery: 4–6 business days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our technical warranty.
Reviews
1 of 1
Only 10 item(s) left in stock
Quantity
View full details

Global Express Shipping

  • Standard Delivery: 4-6 Business Days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries, including rapid delivery to Saudi Arabia and UAE.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our professional technical warranty.

Orders are processed and delivered Monday-Friday (excluding public holidays).


For full eligibility, restocking fees, and international return details, please view our official Refund & Return Policy .

TECHNICAL SPECIFICATIONS

Color pattern
Greyish White
Country of origin
United States
Power source
DC Power

Technical knowledge

Derivative Action in PID Control Without Noise Problems

Learn what derivative action contributes to a PID loop, why it can amplify measurement noise and setpoint changes, and how filtering, sampling, and staged tests make D tuning safer.

Designing Industrial Networks That Stay Troubleshootable

A practical guide to segmenting, documenting, and testing industrial Ethernet networks so plant teams can isolate faults quickly, control change, and expand without creating fragile dependencies.

Commissioning IO-Link From Master Ports to IODD Data

Commission IO-Link systematically from master addressing and port modes through IODD selection, PLC byte mapping, parameter backups, device validation, and failure-injection tests.

PowerFlex Dynamic Braking Resistor Design and Testing

A practical PowerFlex braking guide covering regenerative energy, resistor resistance and duty cycle, thermal protection, model-specific parameters, and measured commissioning tests.

Engineering Industrial Joystick Controls for Safe Motion

An industrial joystick is only the first element in a safe motion command chain. This guide covers sensing choices, wiring, signal validation, PLC logic, restart behavior, and commissioning for...

Seeing PID Behavior Before Tuning the Loop

PID tuning becomes safer when engineers can see how proportional, integral, and derivative actions reshape error, output, and response over time. This guide turns live trends into a disciplined...