Engineering Logix Produced and Consumed Tags
A field-ready guide to Logix produced and consumed tags, covering data contracts, RPI selection, connection status, stale-data handling, commissioning and controller-to-controller troubleshooting.
Manufacturer: Basler Electric
Product No.: DECS-200-1L
Country of origin:United States
Product Type: Digital Excitation Control Systems
Payment: T/T, Western Union
Weight: 6350g
Dimensions: 304 mm x 205 mm x 171 mm (H x W x D)
Shipping port: Xiamen
Warranty: 12 months
The Basler Electric DECS-200-1L Digital Excitation Control System provides precision excitation control for synchronous generators by regulating the direct current applied to the generator exciter field. Equipped with a pulse width modulated (PWM) power stage, the system delivers high performance across non-linear load applications and supports output capabilities of 32 Vdc, 63 Vdc, or 125 Vdc at up to 15 Adc. Operating modes include Automatic Voltage Regulation (AVR) with 0.25% accuracy, Field Current Regulation (FCR/Manual mode), Var control, and Power Factor (PF) control.
The controller features true RMS single- or three-phase sensing for generator voltage, bus voltage matching, and generator current. Interface options consist of contact inputs, proportional ±10 Vdc or 4–20 mA inputs, a front-panel RS-232 port (COM0), a side RS-232 port for unit autotracking (COM1), and a side RS-485 port supporting Modbus RTU protocol (COM2). Integrated machine protection capabilities include generator overvoltage/undervoltage, field overvoltage/overcurrent, loss of sensing, loss of field, exciter diode monitoring (EDM), and overexcitation/underexcitation limiting.
| Model | Tracking Option | Power Supply Option |
|---|---|---|
| DECS-200-1L | 1 (Internal autotracking) | L (24/48 Vdc) |
| Parameter | Specification |
|---|---|
| Manufacturer | Basler Electric |
| Model | DECS-200-1L |
| Control Power Input | 16-60 Vdc (24/48 Vdc nominal, Style L), Burden = 30 W |
| AC Operating Power Input (32 Vdc Output) | 60 Vac nominal (56-70 Vac +/-10%), 1 or 3 phase, 50-500 Hz, 780 VA burden |
| AC Operating Power Input (63 Vdc Output) | 120 Vac nominal (100-139 Vac +/-10%), 1 or 3 phase, 50-500 Hz, 1570 VA burden |
| AC Operating Power Input (125 Vdc Output) | 240 Vac nominal (190-277 Vac +/-10%), 1 or 3 phase, 50-500 Hz, 3070 VA burden |
| Rated Continuous Field Voltage Output | 32 Vdc, 63 Vdc, or 125 Vdc |
| Rated Continuous Field Current Output | 15 Adc |
| Rated 10-Second Forcing Voltage Output | 50 Vdc (32 Vdc mode), 100 Vdc (63 Vdc mode), 200 Vdc (125 Vdc mode) |
| Rated 10-Second Forcing Current Output | 30 Adc |
| Minimum Field Resistance | 2.13 Ohms (32 Vdc), 4.2 Ohms (63 Vdc), 8.3 Ohms (125 Vdc) |
| Generator Voltage Sensing Input | 1 or 3 phase, ranges: 100V/50Hz (85-127V), 120V/60Hz (94-153V), 200V/50Hz (170-254V), 240V/60Hz (187-305V), 400V/50Hz (340-508V), 480V/60Hz (374-600V), 500V/50Hz (425-625V), 600V/60Hz (510-660V); Burden < 0.1 VA/phase |
| Bus Voltage Sensing Input | 1 phase, ranges: 100V/50Hz (85-127V), 120V/60Hz (94-153V), 200V/50Hz (170-254V), 240V/60Hz (187-305V), 400V/50Hz (340-508V), 480V/60Hz (374-600V), 500V/50Hz (425-625V), 600V/60Hz (510-660V) |
| Generator Current Sensing Input | 1A and 5A AC ranges ( metering/control & cross current compensation); Burden < 1 VA |
| Contact Inputs | 11 dry contact switching inputs supplied with 24 Vdc |
| Analog Remote Set Point Inputs | Selectable +/-10 Vdc or 4-20 mA |
| Contact Outputs | Resistive: 7.0 A at 24 Vdc, 0.7 A at 48 Vdc, 0.2 A at 125 Vdc, 7.0 A at 120/240 Vac |
| AVR Regulation Accuracy | +/-0.25% over load range at rated power factor |
| Operating Temperature | -40 degC to +60 degC (-40 degF to +140 degF) |
| Storage Temperature | -40 degC to +85 degC (-40 degF to +185 degF) |
| Salt Fog | Per MIL-STD-810E, Method 509.3 (100 hrs salt fog, 100 hrs drying) |
| Shock | 15 Gs in three mutually perpendicular planes |
| Vibration | 5-26Hz: 1.2Gs; 27-52Hz: 0.914mm double amplitude; 53-500Hz: 5.0Gs |
| Dimensions (H x W x D) | 304 mm x 205 mm x 171 mm (12.0 in x 8.08 in x 6.76 in) |
| Weight | 6.35 kg (14 lbs) |
| Connector Pin | Function |
|---|---|
| BATT+ (B7) | DC Control Power Input (+24/48 Vdc) |
| BATT- (B8) | DC Control Power Input (-24/48 Vdc) |
| L (B9) | AC Control Power Input Line |
| N (B10) | AC Control Power Input Neutral |
| C (C4), B (C3), A (C2), GND (C1) | Input Operating Power Connections and Chassis Ground |
| E1 (A1), E2 (A2), E3 (A3) | Voltage Sensing Inputs |
| CTB 1AMP (B1), CTB 5AMP (B2), CTB COM (B3) | Current Sensing Channel B |
| CTCC 1AMP (B4), CTCC 5AMP (B5), CTCC COM (B6) | Cross Current Compensation Sensing Channel |
| A5, B3, A4, B1 | Bus Voltage Matching Inputs |
| F+ (C5), F- (C6) | Exciter Field Power Output |
| A6, A7 | 4-20 mAdc Auxiliary Analog Input |
| A8, A9, A10 | +/-10 Vdc Auxiliary Analog Input (GND, V+, V-) |
| A11, A12 | Stop/Start Relay Contacts |
| A13, A14 | Watchdog Relay Contacts |
| A15, A16 | Programmable Output Relay #1 |
| A17, A18 | Programmable Output Relay #2 |
| A19, A20 | Programmable Output Relay #3 |
| A21, A22 | Start Contact Input and Common |
| A23, A24 | Stop Contact Input and Common |
| A25, A26 | AVR Mode Select Contact Input and Common |
| A27, A28 | FCR Mode Select Contact Input and Common |
| A29, A30 | Raise Contact Input and Common |
| A31, A32 | Lower Contact Input and Common |
| A33, A34 | Pre-position Contact Input and Common |
| A35, A36 | Unit/Parallel Operation Contact Input and Common |
| A37, A38 | Var/PF Control Contact Input and Common |
| A39, A40 | Secondary Unit Enable Contact Input and Common |
| A41, A42 | Alarm Reset Contact Input and Common |
| A43, A44, A45 | RS-485 Communication Output Port COM2 (A, B, C) |
| COM0 (Front Panel) | RS-232 9-pin Sub-D Serial Port for local PC interface |
| COM1 (Side Panel) | RS-232 9-pin Sub-D Serial Port for dual unit autotracking |