BECKHOFF CP6601-0000-0020 Built-in Panel PC

SKU CP6601-0000-0020

In stock
  • 12-month warranty
  • Free returns within 30 days
  • Manufacturer: BECKHOFF

  • Product No.: CP6601-0000-0020

  • Country of origin:Germany

  • Product Type: Built-in Panel PCs

  • Payment: T/T, Western Union

  • Weight: 500g

  • Shipping port: Xiamen

  • Warranty: 12 months

Description

The BECKHOFF CP6601-0000-0020 is a compact, fanless Built-in Panel PC designed for high-efficiency machine-level control, monitoring, and HMI visualization tasks. This industrial-grade controller seamlessly integrates a high-quality 12-inch TFT display with an SVGA resolution of 800 x 600 pixels and a resistive single-finger touch screen, providing an intuitive, dependable physical interface for operators in rugged environment setups.

At the core of the processor unit is an ARM Cortex-A8 processor running at 1 GHz, mounted on a 3½-inch motherboard. Outfitted with 1 GB DDR3 RAM and a dedicated microSD slot for expandable solid-state flash memory, the system provides responsive local execution. To ensure data security in volatile industrial environments, the controller features 128 KB of non-volatile NOVRAM for persistent parameter storage during sudden power interruptions.

The mechanical build is engineered for panel-mount deployment, featuring a robust aluminum front with a sheet-steel rear cover. Installation is streamlined via integrated, pull-out clamping levers that eliminate loose mounting components. Connectivity options include on-board Ethernet and dedicated EtherCAT ports alongside dual USB 2.0 and serial interfaces, making the hardware versatile and ready for modern industrial communication architectures.

Features

  • Low-power ARM Cortex-A8 1 GHz processor for reliable, fanless continuous operation.
  • 12-inch SVGA TFT display with single-finger resistive touch control.
  • 1 GB DDR3 system memory and dedicated microSD storage card slot.
  • 128 KB NOVRAM non-volatile memory to prevent critical data loss.
  • Dual network architecture featuring 10/100BASE-T Ethernet and on-board EtherCAT interface.
  • Integrated 1-second UPS powered by the main 24 V DC supply.
  • Rugged IP65-rated aluminum front panel with IP20-rated sheet-steel rear enclosure.

Applications

  • Machine-level visualization and local HMI control interfaces.
  • Distributed PLC control nodes using TwinCAT runtime architectures.
  • Real-time motion control and network master interfacing via EtherCAT.
  • Embedded data acquisition and protocol gateway routing.

Technical Specifications

General

Manufacturer BECKHOFF
Model CP6601-0000-0020
Device Type Built-in Panel PC
Operating System Windows Embedded Compact 7 (English)

Performance & Processing

Processor ARM Cortex-A8, 1 GHz
Motherboard 3½-inch motherboard
System Memory 1 GB DDR3 RAM
Persistent Memory 128 KB NOVRAM
Storage Slots 1 x microSD slot

Display & Interface

Display Size 12-inch TFT
Resolution 800 x 600 pixels (SVGA)
Touch Technology Resistive single-finger touch screen
Front Keyboard Front laminate without keys, display only

Electrical & Connectivity

Supply Voltage 24 V DC
Uninterruptible Power Supply Integrated 1-second UPS
Ethernet Ports 1 x 10/100BASE-T (on-board)
EtherCAT Ports 1 x EtherCAT interface (on-board)
USB Ports 2 x USB 2.0
Serial Interface 1 x RS232

Mechanical & Environmental

Housing Material Aluminum front with sheet-steel rear cover
Protection Rating Front side IP65, rear side IP20
Mounting Method Pull-out clamping levers
Operating Temperature 0 to 55 degC

Installation Guidelines

  1. Ensure all electrical supplies are fully de-energized before mounting or servicing the Panel PC.
  2. Prepare the control cabinet cutout in strict compliance with the dimensions specified for the 12-inch display enclosure.
  3. Carefully insert the Panel PC into the front of the cutout, checking that the outer sealing gasket lies completely flat against the mounting plate to preserve the IP65 seal.
  4. Slide and lock the built-in pull-out clamping levers from the rear to secure the device without loose mounting screws.
  5. Connect the 24 V DC power cable to the specified supply terminal block, verifying correct polarity.
  6. Connect the network, USB, and serial interfaces using shielded cables designed to mitigate electromagnetic interference.
  7. Verify system grounding by establishing a direct connection between the chassis ground terminal and the main control cabinet backplane.

FAQ

What is the pre-installed operating system on the CP6601-0000-0020?

The BECKHOFF CP6601-0000-0020 Built-in Panel PC comes pre-installed with the Windows Embedded Compact 7 (English) operating system, which is optimized for TwinCAT runtime applications.

How does the CP6601-0000-0020 protect against data loss during sudden power failures?

The BECKHOFF CP6601-0000-0020 utilizes an integrated 1-second UPS powered by the 24 V DC supply, which works alongside 128 KB of non-volatile NOVRAM to store critical system state variables and prevent loss of data.

What is the front-panel sealing rating for this model?

The BECKHOFF CP6601-0000-0020 features an IP65 protection rating on the front panel when flush-mounted in a control cabinet cutout, protecting it from dust and liquid spray, while the rear side has an IP20 protection rating.

What physical connection options are integrated on the CP6601-0000-0020?

The BECKHOFF CP6601-0000-0020 provides one 10/100BASE-T Ethernet port, one dedicated EtherCAT port, two USB 2.0 ports, one RS232 serial port, and a single slot for microSD flash storage.

Does this Panel PC require loose brackets or screws for cabinet mounting?

No, the BECKHOFF CP6601-0000-0020 features built-in, pull-out clamping levers that slide out to clamp against the rear of the cabinet cutout, enabling fast and secure installation without loose parts.

View all FAQs →

Quantity
Shipping & Returns

Global Express Shipping

  • Standard Delivery: 4–6 business days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our technical warranty.
Reviews
1 of 1
Only 10 item(s) left in stock
Quantity
View full details

Global Express Shipping

  • Standard Delivery: 4-6 Business Days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries, including rapid delivery to Saudi Arabia and UAE.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our professional technical warranty.

Orders are processed and delivered Monday-Friday (excluding public holidays).


For full eligibility, restocking fees, and international return details, please view our official Refund & Return Policy .

TECHNICAL SPECIFICATIONS

Country of origin
Germany

Technical knowledge

Allen-Bradley 1771-IG: TTL Logic and 5 V Wiring Checks

Check 1771-IG TTL HIGH/LOW logic thresholds, field supply ripple and 1771-WC wiring before replacing an input module.

AKS 33 vs AKS 3000: Checks Before Replacing a Pressure Transmitter

A field checklist for distinguishing Danfoss 060G2105, 060G1323 and 060G2109 by pressure range, fitting, loop signal and controller scaling.

Diagnosing DeltaV SE5009 Power Problems Before Replacement

A field checklist for separating 24 VDC input, carrier bus, output derating and alarm-contact faults before replacing an Emerson SE5009.

Commissioning Quantum Inputs with the 140XSM00200 Simulator

A controlled commissioning method for using the 140XSM00200 simulator to verify Modicon Quantum input mapping and interlocks before reconnecting field wiring.

Commissioning PLX32-EIP-MBTCP: Subnets, Registers, and RPI

A commissioning checklist for the ProSoft PLX32-EIP-MBTCP covering subnet separation, register contracts, EtherNet/IP timing, failure tests and replacement records.

Diagnosing IC693MDL916 Relay Outputs Before Module Replacement

A field checklist for IC693MDL916 relay commands, terminal blocks, load current, switching rate and contact-side measurements.