Description
Designed for demanding, high-performance automation tasks, the CX2042-N031-0002 serves as a robust basic CPU module within the modular Beckhoff CX2000 Embedded PC family. Utilizing multi-core processing power, this industrial controller is engineered to handle complex TwinCAT real-time control, PLC, NC, and CNC applications with high precision. This specific hardware variant integrates the -N031 system interface option, providing an RS485 serial communication port configured via a 9-pin D-sub socket. Engineered as a drop-point configuration without echo and with termination switched off, it allows for direct integration with legacy serial devices and serial fieldbus systems within the cabinet.
Features
- Equipped with high-performance multi-core processing architecture for real-time automation.
- Integrated -N031 interface providing a dedicated RS485 communication channel.
- 9-pin D-sub interface configured as a drop point (no echo, termination disabled) for direct network integration.
- Modular expandability via direct connection to EtherCAT Terminals (EL/ES) or Bus Terminals (KL/KS).
- Robust, industrial-grade housing designed to withstand vibration and temperature fluctuations in control environments.
Applications
- Complex CNC, PLC, and motion control systems in manufacturing.
- Central control nodes for distributed fieldbus networks.
- Industrial process monitoring and data acquisition systems.
- Upgrade paths for legacy installations requiring RS485 serial integration.
Technical Specifications
| Manufacturer |
Beckhoff Automation |
| Part Number / Model |
CX2042-N031-0002 |
| Series |
CX2000 Embedded PC |
| Module Type |
Basic CPU Module |
| Interface Option |
-N031 (RS485 interface) |
| Connection Type |
9-pin D-sub socket |
| Interface Configuration |
Drop point, without echo, termination off |
| System Bus Connection |
Direct connection to Beckhoff I/O terminals (EtherCAT) |
| Shipping Weight |
3.0 kg |
Connections and Interfaces
| Interface Type |
Specification / Pinout |
Configuration Settings |
| RS485 |
9-pin D-sub female socket |
Drop point configuration |
| Echo Mode |
Disabled (Without echo) |
Internal loopback off |
| Termination |
Switched Off |
External termination required if acting as network end-node |
Installation Guidelines
-
Mounting: Snap onto standard 35 mm DIN rail (EN 60715) within a horizontal installation position.
-
Ventilation: Maintain standard physical clearance above and below the CPU module to facilitate heat dissipation.
-
Grounding: Ensure a low-impedance electrical connection between the CPU module backplane and the DIN rail.
-
Shielding: Use high-quality shielded twisted-pair (STP) cabling for the RS485 interface to prevent electromagnetic interference (EMI).