BECKHOFF

BECKHOFF CX2100-0024 CX2000 Power Supply Module

SKU CX2100-0024

In stock
  • 12-month warranty
  • Free returns within 30 days
  • Manufacturer: BECKHOFF

  • Product No.: CX2100-0024

  • Country of origin:Germany

  • Product Type: Power Supply Modules

  • Payment: T/T, Western Union

  • Weight: 650g

  • Dimensions: 60 mm x 100 mm x 91 mm

  • Shipping port: Xiamen

  • Warranty: 12 months

Description

Engineered for modular integration within complex control systems, the BECKHOFF CX2100-0024 is a robust 240 W power supply module designed specifically to power CX20xx series Embedded PCs. This module serves as the central power interface, offering galvanic isolation and automatic recognition of the connected backplane bus system, whether using E-bus (EtherCAT) or K-bus (Bus Terminals).

The CX2100-0024 features Uninterruptible Power Supply (UPS) capabilities utilizing One Cable Technology (OCT) via a 24 V DC connection to the CU81xx series. Additionally, an illuminated front-panel FSTN display with 2 lines of 16 characters provides real-time diagnostic readouts and status information directly on the unit, optimizing onsite troubleshooting and system monitoring.

Features

  • Delivers up to 240 W of continuous power output to the CX20xx system.
  • Automatic bus recognition supports seamless switching between E-bus and K-bus technologies.
  • UPS OCT-capable interface enables streamlined communication and power backup integration with CU81xx devices.
  • Integrated 2-line x 16-character illuminated FSTN display for direct localized diagnostics.
  • Spring-loaded terminal connection system for reliable, vibration-resistant wiring.

Applications

  • Heavy industrial automation and process control systems using Beckhoff Embedded PCs.
  • Power plant and distribution control systems requiring integrated UPS functionality.
  • High-vibration manufacturing environments requiring secure spring-terminal connections.

Technical Specifications

Manufacturer Beckhoff Automation
Model / Part Number CX2100-0024
Input Voltage 24 V DC (-15 % / +20 %), electrically isolated
Max. Power Output 240 W
Max. Power Consumption 22 W
I/O Bus Support E-bus (EtherCAT) or K-bus (Bus Terminals), automatic recognition
Current Supply E-bus/K-bus 2 A
UPS Interface UPS OCT communication to CU81xx via 24 V DC cable
Connection Technology Spring-loaded technique (adapter terminal)
Display Type FSTN display, 2 lines x 16 characters, illuminated
Status Indicators 1 x PWR LED, 1 x I/O Run LED, 1 x I/O Err LED
Dimensions (W x H x D) 60 mm x 100 mm x 91 mm
Weight Approx. 650 g
Operating Temperature -25 to +60 degC
Storage Temperature -25 to +85 degC
Relative Humidity 95 %, non-condensing
Vibration/Shock Resistance Conforms to EN 60068-2-6 / EN 60068-2-27
EMC Immunity/Emission Conforms to EN 61000-6-2 / EN 61000-6-4
Protection Rating IP20

Installation Guidelines

The CX2100-0024 module is designed for standard DIN rail mounting as part of a modular CX20xx system block. Secure the module firmly onto the rail alongside the Embedded PC module. Ensure that wiring is completed using the spring-loaded adapter terminals to guarantee vibration-resistant contacts. Maintain appropriate clearance inside the control cabinet to facilitate passive ventilation and comply with the specified ambient operating temperature range of -25 to +60 degC.

Compliance and Certifications

  • CE
  • UL

FAQ

What is the primary function of the Beckhoff CX2100-0024?

The CX2100-0024 is a 240 W power supply module designed to power the CX20xx series of Embedded PCs while automatically managing and recognizing connection to E-bus (EtherCAT) or K-bus backplanes.

What does UPS OCT-capable mean for this module?

It means the module supports One Cable Technology (OCT) for Uninterruptible Power Supply (UPS) communication, allowing seamless interface with CU81xx battery units over a standard 24 V DC power line.

Does the CX2100-0024 have local diagnostics?

Yes, it features an integrated, illuminated FSTN display (2 lines x 16 characters) and three hardware status LEDs (PWR, I/O Run, I/O Err) for direct diagnostic monitoring.

What are the environmental limitations for this device?

The module operates in temperatures from -25 to +60 degC and resists relative humidity levels up to 95% non-condensing.

View all FAQs →

Quantity
Shipping & Returns

Global Express Shipping

  • Standard Delivery: 4–6 business days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our technical warranty.
Reviews
1 of 1
Only 10 item(s) left in stock
Quantity
View full details

Global Express Shipping

  • Standard Delivery: 4-6 Business Days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries, including rapid delivery to Saudi Arabia and UAE.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our professional technical warranty.

Orders are processed and delivered Monday-Friday (excluding public holidays).


For full eligibility, restocking fees, and international return details, please view our official Refund & Return Policy .

TECHNICAL SPECIFICATIONS

Country of origin
Germany

Technical knowledge

1746-A7 Chassis Replacement Checks: Slots, Power and Interconnects

An engineering checklist for replacing an Allen-Bradley 1746-A7: verify chassis series, backplane loading, slot plan, interconnect cables, mounting, grounding and receiving condition.

IC200MDL650 Replacement Checks: Logic Polarity, Filters, and Commons

A field replacement guide for GE Fanuc IC200MDL650 covering revision-dependent negative logic, four common groups, 24 VDC thresholds, input filtering, carrier checks and commissioning records.

IC697CPX935 Replacement Checks: Memory, Ports, and Rack Power

A field-focused IC697CPX935 replacement guide covering fast memory, firmware-dependent serial behavior, rack power, cooling, I/O architecture and backup records.

IC693DSM324 Replacement Checks: FSSB, Firmware and Follower Control

A field-focused IC693DSM324 replacement guide covering Series 90-30 host checks, FSSB servo-chain records, 5 V power budget, firmware limits, follower control and commissioning.

HIMA F3430 Replacement Checks: Contact Ratings and Safety Limits

A field-focused HIMA F3430 replacement guide covering relay contact ratings, DC load derating, fusing, F3330/F3331 differences, safety restrictions and commissioning records.

IC697PWR710 Replacement Checks: Load Budget and Dual-Rack Limits