BECKHOFF

BECKHOFF CX2100-0024 CX2000 Power Supply Module

SKU CX2100-0024

In stock
  • 12-month warranty
  • Free returns within 30 days
  • Manufacturer: BECKHOFF

  • Product No.: CX2100-0024

  • Country of origin:Germany

  • Product Type: Power Supply Modules

  • Payment: T/T, Western Union

  • Weight: 650g

  • Dimensions: 60 mm x 100 mm x 91 mm

  • Shipping port: Xiamen

  • Warranty: 12 months

Description

Engineered for modular integration within complex control systems, the BECKHOFF CX2100-0024 is a robust 240 W power supply module designed specifically to power CX20xx series Embedded PCs. This module serves as the central power interface, offering galvanic isolation and automatic recognition of the connected backplane bus system, whether using E-bus (EtherCAT) or K-bus (Bus Terminals).

The CX2100-0024 features Uninterruptible Power Supply (UPS) capabilities utilizing One Cable Technology (OCT) via a 24 V DC connection to the CU81xx series. Additionally, an illuminated front-panel FSTN display with 2 lines of 16 characters provides real-time diagnostic readouts and status information directly on the unit, optimizing onsite troubleshooting and system monitoring.

Features

  • Delivers up to 240 W of continuous power output to the CX20xx system.
  • Automatic bus recognition supports seamless switching between E-bus and K-bus technologies.
  • UPS OCT-capable interface enables streamlined communication and power backup integration with CU81xx devices.
  • Integrated 2-line x 16-character illuminated FSTN display for direct localized diagnostics.
  • Spring-loaded terminal connection system for reliable, vibration-resistant wiring.

Applications

  • Heavy industrial automation and process control systems using Beckhoff Embedded PCs.
  • Power plant and distribution control systems requiring integrated UPS functionality.
  • High-vibration manufacturing environments requiring secure spring-terminal connections.

Technical Specifications

Manufacturer Beckhoff Automation
Model / Part Number CX2100-0024
Input Voltage 24 V DC (-15 % / +20 %), electrically isolated
Max. Power Output 240 W
Max. Power Consumption 22 W
I/O Bus Support E-bus (EtherCAT) or K-bus (Bus Terminals), automatic recognition
Current Supply E-bus/K-bus 2 A
UPS Interface UPS OCT communication to CU81xx via 24 V DC cable
Connection Technology Spring-loaded technique (adapter terminal)
Display Type FSTN display, 2 lines x 16 characters, illuminated
Status Indicators 1 x PWR LED, 1 x I/O Run LED, 1 x I/O Err LED
Dimensions (W x H x D) 60 mm x 100 mm x 91 mm
Weight Approx. 650 g
Operating Temperature -25 to +60 degC
Storage Temperature -25 to +85 degC
Relative Humidity 95 %, non-condensing
Vibration/Shock Resistance Conforms to EN 60068-2-6 / EN 60068-2-27
EMC Immunity/Emission Conforms to EN 61000-6-2 / EN 61000-6-4
Protection Rating IP20

Installation Guidelines

The CX2100-0024 module is designed for standard DIN rail mounting as part of a modular CX20xx system block. Secure the module firmly onto the rail alongside the Embedded PC module. Ensure that wiring is completed using the spring-loaded adapter terminals to guarantee vibration-resistant contacts. Maintain appropriate clearance inside the control cabinet to facilitate passive ventilation and comply with the specified ambient operating temperature range of -25 to +60 degC.

Compliance and Certifications

  • CE
  • UL

FAQ

What is the primary function of the Beckhoff CX2100-0024?

The CX2100-0024 is a 240 W power supply module designed to power the CX20xx series of Embedded PCs while automatically managing and recognizing connection to E-bus (EtherCAT) or K-bus backplanes.

What does UPS OCT-capable mean for this module?

It means the module supports One Cable Technology (OCT) for Uninterruptible Power Supply (UPS) communication, allowing seamless interface with CU81xx battery units over a standard 24 V DC power line.

Does the CX2100-0024 have local diagnostics?

Yes, it features an integrated, illuminated FSTN display (2 lines x 16 characters) and three hardware status LEDs (PWR, I/O Run, I/O Err) for direct diagnostic monitoring.

What are the environmental limitations for this device?

The module operates in temperatures from -25 to +60 degC and resists relative humidity levels up to 95% non-condensing.

View all FAQs →

Quantity
Shipping & Returns

Global Express Shipping

  • Standard Delivery: 4–6 business days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our technical warranty.
Reviews
1 of 1
Only 10 item(s) left in stock
Quantity
View full details

Global Express Shipping

  • Standard Delivery: 4-6 Business Days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries, including rapid delivery to Saudi Arabia and UAE.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our professional technical warranty.

Orders are processed and delivered Monday-Friday (excluding public holidays).


For full eligibility, restocking fees, and international return details, please view our official Refund & Return Policy .

TECHNICAL SPECIFICATIONS

Country of origin
Germany

Technical knowledge

1756-OF4 Output Wrong? Check Mode, RTB, and Scaling First

A field-first diagnostic sequence for 1756-OF4 analog output problems: channel mode, removable terminal block, scaling, and controlled electrical checks.

1746-OA8 vs 1746-OA16: Output Count and Current Limits

A direct comparison of 1746-OA8 and 1746-OA16 output count, common grouping, backplane current and temperature-derated load limits.

Replacing a 1761-NET-DNI: Capture These Settings First

A field checklist for recording the 1761-NET-DNI hardware series, firmware, EDS file, DF1 settings, DeviceNet address and messaging configuration before replacement.

EL3062 vs EL3062-0030: The Input Range Changes

The EL3062 is a 0–10 V EtherCAT terminal. The EL3062-0030 is a 0–30 V variant. This checklist covers identification, scaling and commissioning.

Replacing a 1769-OW8: Checks Before Moving Relay Loads

A field checklist for replacing Allen-Bradley 1769-OW8 relay output modules without losing load-group, wiring, and commissioning details.

PLC I/O Modules: Wiring, Load, and Isolation Checks

A field checklist for matching PLC digital and analog I/O to sensors, loads, commons, isolation groups, filters, and replacement settings.