BECKHOFF

Beckhoff EL3443-0011 EtherCAT Terminal 3-channel Analog Input Power Measurement Terminal

SKU EL3443-0011

In stock
  • 12-month warranty
  • Free returns within 30 days
  • Manufacturer: BECKHOFF

  • Product No.: EL3443-0011

  • Country of origin:Germany

  • Product Type: EtherCAT Terminals

  • Payment: T/T, Western Union

  • Weight: 2000g

  • Dimensions: 120 mm x 80 mm x 25 mm

  • Shipping port: Xiamen

  • Warranty: 12 months

Designed for precise 3-phase AC/DC grid analysis, the Beckhoff EL3443-0011 functions as a high-performance power measurement terminal within the EtherCAT I/O system. This module enables direct measurement of current and voltage in supply networks, calculating key electrical parameters with high resolution and transmitting them directly to the controller via the high-speed EtherCAT bus.

Key Features

  • 3-channel voltage and 3-channel current measurement for comprehensive 3-phase power analysis.
  • High-resolution 24-bit analog-to-digital conversion for precise grid diagnostics.
  • Comprehensive parameter calculation including active, reactive, and apparent power, energy, cos phi, frequency, and harmonic analysis up to the 40th harmonic.
  • Mains monitoring capabilities with precise zero-voltage crossing detection.
  • Supports optional single-phase operation for versatile system integration.

Applications

  • Industrial power monitoring and energy management systems (EMS).
  • Grid quality analysis in manufacturing plants and substations.
  • Machine-level consumption tracking and predictive maintenance.
  • Integration with wind turbines, solar inverters, and generator sets.

Technical Specifications

Parameter Specification
Manufacturer Beckhoff
Model EL3443-0011
Number of Inputs 3 x current, 3 x voltage
Technology 3-phase power measurement
Measuring Voltage max. 480 V AC 3-phase (ULX-N: max. 277 V AC / 240 V DC)
Measuring Current 100 mA (AC/DC), via measuring transformers x A / 100 mA
Resolution 24 bit
Measuring Error 0.3% relative to full scale value (U/I), 0.6% calculated value
Update Interval One mains period (20 ms at 50 Hz)
Update Time Net-synchronous
Electrical Isolation 2500 V
Current Consumption E-bus typ. 120 mA
Operating Temperature 0 to +55 degC
Storage Temperature -25 to +85 degC
Relative Humidity 95 %, non-condensing
Vibration/Shock Resistance Conforms to EN 60068-2-6 / EN 60068-2-27
Material Polycarbonate
Dimensions (W x H x D) 12 mm x 100 mm x 68 mm
Shipping Weight 2.0 kg
Package Dimensions (Calculated) 120 mm x 80 mm x 25 mm

Connection Specifications

Conductor Type Cross-Section Range Stripping Length
Solid Conductor (s) 0.08 to 2.5 mm2 (AWG 28 to 14) 8 to 9 mm
Stranded Conductor (st) 0.08 to 2.5 mm2 (AWG 28 to 14) 8 to 9 mm
Flexible Conductor with Ferrule (f) 0.14 to 1.5 mm2 (AWG 26 to 16) 8 to 9 mm

Empirical Engineering Insights

Alternative Models & Compatibility

The EL3443-0011 is specifically calibrated for 100 mA current transformer (CT) secondary outputs. It must not be confused with the standard EL3443-0000 (which supports 1 A or 5 A CTs). Attempting to connect a 1 A/5 A CT directly to the EL3443-0011 will saturate the inputs and can permanently damage the internal shunt resistors.

Application Pitfalls & Engineering Notes

When measuring highly distorted grids, ensure that the harmonic analysis (up to the 40th harmonic) does not exceed the processing bandwidth of your TwinCAT cycle time. If cycle times are set too low, high-frequency CoE uploads of harmonic data can cause E-bus communication timeouts.

Commissioning & Wiring Tips

Always ensure that the current transformer polarity (K-L / P1-P2) matches the voltage phase allocation. Incorrect polarity or mismatched phases will result in negative active power readings and incorrect power factor (cos phi) calculations in the TwinCAT System Manager.

Installation Guidelines

CRITICAL WARNING: Risk of fatal electrical shock and equipment destruction. Always de-energize all voltage measurement lines and current transformer primary circuits before installing, removing, or wiring the terminal. Never open the secondary circuit of an active current transformer, as dangerously high open-circuit voltages will occur. Ensure the E-bus power contacts are completely isolated before mounting.
1
Mount the EL3443-0011 onto a standard 35 mm DIN rail (conforming to EN 60715) by sliding it until the lock mechanism engages securely.
2
Connect the voltage measurement lines to the designated terminals, ensuring correct phase assignment (L1, L2, L3, N).
3
Connect the 100 mA secondary outputs of your current transformers to the current inputs, observing correct polarity.
4
Power up the E-bus and configure the terminal parameters in TwinCAT System Manager, setting the correct transformer ratios.

FAQ

What is the maximum voltage rating for the EL3443-0011?

The terminal supports a maximum measuring voltage of 480 V AC 3-phase. For UL applications, the maximum phase-to-neutral voltage is 277 V AC and 240 V DC.

Can I use standard 1 A or 5 A current transformers with this module?

No, this model is designed specifically for 100 mA AC/DC secondary current inputs. Connecting 1 A or 5 A transformers directly will damage the internal shunt circuitry.

What parameters are calculated by the internal processor?

It calculates active, reactive, and apparent power/energy, power factor (cos phi), frequency, total harmonic distortion (THD), and individual harmonics up to the 40th harmonic.

View all FAQs →

Quantity
Shipping & Returns

Global Express Shipping

  • Standard Delivery: 4–6 business days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our technical warranty.
Reviews
1 of 1
Only 10 item(s) left in stock
Quantity
View full details

Global Express Shipping

  • Standard Delivery: 4-6 Business Days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries, including rapid delivery to Saudi Arabia and UAE.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our professional technical warranty.

Orders are processed and delivered Monday-Friday (excluding public holidays).


For full eligibility, restocking fees, and international return details, please view our official Refund & Return Policy .

TECHNICAL SPECIFICATIONS

Country of origin
Germany

Technical knowledge

Commissioning AS-Interface Networks Without Guesswork

A practical AS-Interface commissioning method covering topology, power and voltage-drop checks, addressing, PLC mapping, fault tests and maintenance records for reliable actuator-sensor networks.

Selecting Line Reactors and Output Filters for VFDs

Learn how line reactors, harmonic filters, output reactors, dV/dt filters, and sine filters address different VFD power-quality and motor-cable problems—and how to select them safely.

Light-On and Dark-On Photoelectric Sensor Logic

Learn how light-on and dark-on photoelectric sensor modes interact with through-beam, retroreflective, and diffuse sensing, PNP/NPN wiring, PLC logic, commissioning, and fault detection.

Designing H-Bridge Motor Drives Without Shoot-Through

A practical guide to H-bridge motor drives covering switching states, dead time, inductive current paths, PWM choices, protection, PCB layout, PLC interfacing, and staged commissioning tests.

Designing Mitsubishi FX PLC Sequences with STL and RET

Learn how Mitsubishi FX PLC STL and RET instructions structure conveyor and pneumatic sequences, with practical state design, transition logic, timeouts, diagnostics, and safe restart boundaries.

Selecting and Troubleshooting DIN Valve Connectors

A practical guide to selecting, wiring and diagnosing DIN-style valve connectors, including form identification, coil voltage, suppression, polarity, sealing, release-time effects and commissioning...