BECKHOFF

BECKHOFF ERI2008-0001 IO-Link Box

SKU ERI2008-0001

In stock
  • 12-month warranty
  • Free returns within 30 days
  • Manufacturer: BECKHOFF

  • Product No.: ERI2008-0001

  • Country of origin:Germany

  • Product Type: IO-Link Modules

  • Payment: T/T, Western Union

  • Weight: 500g

  • Dimensions: 30 mm x 126 mm x 26.5 mm

  • Shipping port: Xiamen

  • Warranty: 12 months

Description

The BECKHOFF ERI2008-0001 is an IO-Link box designed for distributed industrial automation environments. Engineered with a robust zinc die-cast housing, this device provides decentralized signal connection directly in the machine environment without requiring a control cabinet. It acts as an IO-Link device supporting specification version V1.1, Class B, facilitating reliable communication and power distribution for connected field devices.

Equipped with eight digital outputs, the module handles ohmic, inductive, and lamp loads efficiently. It integrates standard M8 and M12 connection technology to interface with field sensors and actuators while maintaining high resistance to environmental factors through its IP65, IP66, and IP67 protection ratings.

Features

  • IO-Link communication interface supporting data transfer rates up to 230.4 kbaud (COM 3)
  • IO-Link specification version V1.1, Class B functionality
  • Eight digital outputs with M8 screw-type connections
  • Individually short-circuit proof outputs with a maximum current of 0.5 A per channel
  • Durable zinc die-cast housing suited for harsh industrial conditions
  • IP65, IP66, and IP67 protection ratings for unshielded machine mounting

Applications

  • Decentralized machine control and factory automation
  • Actuator connection in harsh industrial environments
  • Machine installations requiring cabinet-free I/O distribution
  • Modular production lines utilizing IO-Link communication architecture

Technical Specifications

General

Parameter Specification
Manufacturer BECKHOFF
Exact Model ERI2008-0001
Product Type IO-Link Box
Housing Material Zinc die-cast
Dimensions (W x H x D) 30 mm x 126 mm x 26.5 mm
Net Weight 265 g
Country of Origin Germany

Communication

Parameter Specification
Communication Type IO-Link
Specification Version IO-Link V1.1, Class B
Data Transfer Rates 230.4 kbaud (COM 3)

Signal and I/O

Parameter Specification
Number of Outputs 8
Load Type Ohmic, inductive, lamp load
Nominal Output Voltage 24 V DC (-15 % / +20 %)
Max. Output Current 0.5 A per channel, from P24, individually short-circuit proof
Short-Circuit Current Typ. 1.5 A

Electrical

Parameter Specification
Current Consumption Typ. 100 mA from L+
Auxiliary Power Current Typ. 20 mA + load
Electrical Isolation L+ / P24: Yes

Connections

Parameter Specification
Interfaces 1 x M12 plug, A-coded
Output Connections 8 x M8, screw type

Environmental and Mechanical

Parameter Specification
Operating Temperature Range -25 to +60 degC
Storage Temperature Range -40 to +85 degC
Protection Rating IP65 / IP66 / IP67 (conforms to EN 60529)
Installation Position Variable
Vibration / Shock Resistance Conforms to EN 60068-2-6 / EN 60068-2-27
EMC Immunity / Emission Conforms to EN 61000-6-2 / EN 61000-6-4
Mounting 2 fixing holes 3.5 mm diameter for M3 screws

Approvals

Parameter Specification
Approvals and Markings CE, UL

Connections / Interfaces

Interface Function
1 x M12 plug, A-coded IO-Link communication and supply connection
8 x M8 sockets, screw type Digital output channels

Installation Guidelines

  1. Ensure the system is completely de-energized before beginning any mechanical or electrical installation work.
  2. Inspect the ERI2008-0001 housing, seals, and connection pins for any signs of transport damage.
  3. Mount the module securely onto a flat machine surface using two 3.5 mm fixing holes designated for M3 screws.
  4. Verify that field-side power supplies match the nominal 24 V DC requirements and are correctly fused.
  5. Connect the IO-Link master line to the M12 A-coded interface and attach actuators to the M8 output ports.
  6. Check all connections and cable shields for secure seating before restoring power to the system.

FAQ

What is the BECKHOFF ERI2008-0001 and how does it function?

The BECKHOFF ERI2008-0001 is a decentralized IO-Link box designed to provide cabinet-free signal connection directly within harsh machine environments. Engineered with a durable zinc die-cast housing, this module supports IO-Link specification V1.1, Class B for reliable communication and power distribution. It features eight digital outputs that efficiently handle ohmic, inductive, and lamp loads.

What communication protocols and data rates are supported?

The BECKHOFF ERI2008-0001 utilizes an IO-Link communication interface supporting data transfer rates up to 230.4 kbaud via COM 3. It interfaces with master systems through a single M12 plug with A-coding for combined communication and supply connection. The module operates strictly in accordance with IO-Link V1.1 Class B standards.

What are the output specifications and load capabilities?

The BECKHOFF ERI2008-0001 is equipped with eight digital outputs utilizing standard M8 screw-type connections. Each channel provides a maximum nominal output current of 0.5 A driven from the P24 supply and is individually short-circuit proof. The outputs are fully compatible with ohmic, inductive, and lamp load types operating at a nominal voltage of 24 V DC.

What environmental protection ratings does this IO-Link box feature?

The BECKHOFF ERI2008-0001 offers high resistance to environmental factors with IP65, IP66, and IP67 protection ratings. This robust sealing makes it ideally suited for unshielded machine mounting in wet or dusty industrial areas. It operates reliably within an ambient temperature range of -25 to +60 degrees Celsius.

How is the module physically installed and powered?

The BECKHOFF ERI2008-0001 mounts securely onto flat machine surfaces using two 3.5 mm fixing holes designed for M3 screws. It requires a nominal 24 V DC field-side power supply and typically consumes 100 mA from L+ alongside auxiliary power for the load. Installers must ensure the system is completely de-energized before mounting the module or attaching cables to the M8 and M12 ports.

View all FAQs →

Quantity
Shipping & Returns

Global Express Shipping

  • Standard Delivery: 4–6 business days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our technical warranty.
Reviews
1 of 1
Only 10 item(s) left in stock
Quantity
View full details

Global Express Shipping

  • Standard Delivery: 4-6 Business Days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries, including rapid delivery to Saudi Arabia and UAE.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our professional technical warranty.

Orders are processed and delivered Monday-Friday (excluding public holidays).


For full eligibility, restocking fees, and international return details, please view our official Refund & Return Policy .

TECHNICAL SPECIFICATIONS

Country of origin
Germany

Technical knowledge

Diagnosing DeltaV SE5009 Power Problems Before Replacement

A field checklist for separating 24 VDC input, carrier bus, output derating and alarm-contact faults before replacing an Emerson SE5009.

Commissioning Quantum Inputs with the 140XSM00200 Simulator

A controlled commissioning method for using the 140XSM00200 simulator to verify Modicon Quantum input mapping and interlocks before reconnecting field wiring.

Commissioning PLX32-EIP-MBTCP: Subnets, Registers, and RPI

A commissioning checklist for the ProSoft PLX32-EIP-MBTCP covering subnet separation, register contracts, EtherNet/IP timing, failure tests and replacement records.

Diagnosing IC693MDL916 Relay Outputs Before Module Replacement

A field checklist for IC693MDL916 relay commands, terminal blocks, load current, switching rate and contact-side measurements.

Troubleshooting Beckhoff KL1512 Counter Inputs and Mapping

A field checklist for KL1512 signal thresholds, counter direction, process data and the KL1512-to-KS1512 wiring difference.

Troubleshooting Beckhoff EPP2008-0001 Output Faults

A field checklist for EPP2008-0001 current limits, supply voltage, channel LEDs, connector coding and load-related output faults.