BECKHOFF

Beckhoff IP2000-B200 Fieldbus Box 8-Channel Digital Output Module

SKU IP2000-B200

In stock
  • 12-month warranty
  • Free returns within 30 days
  • Manufacturer: BECKHOFF

  • Product No.: IP2000-B200

  • Country of origin:Germany

  • Product Type: Fieldbus Boxes

  • Payment: T/T, Western Union

  • Weight: 2000g

  • Shipping port: Xiamen

  • Warranty: 12 months

Description

Engineered for decentralized automation tasks, the IP2000-B200 serves as a robust Fieldbus Box interface within the Beckhoff Lightbus system. This module features 8 digital outputs, handling actuator control directly in the field without requiring an additional protective control cabinet. By routing signals via the highly deterministic Lightbus fiber-optic ring structure, the unit ensures high-speed, noise-immune data communication even in environments with severe electromagnetic interference (EMI).

The IP2000-B200 digital output module connects binary control signals from the automation device to the actuators at the process level. This localized connection significantly reduces cabling costs, simplifies troubleshooting, and optimizes system diagnostic capabilities down to the individual channel level.

Features

  • Equipped with 8 digital output channels for direct actuator control.
  • Utilizes the high-speed Beckhoff Lightbus fiber-optic communication system.
  • Standard Ø8 mm optical fiber connectors for secure and reliable data transmission.
  • Short-circuit proof outputs with integrated protective wiring.
  • Local status LED indicators for quick diagnostic verification of each channel.
  • Compact, machine-mountable design to save space and reduce wiring runs.

Applications

  • Machine building and manufacturing systems
  • Automated assembly and packaging lines
  • Material handling and high-speed sorting conveyors
  • Environments requiring high immunity to electromagnetic interference

Technical Specifications

Manufacturer Beckhoff
Model/Part Number IP2000-B200
Product Type Fieldbus Box (Digital Output Module)
Fieldbus Protocol Lightbus
Number of Outputs 8 digital outputs
Nominal Voltage 24 V DC
Output Current 0.5 A per channel
Connection Type Ø8 mm optical fiber connectors (Lightbus)
Shipping Weight 2 kg

Connections and Interfaces

Interface Type Function Description
Lightbus IN (Ø8 mm) Fiber-optic ring input for network communication
Lightbus OUT (Ø8 mm) Fiber-optic ring output to downstream modules
Channels 1 - 8 Digital output signal connections for field actuators
Power Supply Connection 24 V DC control voltage input

Installation Guidelines

  • Mount the module directly onto the machine frame or flat surface using the integrated mounting holes.
  • Ensure the Lightbus fiber-optic cables are routed with care, adhering to the minimum bending radius specifications to avoid signal attenuation or physical damage.
  • Ensure all unused connection ports are sealed to maintain environmental integrity.
  • Disconnect the power supply before connecting or disconnecting the fiber-optic or signal cables.

Compliance and Certifications

  • CE

FAQ

What is the primary communication interface for the IP2000-B200?

The IP2000-B200 utilizes the Beckhoff Lightbus fiber-optic interface (Ø8 mm connections) for high-speed, noise-immune fieldbus communication.

What is the load capacity of each digital output channel?

Each of the 8 digital output channels supports a nominal load current of up to 0.5 A at 24 V DC.

Does the IP2000-B200 require a separate control cabinet for installation?

No, the Fieldbus Box series is designed for direct machine mounting, allowing decentralized installation outside of traditional electrical control cabinets.

View all FAQs →

Quantity
Shipping & Returns

Global Express Shipping

  • Standard Delivery: 4–6 business days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our technical warranty.
Reviews
1 of 1
Only 10 item(s) left in stock
Quantity
View full details

Global Express Shipping

  • Standard Delivery: 4-6 Business Days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries, including rapid delivery to Saudi Arabia and UAE.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our professional technical warranty.

Orders are processed and delivered Monday-Friday (excluding public holidays).


For full eligibility, restocking fees, and international return details, please view our official Refund & Return Policy .

TECHNICAL SPECIFICATIONS

Country of origin
Germany

Technical knowledge

Allen-Bradley 1771-IG: TTL Logic and 5 V Wiring Checks

Check 1771-IG TTL HIGH/LOW logic thresholds, field supply ripple and 1771-WC wiring before replacing an input module.

AKS 33 vs AKS 3000: Checks Before Replacing a Pressure Transmitter

A field checklist for distinguishing Danfoss 060G2105, 060G1323 and 060G2109 by pressure range, fitting, loop signal and controller scaling.

Diagnosing DeltaV SE5009 Power Problems Before Replacement

A field checklist for separating 24 VDC input, carrier bus, output derating and alarm-contact faults before replacing an Emerson SE5009.

Commissioning Quantum Inputs with the 140XSM00200 Simulator

A controlled commissioning method for using the 140XSM00200 simulator to verify Modicon Quantum input mapping and interlocks before reconnecting field wiring.

Commissioning PLX32-EIP-MBTCP: Subnets, Registers, and RPI

A commissioning checklist for the ProSoft PLX32-EIP-MBTCP covering subnet separation, register contracts, EtherNet/IP timing, failure tests and replacement records.

Diagnosing IC693MDL916 Relay Outputs Before Module Replacement

A field checklist for IC693MDL916 relay commands, terminal blocks, load current, switching rate and contact-side measurements.