The BECKHOFF IP2002-B318 is an 8-channel digital output Fieldbus Box designed for decentralized industrial automation architectures. Operating on the PROFIBUS DP communication protocol, this device integrates directly into machine-level topologies without requiring a control cabinet, utilizing an IP65, IP66, and IP67 protection class housing suitable for harsh environments. The unit features eight digital outputs capable of switching up to 0.5 A per channel with individual short-circuit protection.

Equipped with an integrated T-connector for the PROFIBUS interface and M12 connection technology for signal wiring, the IP2002-B318 simplifies network integration and maintenance. It supports automatic baud rate detection up to 12 Mbaud and configuration via software tools or controller parameters. Control and load voltage supplies are routed through M8 power connections, providing feed and downstream distribution capabilities in an XXL polyamide housing format.

Features

  • 8-channel digital output module in an XXL Fieldbus Box format
  • Integrated PROFIBUS DP interface with automatic data transfer rate detection up to 12 Mbaud
  • Integrated T-connector with M12 socket and plug (B-coded) for bus connection
  • Nominal output voltage of 24 V DC with a maximum output current of 0.5 A per channel
  • Individually short-circuit proof outputs supporting ohmic, inductive, and lamp loads
  • M8 power supply connections for feed and downstream power distribution
  • High environmental protection rating of IP65, IP66, and IP67 for machine-level mounting

Applications

  • Decentralized digital actuator control in machine building and plant engineering
  • PROFIBUS-based industrial automation networks operating outside control cabinets
  • Switching of ohmic, inductive, and lamp loads in distributed production lines

Technical Specifications

General

Parameter Specification
Manufacturer BECKHOFF
Exact Model IP2002-B318
Product Type Fieldbus Box
Housing Type XXL housing
Material PA6 (polyamide)
Dimensions (W x H x D) 30 mm x 210 mm x 26.5 mm
Installation 2 fixing holes 3.5 mm diameter for M3
Country of Origin Germany

Digital Outputs

Parameter Specification
Number of Outputs 8
Output Connections M12, screw type
Load Type Ohmic, inductive, lamp load
Nominal Output Voltage 24 V DC (-15 %/+20 %)
Max. Output Current 0.5 A per channel, individually short-circuit proof
Short-Circuit Current Typ. 1.5 A
Bit Width in Process Image 8 outputs

PROFIBUS Communication

Parameter Specification
Bus System PROFIBUS DP
Data Transfer Rates Automatic detection up to 12 Mbaud
Bus Interface 1 x M12 socket, 5-pin, 1 x M12 plug, 5-pin (tee-connector integrated), B-coded
Configuration Via KS2000 or controller, DP-V1 extensions supported

Power Supply and Electrical Data

Parameter Specification
Control Voltage Supply 24 V DC (-15 %/+20 %)
Power Supply Connection Feed: 1 x M8 male socket, 4-pin; Downstream connection: 1 x M8 female socket, 4-pin
Box Supply Current 85 mA + current consumption of sensors, max. 0.5 A
Electrical Isolation Control voltage/fieldbus: no; Control voltage/outputs: according to I/O type

Environmental and Mechanical Ratings

Parameter Specification
Operating Temperature Range 0 to +55 Celsius
Storage Temperature Range -25 to +85 Celsius
Vibration/Shock Resistance Conforms to EN 60068-2-6 / EN 60068-2-27
EMC Immunity/Emission Conforms to EN 61000-6-2 / EN 61000-6-4
Protection Class IP65, IP66, IP67 (conforms to EN 60529)
Approvals/Markings CE, UL

Installation Guidelines

  1. Ensure the system is completely de-energized before mounting or wiring the Fieldbus Box.
  2. Mount the XXL housing securely to a flat surface using two M3 screws through the designated 3.5 mm fixing holes.
  3. Connect the PROFIBUS network cable to the integrated M12 T-connector interface, ensuring proper B-coding alignment.
  4. Attach the 24 V DC control and load voltage supplies to the M8 feed socket, maintaining correct polarity and voltage tolerances.
  5. Connect actuators to the M12 output channels, verifying that load currents do not exceed 0.5 A per channel.
  6. Verify all cable connections, shield terminations, and bus addresses before restoring power to the system.

FAQ

What is the BECKHOFF IP2002-B318 and where is it used?

The BECKHOFF IP2002-B318 is an 8-channel digital output Fieldbus Box engineered for decentralized industrial automation architectures. It operates directly at the machine level without requiring a control cabinet. This device is ideal for distributed production lines and harsh shop-floor environments.

What communication protocol and baud rates does this Fieldbus Box support?

The BECKHOFF IP2002-B318 utilizes the PROFIBUS DP communication protocol for reliable industrial network integration. It features an integrated M12 T-connector interface with automatic baud rate detection up to 12 Mbaud. Network configuration can be easily handled via software tools like KS2000 or directly through controller parameters.

What are the electrical ratings for the digital outputs?

The BECKHOFF IP2002-B318 provides eight digital outputs operating at a nominal voltage of 24 V DC. Each channel is capable of switching up to 0.5 A with individual short-circuit protection. The outputs successfully support ohmic, inductive, and lamp loads.

What environmental protection ratings does the housing offer?

The BECKHOFF IP2002-B318 features a robust XXL polyamide housing rated for IP65, IP66, and IP67 protection classes. This high level of environmental resistance allows direct mounting onto machinery exposed to dust, moisture, and aggressive washdown conditions. It conforms strictly to EN 60529 standards for industrial reliability.

How are power and signal connections established on the unit?

The BECKHOFF IP2002-B318 utilizes secure M12 connection technology for all signal wiring and bus communication. Control and load voltage supplies are routed via M8 power connections, which allow both feed and downstream distribution capabilities. Installation is completed using two M3 fixing holes on the durable PA6 housing.

View all FAQs →

Quantity
Shipping & Returns

Global Express Shipping

  • Standard Delivery: 4–6 business days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our technical warranty.
Reviews
1 of 1
Only 10 item(s) left in stock
Quantity
View full details

Global Express Shipping

  • Standard Delivery: 4-6 Business Days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries, including rapid delivery to Saudi Arabia and UAE.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our professional technical warranty.

Orders are processed and delivered Monday-Friday (excluding public holidays).


For full eligibility, restocking fees, and international return details, please view our official Refund & Return Policy .

TECHNICAL SPECIFICATIONS

Country of origin
Germany

Technical knowledge

ABB PM891K01 Replacement: Check Redundancy Before Ordering

ABB PM891K01 article 3BSE053241R1 is the non-redundant AC 800M processor kit. Use this field checklist before replacement.

ABB TP853 Replacement Checks for CI853/CI855/CI857/CI861

Replacement checks for ABB TP853 3BSE018126R1: identify the installed CI853, CI855, CI857, or CI861 interface, record wiring, and verify communication after installation.

5069-L330ERMS2 Startup Checks: RTBs, I/O, and Motion Limits

Engineering checks for the Allen-Bradley 5069-L330ERMS2: controller capacity, separate RTB kits, local I/O limits, network-node limits, and motion-axis count.

Replacing ABB DSQC 351: Controller and Network Checks

Checks to record before replacing ABB 3HNE 00006-1 DSQC 351: controller generation, X3/X5/X20/X21 wiring, DeviceNet settings, INTERBUS mapping, and LED states.

IC693CPU360 vs IC693CPU364: Ethernet and Power Budget

Compare the IC693CPU360 and IC693CPU364 by Ethernet interface, +5 VDC load, memory, rack limits, and replacement checks.

1756-OF4 Output Wrong? Check Mode, RTB, and Scaling First

A field-first diagnostic sequence for 1756-OF4 analog output problems: channel mode, removable terminal block, scaling, and controlled electrical checks.