Description
The BECKHOFF IP2310-B200 is a rugged fieldbus interface module designed for distributed automation architectures. Operating within the fiber-optic Lightbus system, this unit combines digital input and digital output functions in a single compact enclosure, making it highly effective for localized signal acquisition and actuator control directly on industrial machinery.
With its high degree of protection, the BECKHOFF IP2310-B200 operates reliably outside of traditional electrical control cabinets. The fiber-optic interface provides outstanding electrical isolation and complete immunity against electromagnetic interference, ensuring stable transmission of critical I/O data over extended distances.
Features
- Consolidates 4 digital inputs and 4 digital outputs in one device to reduce wiring runs.
- Features integrated fiber-optic Lightbus communication for high-speed, noise-free network integration.
- Utilizes Ø8 mm snap-type circular connection technology for fast and secure sensor and actuator wiring.
- Encased in an IP67-rated housing to protect against moisture, dust, and mechanical stress.
- Designed for direct, decentralized machine mounting in demanding production environments.
Applications
- Decentralized machine control and signal processing.
- Applications requiring high electromagnetic noise immunity via optical communication networks.
- Direct machine-level mounting where control cabinet space is constrained.
Technical Specifications
General
| Parameter |
Specification |
| Manufacturer |
BECKHOFF |
| Model Number |
IP2310-B200 |
| Product Type |
Fieldbus Box (Combi Module) |
| Fieldbus Interface |
Lightbus (optical fiber) |
Signal and Electrical
| Parameter |
Specification |
| Digital Inputs |
4 channels (24 V DC) |
| Digital Outputs |
4 channels (24 V DC) |
| Max. Output Current |
0.5 A per channel |
| Connection Type |
Ø8 mm snap-type circular connectors |
Mechanical and Environmental
| Parameter |
Specification |
| Protection Class |
IP67 |
Installation Guidelines
- Ensure that all system power sources are completely de-energized before mounting.
- Securely mount the module on a flat machine surface using the integrated mounting points.
- Connect the fiber-optic Lightbus cables, observing the correct direction of optical transmission and minimum bend radius.
- Connect the 24 V DC field power supply, verifying correct polarity before activation.
- Attach the digital sensors and actuators to the corresponding Ø8 mm snap-type ports.
- Apply power and monitor the status indicators to verify normal startup and network communication.
Replacement Recommendations
When replacing a unit, verify and document all optical cable routings to preserve correct signal loops. Ensure the field supply voltage is disconnected before handling any connection points. After mounting the replacement device, inspect the physical fiber connections and verify the communication LEDs to confirm proper re-integration into the Lightbus network.