BECKHOFF

BECKHOFF IP2310-B518 Fieldbus Box

SKU IP2310-B518

In stock
  • 12-month warranty
  • Free returns within 30 days
  • Manufacturer: BECKHOFF
  • Product No.: IP2310-B518
  • Origin Germany
  • Product Type: Fieldbus Boxes
  • Payment: T/T, Western Union
  • Weight: 2.0 kg
  • Shipping port: Xiamen
  • Warranty: 12 months

Tags

Quantity

Product Description

Description

The BECKHOFF IP2310-B518 is a high-performance Fieldbus Box designed for decentralized automation architectures. By eliminating the need for a protective control cabinet, this IP67-rated module allows direct machine-level mounting, reducing cabling overhead and streamlining system deployment. The device integrates both digital input and digital output channels into a compact, dust-tight, and water-resistant housing.

This module features the B518 CANopen fieldbus interface, which includes an integrated T-connector. This integrated design simplifies network topology by enabling direct daisy-chain cabling from box to box without requiring external T-pieces. The BECKHOFF IP2310-B518 is engineered to interface reliably with controllers over a CANopen network, handling real-time status signals and actuation commands in harsh industrial settings.

For signal connections, the module provides standardized M8 (diameter 8 mm) circular connectors. These screw-type connectors ensure a vibration-proof mechanical connection, maintaining signal integrity and protection ratings under continuous physical stress. Each channel is equipped with status LEDs for localized diagnostic verification during operation and commissioning.

Features

  • Integrated CANopen fieldbus communication interface with an onboard T-connector for simplified network daisy-chaining.
  • Four digital inputs (24 V DC) with fast signal acquisition for standard sensors and switches.
  • Four digital outputs (24 V DC) rated at 0.5 A per channel for driving actuators, solenoids, and indicators.
  • Compact IP67-rated housing for decentralized installation directly on machines or transport systems.
  • Standardized M8 (diameter 8 mm) circular screw-connection sockets for highly secure, moisture-resistant I/O connections.
  • Clear diagnostic and status LEDs for both bus communication status and individual I/O channels.

Applications

  • Decentralized control architectures requiring high-protection I/O deployment directly in the field.
  • Material handling systems, conveyor lines, and sorting systems utilizing CANopen networks.
  • Machine tool manufacturing, assembly machines, and packaging equipment with space-constrained cabinet layouts.
  • Robotic end-of-arm tooling and end-effector signal distribution.

Technical Specifications

Parameter Specification
Manufacturer BECKHOFF
Model Number IP2310-B518
Product Type Fieldbus Box
Fieldbus Protocol CANopen
Fieldbus Connection Integrated T-connector (B518)
Number of Digital Inputs 4
Number of Digital Outputs 4
Nominal Voltage 24 V DC
Output Current Max. 0.5 A per channel
I/O Connection Type M8 (diameter 8 mm) circular screw socket
Input Filter Time 0.2 ms
Ingress Protection Rating IP67
Operating Temperature 0 to +55 degC
Storage Temperature -25 to +85 degC

Connections / Interfaces

Interface or Terminal Function
CANopen Interface Integrated T-connector for fieldbus communication and daisy-chaining
I/O Channels (Channels 1 - 8) M8 screw sockets for 4 digital inputs and 4 digital outputs
Power Supply Connection M8 plug/socket for control voltage and load voltage distribution

Installation Guidelines

  1. Verify that the BECKHOFF IP2310-B518 is the correct model for your system's fieldbus requirements and electrical configurations before starting installation.
  2. Ensure all electrical power sources (control and load supply) are fully de-energized before mounting or servicing.
  3. Securely mount the Fieldbus Box to a flat, vibration-free surface using the integrated mounting holes to ensure proper mechanical stability and automatic grounding where applicable.
  4. Connect the CANopen network cables to the integrated T-connector interface, verifying correct pin assignments and termination at the network ends.
  5. Attach sensor and actuator cables to the standard M8 circular sockets, ensuring they are screwed down securely to maintain the IP67 moisture and dust seal.
  6. Check polarity and voltage levels of the 24 V DC supply before powering on the system.
  7. Perform configuration and diagnostics using your CANopen master engineering software.
Shipping & Returns

Global Express Shipping

  • Standard Delivery: 4–6 business days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our technical warranty.
FAQ
What is the primary function of the BECKHOFF IP2310-B518?
The BECKHOFF IP2310-B518 is a decentralized Fieldbus Box designed to interface 4 digital inputs and 4 digital outputs directly at the machine level over a CANopen network, eliminating the need for a control cabinet.
How does the integrated T-connector on the IP2310-B518 benefit my system design?
The BECKHOFF IP2310-B518 features an integrated T-connector in its CANopen interface (B518), which allows you to easily daisy-chain the fieldbus line from one module to another without requiring separate, external T-pieces or complex splitters.
What connector style is used for standard sensor and actuator wiring on this module?
The BECKHOFF IP2310-B518 uses standard M8 (diameter 8 mm) circular screw-type connectors for all I/O channels, providing a vibration-resistant and highly secure physical connection.
What is the environmental protection level of the IP2310-B518?
The BECKHOFF IP2310-B518 has an IP67 protection rating, making it completely dust-tight and resistant to water ingress when all M8 connections are properly mated and tightened.
Are there onboard diagnostic indicators on the IP2310-B518?
Yes, the BECKHOFF IP2310-B518 is equipped with localized status LEDs that indicate the status of the CANopen bus connection, power supply health, and the logical states of each individual digital input and output channel.
Reviews

IP2310-B518

Stock & lead time on request

Call
1 of 1

BECKHOFF IP2310-B518 Fieldbus Box

Only 10 item(s) left in stock
  • Manufacturer: BECKHOFF

  • Product No.: IP2310-B518

  • Country of origin:Germany

  • Product Type: Fieldbus Boxes

  • Payment: T/T, Western Union

  • Weight: 2000g

  • Shipping port: Xiamen

  • Warranty: 12 months

Quantity
View full details

Product Description

Description

The BECKHOFF IP2310-B518 is a high-performance Fieldbus Box designed for decentralized automation architectures. By eliminating the need for a protective control cabinet, this IP67-rated module allows direct machine-level mounting, reducing cabling overhead and streamlining system deployment. The device integrates both digital input and digital output channels into a compact, dust-tight, and water-resistant housing.

This module features the B518 CANopen fieldbus interface, which includes an integrated T-connector. This integrated design simplifies network topology by enabling direct daisy-chain cabling from box to box without requiring external T-pieces. The BECKHOFF IP2310-B518 is engineered to interface reliably with controllers over a CANopen network, handling real-time status signals and actuation commands in harsh industrial settings.

For signal connections, the module provides standardized M8 (diameter 8 mm) circular connectors. These screw-type connectors ensure a vibration-proof mechanical connection, maintaining signal integrity and protection ratings under continuous physical stress. Each channel is equipped with status LEDs for localized diagnostic verification during operation and commissioning.

Features

  • Integrated CANopen fieldbus communication interface with an onboard T-connector for simplified network daisy-chaining.
  • Four digital inputs (24 V DC) with fast signal acquisition for standard sensors and switches.
  • Four digital outputs (24 V DC) rated at 0.5 A per channel for driving actuators, solenoids, and indicators.
  • Compact IP67-rated housing for decentralized installation directly on machines or transport systems.
  • Standardized M8 (diameter 8 mm) circular screw-connection sockets for highly secure, moisture-resistant I/O connections.
  • Clear diagnostic and status LEDs for both bus communication status and individual I/O channels.

Applications

  • Decentralized control architectures requiring high-protection I/O deployment directly in the field.
  • Material handling systems, conveyor lines, and sorting systems utilizing CANopen networks.
  • Machine tool manufacturing, assembly machines, and packaging equipment with space-constrained cabinet layouts.
  • Robotic end-of-arm tooling and end-effector signal distribution.

Technical Specifications

Parameter Specification
Manufacturer BECKHOFF
Model Number IP2310-B518
Product Type Fieldbus Box
Fieldbus Protocol CANopen
Fieldbus Connection Integrated T-connector (B518)
Number of Digital Inputs 4
Number of Digital Outputs 4
Nominal Voltage 24 V DC
Output Current Max. 0.5 A per channel
I/O Connection Type M8 (diameter 8 mm) circular screw socket
Input Filter Time 0.2 ms
Ingress Protection Rating IP67
Operating Temperature 0 to +55 degC
Storage Temperature -25 to +85 degC

Connections / Interfaces

Interface or Terminal Function
CANopen Interface Integrated T-connector for fieldbus communication and daisy-chaining
I/O Channels (Channels 1 - 8) M8 screw sockets for 4 digital inputs and 4 digital outputs
Power Supply Connection M8 plug/socket for control voltage and load voltage distribution

Installation Guidelines

  1. Verify that the BECKHOFF IP2310-B518 is the correct model for your system's fieldbus requirements and electrical configurations before starting installation.
  2. Ensure all electrical power sources (control and load supply) are fully de-energized before mounting or servicing.
  3. Securely mount the Fieldbus Box to a flat, vibration-free surface using the integrated mounting holes to ensure proper mechanical stability and automatic grounding where applicable.
  4. Connect the CANopen network cables to the integrated T-connector interface, verifying correct pin assignments and termination at the network ends.
  5. Attach sensor and actuator cables to the standard M8 circular sockets, ensuring they are screwed down securely to maintain the IP67 moisture and dust seal.
  6. Check polarity and voltage levels of the 24 V DC supply before powering on the system.
  7. Perform configuration and diagnostics using your CANopen master engineering software.
Loading product navigation…

What is the primary function of the BECKHOFF IP2310-B518?

The BECKHOFF IP2310-B518 is a decentralized Fieldbus Box designed to interface 4 digital inputs and 4 digital outputs directly at the machine level over a CANopen network, eliminating the need for a control cabinet.

How does the integrated T-connector on the IP2310-B518 benefit my system design?

The BECKHOFF IP2310-B518 features an integrated T-connector in its CANopen interface (B518), which allows you to easily daisy-chain the fieldbus line from one module to another without requiring separate, external T-pieces or complex splitters.

What connector style is used for standard sensor and actuator wiring on this module?

The BECKHOFF IP2310-B518 uses standard M8 (diameter 8 mm) circular screw-type connectors for all I/O channels, providing a vibration-resistant and highly secure physical connection.

What is the environmental protection level of the IP2310-B518?

The BECKHOFF IP2310-B518 has an IP67 protection rating, making it completely dust-tight and resistant to water ingress when all M8 connections are properly mated and tightened.

Are there onboard diagnostic indicators on the IP2310-B518?

Yes, the BECKHOFF IP2310-B518 is equipped with localized status LEDs that indicate the status of the CANopen bus connection, power supply health, and the logical states of each individual digital input and output channel.

Global Express Shipping

  • Standard Delivery: 4-6 Business Days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries, including rapid delivery to Saudi Arabia and UAE.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our professional technical warranty.

Orders are processed and delivered Monday-Friday (excluding public holidays).


For full eligibility, restocking fees, and international return details, please view our official Refund & Return Policy .

TECHNICAL SPECIFICATIONS

Country of origin
Germany

Technical knowledge

1756-L73 Firmware Upgrade Guide: v19 vs v21/v31 Decision

Replacing a 1756-L73 does not automatically mean upgrading its firmware. This guide compares v19.013, v21.011 and v31.011, focusing on project compatibility, HMI communications, legacy networks and...

Implementing 3-Switch XOR Ladder Logic with Internal Bit

Implement a 3-SPST switch XOR light circuit in LogixPro or RSLogix 500 using an internal relay bit. Includes truth tables, boolean equations, and verified.

Building a Modbus RTU Network with CompactLogix and DeltaV

Integrate Allen-Bradley CompactLogix, Caterpillar ATS, and generators into DeltaV DCS over Modbus RTU. Covers ProSoft MVI69-MCM, Miille DIN266 gateways.

ONS Instruction Not Energizing OTE in Studio 5000 Ladder Logic

ONS instruction fires but the OTE coil never latches in Studio 5000 because the one-shot is only true for one scan. Use OTL/OTU or seal-in logic instead.

Kinetix 5500 EtherNet/IP Network Switch Requirements and Topology

Configure Allen-Bradley Kinetix 5500 servo drives on EtherNet/IP. Covers CIP Sync, IEEE 1588 V2 timing, Stratix selection, DLR topology, and HMI.

Moving Average Filtering in DCS and PLC Analog Control

A moving-average filter is the sliding-window smoother most instrument engineers drop into DCS and PLC analog paths. Here is how the window works, how N and sample time set lag, and when a...