BECKHOFF

Beckhoff IP2321-B518 Fieldbus Box Digital I/O Module

SKU IP2321-B518

In stock
  • 12-month warranty
  • Free returns within 30 days
  • Manufacturer: BECKHOFF

  • Product No.: IP2321-B518

  • Country of origin:Germany

  • Product Type: Fieldbus I/O Modules

  • Payment: T/T, Western Union

  • Weight: 2000g

  • Shipping port: Xiamen

  • Warranty: 12 months

Description

Optimizing localized I/O distribution in CANopen networks, the Beckhoff IP2321-B518 coordinates high-density automation points directly in the field. This rugged fieldbus module integrates digital inputs and outputs into a single, compact form factor designed for decentralized mounting without an electrical enclosure. Equipped with high-performance CANopen communication capabilities, the module handles signal acquisition and actuator control in demanding environments while minimizing field cabling complexities via integrated loop-through network topologies.

Key Features

  • Distributed Architecture: Compact machine-mount design eliminates the need for terminal boxes or protective control panels.
  • Hybrid I/O Configuration: Equipped with 4 digital inputs (24 V DC with a 3 ms filter time) and 4 digital outputs (24 V DC with up to 2 A output capacity per channel).
  • Fieldbus Interface: Built-in CANopen transceiver supporting high-speed industrial bus networks.
  • Integrated T-Connector: Simplifies network wiring by allowing straight-line CANopen daisy-chaining without extra external splitters.
  • M8 Connection Interface: Standardized industrial M8 screw connections ensure highly reliable, vibration-proof wiring terminations.

Applications

  • Automotive assembly line conveyor networks and sorting systems.
  • Decentralized packaging machinery operating in high-vibration environments.
  • Machine tool automation requiring local, high-current solenoid and sensor aggregation.
  • Material handling systems utilizing distributed CANopen control nodes.

Technical Specifications

Specification Parameter Technical Value
Manufacturer Beckhoff
Model IP2321-B518
Fieldbus Protocol CANopen
Digital Inputs 4 Channels (24 V DC)
Input Filter Time 3 ms
Digital Outputs 4 Channels (24 V DC)
Max. Output Current 2 A per channel
I/O Connection M8 Screw Connectors
Fieldbus Connection M12 (with integrated T-connector)
Operating Voltage 24 V DC
Shipping Weight (Calculated) 2.0 kg

Empirical Engineering Insights

Alternative Models & Compatibility

The IP2321-B518 is tailored for CANopen-based control networks. When transitioning legacy plants from CANopen to EtherCAT architectures, this module cannot be directly converted to EtherCAT. Systems integration engineers should look toward the Beckhoff EP2338-0002 EtherCAT Box as a high-density alternative, or utilize a local EtherCAT-to-CANopen coupler gateway to retain existing IP2321-B518 field runs without replacing field-level physical wiring.

Application Pitfalls & Engineering Notes

While the module supports up to 2 A output current per channel, commissioning engineers must calculate the total aggregate load current for all active outputs. Exceeding the cumulative terminal current capabilities on the M8 auxiliary power feed can lead to localized thermal stress or unexpected low-voltage faults on the control side of the circuit, causing the module to shut down its outputs to protect internal solid-state components.

Commissioning & Wiring Tips

When deploying CANopen networks with the integrated T-connector, ensure that the network's physical ends are terminated with proper 120-Ohm resistors. To maintain the IP67 ingress protection rating, all unused M8 and M12 sockets must be sealed with Beckhoff protective caps and torqued to approximately 0.4 Nm. Over-tightening can crack the structural plastic threads, destroying the module's moisture-tight seal.

Installation Guidelines

CRITICAL SAFETY WARNING

Ensure all primary electrical systems, control voltages, and actuator auxiliary supplies are fully de-energized before mounting, wiring, or configuring the fieldbus module. Failure to isolate power lines can result in severe equipment damage, electrical shock, or unexpected mechanical movements of connected field machinery.

1

Securely mount the module directly to the machine frame using standard mounting holes, ensuring the mating surface is flat to prevent mechanical twisting when tightened.

2

Configure the CANopen node address using the protected rotary switches. Ensure node IDs do not overlap with other active fieldbus devices.

3

Connect the M8 digital inputs and outputs, paying careful attention to the keyway orientation of the sensor and actuator cables.

4

Attach the incoming and outgoing CANopen network links via the integrated T-connector. Verify that the bus line is properly terminated at the network physical boundaries.

5

Apply the 24 V DC system power supply and load supply lines, then run standard network diagnostic scans in your controller to verify node communication stability.

FAQ

Can this module be used directly in an EtherCAT control network?

No, this module is specifically configured for CANopen fieldbus communications. To integrate it into an EtherCAT network, you must use an EtherCAT-to-CANopen gateway or communication coupler.

What is the maximum output current limit per digital output channel?

Each digital output channel can drive up to 2.0 A of continuous load current at 24 V DC, which is suitable for directly controlling heavy solenoids, relays, and other direct field actuators.

How are unused I/O connections protected on this fieldbus box?

To maintain structural IP67 ingress protection against moisture and dust, all unassigned M8 and M12 ports must be capped using standard industrial-grade protective screw plugs tightened to 0.4 Nm.

Does the CANopen interface require an external termination resistor?

Yes, if this box is installed as the physical final device at the end of the CANopen network segment, a standard 120-Ohm termination resistor plug must be screwed into the auxiliary bus port.

View all FAQs →

Quantity
Shipping & Returns

Global Express Shipping

  • Standard Delivery: 4–6 business days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our technical warranty.
Reviews
1 of 1
Only 10 item(s) left in stock
Quantity
View full details

Global Express Shipping

  • Standard Delivery: 4-6 Business Days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries, including rapid delivery to Saudi Arabia and UAE.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our professional technical warranty.

Orders are processed and delivered Monday-Friday (excluding public holidays).


For full eligibility, restocking fees, and international return details, please view our official Refund & Return Policy .

TECHNICAL SPECIFICATIONS

Country of origin
Germany

Technical knowledge

First TwinCAT PLC Project on a Beckhoff IPC

Build and verify a first TwinCAT PLC project on a Beckhoff IPC. This checklist covers target selection, EtherCAT discovery, I/O mapping, safe activation, restart tests, and commissioning records.

Commissioning OPC UA in KEPServerEX: A Field Checklist

A practical commissioning sequence for KEPServerEX OPC UA connections: define data ownership, test tags locally, configure endpoint and certificate trust, limit access, then verify failure recovery...

Set a PLC Commissioning Laptop IP Without Losing Access

Commissioning an Ethernet-connected PLC often starts with the laptop, not the controller. Learn how to record existing settings, choose a temporary address, test connectivity, and restore the plant...

Designing Automation for Combustible Dust Hazards

Combustible dust controls require more than alarms. Learn how to map dust generation, select instrumentation, design interlocks, handle failed feedback, test safe states, and maintain the full...

Hairpin Stators: Benefits, Limits, and Inspection

Hairpin windings raise slot fill and support compact traction motors, but conductor geometry, AC losses, insulation damage, weld quality, and cooling determine whether the design meets its targets.

Using Ansible for Controlled SCADA Server Changes

Use Ansible to standardize SCADA server changes without expanding OT risk. This guide covers inventories, idempotent playbooks, staged testing, credentials, logging, and practical rollback controls.