BECKHOFF

BECKHOFF IP3112-B528 Fieldbus Box

SKU IP3112-B528

In stock
  • 12-month warranty
  • Free returns within 30 days
  • Manufacturer: BECKHOFF
  • Product No.: IP3112-B528
  • Origin Germany
  • Product Type: Fieldbus Boxes
  • Payment: T/T, Western Union
  • Weight: 2.0 kg
  • Dimensions: 2 x 2 x 0.25 mm
  • Shipping port: Xiamen
  • Warranty: 12 months

Tags

Quantity

Product Description

Description

Decentralized installation in harsh environments requires robust interfaces. The Beckhoff IP3112-B528 is a high-performance Fieldbus Box designed to connect digital and analog peripheral signals directly to DeviceNet networks. It functions without requiring a protective control cabinet, utilizing standard M12 and M8 connector interfaces to distribute power and fieldbus communications. The module supports automatic baud rate detection up to 500 kbaud, streamlining commissioning and enhancing diagnostic flexibility via KS2000 configuration software or explicit messaging protocols. Built to withstand challenging plant environments, it provides reliable data transfer and localized control interface distribution.

Features

  • Direct integration into DeviceNet networks with integrated T-connector functionality.
  • Flexible I/O communication modes including polling, cyclic, bit strobe, and change of state (COS).
  • Robust IP65/66/67 housing for decentralized, cabinet-free field installation.
  • Dual-channel M12 fieldbus connections for easy loop-through topology.
  • Efficient M8 power connectors for control voltage feeding and downstream distribution.

Applications

  • Automotive assembly and welding lines.
  • Material handling and conveyor systems.
  • Food and beverage processing plants.
  • Decentralized sensor and actuator networks in high-moisture or dusty environments.

Technical Specifications

Manufacturer BECKHOFF
Part Number/Model IP3112-B528
Fieldbus Interface 1 x M12 plug (5-pin), 1 x M12 socket (5-pin) with integrated tee-connector
Data Transfer Rates Automatic detection up to 500 kbaud
Data Transfer Medium Shielded copper cable, with power supply, typ. 2 x 2 x 0.25 mm²
Control Voltage Power Supply 24 V DC (-15% / +20%)
Power Supply Connection Feed: 1 x M8 male socket (4-pin); Downstream: 1 x M8 female socket (4-pin)
Box Supply Current 45 mA + current consumption of sensors (max. 0.5 A)
Electrical Isolation Control voltage/fieldbus: 500 V
Operating Temperature 0 to +55 degC
Storage Temperature -25 to +85 degC
Vibration/Shock Resistance Conforms to EN 60068-2-6 / EN 60068-2-27
EMC Immunity/Emission Conforms to EN 61000-6-2 / EN 61000-6-4
Protection Rating IP65/66/67 (conforms to EN 60529)
Shipping Weight 2 kg

Connections and Interfaces

Interface Type Connector Description Function
Fieldbus Input 1 x M12 plug, 5-pin DeviceNet incoming communication interface
Fieldbus Output 1 x M12 socket, 5-pin DeviceNet downstream loop-through connection
Power Feed 1 x M8 male socket, 4-pin Control voltage 24 V DC input
Power Downstream 1 x M8 female socket, 4-pin Control voltage daisy-chain to next box

Installation Guidelines

  • Mounting: Mount directly onto flat machine structures using the designated mounting holes. Ensure the surface is free of debris to maintain a secure seal.
  • Wiring: Use shielded copper cabling (typically 2 x 2 x 0.25 mm²) for DeviceNet transmission to preserve signal integrity and avoid EMI.
  • Grounding: Ensure the mounting surface or functional ground connection is correctly bonded to the plant's main ground potential.
  • IP Rating: Ensure all unused M8 and M12 interfaces are fitted with IP67-rated protective caps to maintain the unit's dust and moisture ingress resistance.

Compliance and Certifications

  • CE
  • UL
Shipping & Returns

Global Express Shipping

  • Standard Delivery: 4–6 business days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our technical warranty.
FAQ
What communication protocol is supported by the Beckhoff IP3112-B528?
The IP3112-B528 is designed for DeviceNet networks, supporting automatic baud rate detection up to 500 kbaud.
What are the power connections on this Fieldbus Box?
It features a 24 V DC control voltage input via a 4-pin M8 male socket, and a loop-through downstream connection via a 4-pin M8 female socket.
Can this module be mounted outside a control cabinet?
Yes, with an IP65/66/67 rating, this unit is fully protected against dust, low-pressure water jets, and temporary immersion, making it suitable for direct machine mounting.
What configurations are possible for the I/O signals?
Configuration can be completed either via the Beckhoff KS2000 software package or directly through the main PLC controller using explicit messaging.
Reviews

IP3112-B528

Stock & lead time on request

Call
1 of 1

BECKHOFF IP3112-B528 Fieldbus Box

Only 10 item(s) left in stock
  • Manufacturer: BECKHOFF

  • Product No.: IP3112-B528

  • Country of origin:Germany

  • Product Type: Fieldbus Boxes

  • Payment: T/T, Western Union

  • Weight: 2000g

  • Dimensions: 2 x 2 x 0.25 mm

  • Shipping port: Xiamen

  • Warranty: 12 months

Quantity
View full details

Description

Decentralized installation in harsh environments requires robust interfaces. The Beckhoff IP3112-B528 is a high-performance Fieldbus Box designed to connect digital and analog peripheral signals directly to DeviceNet networks. It functions without requiring a protective control cabinet, utilizing standard M12 and M8 connector interfaces to distribute power and fieldbus communications. The module supports automatic baud rate detection up to 500 kbaud, streamlining commissioning and enhancing diagnostic flexibility via KS2000 configuration software or explicit messaging protocols. Built to withstand challenging plant environments, it provides reliable data transfer and localized control interface distribution.

Features

  • Direct integration into DeviceNet networks with integrated T-connector functionality.
  • Flexible I/O communication modes including polling, cyclic, bit strobe, and change of state (COS).
  • Robust IP65/66/67 housing for decentralized, cabinet-free field installation.
  • Dual-channel M12 fieldbus connections for easy loop-through topology.
  • Efficient M8 power connectors for control voltage feeding and downstream distribution.

Applications

  • Automotive assembly and welding lines.
  • Material handling and conveyor systems.
  • Food and beverage processing plants.
  • Decentralized sensor and actuator networks in high-moisture or dusty environments.

Technical Specifications

Manufacturer BECKHOFF
Part Number/Model IP3112-B528
Fieldbus Interface 1 x M12 plug (5-pin), 1 x M12 socket (5-pin) with integrated tee-connector
Data Transfer Rates Automatic detection up to 500 kbaud
Data Transfer Medium Shielded copper cable, with power supply, typ. 2 x 2 x 0.25 mm²
Control Voltage Power Supply 24 V DC (-15% / +20%)
Power Supply Connection Feed: 1 x M8 male socket (4-pin); Downstream: 1 x M8 female socket (4-pin)
Box Supply Current 45 mA + current consumption of sensors (max. 0.5 A)
Electrical Isolation Control voltage/fieldbus: 500 V
Operating Temperature 0 to +55 degC
Storage Temperature -25 to +85 degC
Vibration/Shock Resistance Conforms to EN 60068-2-6 / EN 60068-2-27
EMC Immunity/Emission Conforms to EN 61000-6-2 / EN 61000-6-4
Protection Rating IP65/66/67 (conforms to EN 60529)
Shipping Weight 2 kg

Connections and Interfaces

Interface Type Connector Description Function
Fieldbus Input 1 x M12 plug, 5-pin DeviceNet incoming communication interface
Fieldbus Output 1 x M12 socket, 5-pin DeviceNet downstream loop-through connection
Power Feed 1 x M8 male socket, 4-pin Control voltage 24 V DC input
Power Downstream 1 x M8 female socket, 4-pin Control voltage daisy-chain to next box

Installation Guidelines

  • Mounting: Mount directly onto flat machine structures using the designated mounting holes. Ensure the surface is free of debris to maintain a secure seal.
  • Wiring: Use shielded copper cabling (typically 2 x 2 x 0.25 mm²) for DeviceNet transmission to preserve signal integrity and avoid EMI.
  • Grounding: Ensure the mounting surface or functional ground connection is correctly bonded to the plant's main ground potential.
  • IP Rating: Ensure all unused M8 and M12 interfaces are fitted with IP67-rated protective caps to maintain the unit's dust and moisture ingress resistance.

Compliance and Certifications

  • CE
  • UL

What communication protocol is supported by the Beckhoff IP3112-B528?

The IP3112-B528 is designed for DeviceNet networks, supporting automatic baud rate detection up to 500 kbaud.

What are the power connections on this Fieldbus Box?

It features a 24 V DC control voltage input via a 4-pin M8 male socket, and a loop-through downstream connection via a 4-pin M8 female socket.

Can this module be mounted outside a control cabinet?

Yes, with an IP65/66/67 rating, this unit is fully protected against dust, low-pressure water jets, and temporary immersion, making it suitable for direct machine mounting.

What configurations are possible for the I/O signals?

Configuration can be completed either via the Beckhoff KS2000 software package or directly through the main PLC controller using explicit messaging.

Global Express Shipping

  • Standard Delivery: 4-6 Business Days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries, including rapid delivery to Saudi Arabia and UAE.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our professional technical warranty.

Orders are processed and delivered Monday-Friday (excluding public holidays).


For full eligibility, restocking fees, and international return details, please view our official Refund & Return Policy .

TECHNICAL SPECIFICATIONS

Country of origin
Germany

Recently Viewed Products

Technical knowledge

Implementing 3-Switch XOR Ladder Logic with Internal Bit

Implement a 3-SPST switch XOR light circuit in LogixPro or RSLogix 500 using an internal relay bit. Includes truth tables, boolean equations, and verified.

Building a Modbus RTU Network with CompactLogix and DeltaV

Integrate Allen-Bradley CompactLogix, Caterpillar ATS, and generators into DeltaV DCS over Modbus RTU. Covers ProSoft MVI69-MCM, Miille DIN266 gateways.

ONS Instruction Not Energizing OTE in Studio 5000 Ladder Logic

ONS instruction fires but the OTE coil never latches in Studio 5000 because the one-shot is only true for one scan. Use OTL/OTU or seal-in logic instead.

Kinetix 5500 EtherNet/IP Network Switch Requirements and Topology

Configure Allen-Bradley Kinetix 5500 servo drives on EtherNet/IP. Covers CIP Sync, IEEE 1588 V2 timing, Stratix selection, DLR topology, and HMI.

Moving Average Filtering in DCS and PLC Analog Control

A moving-average filter is the sliding-window smoother most instrument engineers drop into DCS and PLC analog paths. Here is how the window works, how N and sample time set lag, and when a...

GE Mark VI Function Blocks for Gas Turbine Control Logic

On Frame 5–9 gas turbines, GE Mark VI and Mark VIe run control as function-block application software. This article maps process, protection, and sequencing functions—and what Toolbox ST access...