BECKHOFF KL1862-0010 16-Channel Digital Input Bus Terminal

SKU KL1862-0010

In stock
  • 12-month warranty
  • Free returns within 30 days
  • Manufacturer: BECKHOFF

  • Product No.: KL1862-0010

  • Country of origin:Germany

  • Product Type: Bus Terminal

  • Payment: T/T, Western Union

  • Weight: 500g

  • Shipping port: Xiamen

  • Warranty: 12 months

Product Overview

The KL1862-0010 (KL1862-0010) is a high-density, 16-channel digital input terminal engineered for efficient signal acquisition in industrial automation. Utilizing flat-ribbon cable connection technology, this terminal streamlines the wiring of complex control cabinets, making it an ideal choice for high-volume manufacturing lines and multi-point sensing applications. By providing reliable ground-switching input monitoring, the KL1862-0010 ensures consistent data integrity in demanding environments such as process control and heavy assembly, significantly reducing cabinet installation time and maintenance overhead.

Technical Configuration

This module provides sixteen digital input channels specifically designed for ground-switching configurations. It operates on a nominal 24 VDC supply and is built to withstand industrial electromagnetic conditions through an integrated 3.0 ms input filter, which mitigates transient noise and contact bounce. The terminal is architected for seamless integration into the standard K-bus system, requiring no manual addressing or complex configuration, thereby enabling plug-and-play deployment. With 500 V electrical isolation between the K-bus and field potential, the module provides robust protection for the central controller against field-side electrical faults.

Technical Specifications

Feature Specification
Model KL1862-0010
Brand BECKHOFF
Number of Inputs 16
Connection Type Flat-ribbon cable
Input Type Ground switching
Nominal Voltage 24 VDC (-15% to +20%)
Input Filter Typ 3.0 ms
Electrical Isolation 500 V
Operating Temp 0 to 55 deg C
Weight Approx 50 g
Protection Class IP20

FAQs

What is the specific advantage of the flat-ribbon cable connection?

The flat-ribbon interface allows for rapid, multi-channel wiring using pre-assembled cables, which significantly reduces the physical space required and decreases the time needed for cabinet assembly.

Does this terminal require configuration in the TwinCAT system?

No, the KL1862-0010 is a standard digital input terminal that requires no address or configuration settings; it is automatically mapped into the process image upon connection to the K-bus.

What does the ground-switching (negative logic) input mean?

In this configuration, the input is triggered when it is connected to ground (0 V). The terminal recognizes a "1" signal in the voltage range of 0 to 7 V.

Is this terminal suitable for use in explosive atmospheres?

Yes, the terminal carries ATEX and IECEx certifications (Ex ec IIC T4 Gc), allowing for installation in specific hazardous zones when used in accordance with the provided safety documentation.

Installation and Operational Guidelines

  • Wiring Precision: Ensure the flat-ribbon cable is properly oriented and fully seated in the header to prevent intermittent connections. Use high-quality IDC (Insulation Displacement Connector) tools if crimping your own cable assemblies to ensure gas-tight contacts.

  • Thermal Management: Although the terminal is compact (50 g), maintain adequate vertical clearance within the control cabinet to facilitate air circulation, especially when multiple high-density modules are mounted side-by-side. Avoid placement near high-power heating elements or variable frequency drives.

  • Signal Shielding: To ensure compliance with EMC standards (EN 61000-6-2/4), keep input signal cables separated from high-voltage power lines. If the flat-ribbon cable length exceeds standard limits, consider adding external surge protection or ensuring the cabinet is properly grounded to mitigate common-mode noise.

 

Quantity
Shipping & Returns

Global Express Shipping

  • Standard Delivery: 4–6 business days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our technical warranty.
Reviews
1 of 1
Only 10 item(s) left in stock
Quantity
View full details

Global Express Shipping

  • Standard Delivery: 4-6 Business Days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries, including rapid delivery to Saudi Arabia and UAE.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our professional technical warranty.

Orders are processed and delivered Monday-Friday (excluding public holidays).


For full eligibility, restocking fees, and international return details, please view our official Refund & Return Policy .

TECHNICAL SPECIFICATIONS

Color pattern
Greyish White
Country of origin
Germany
Power source
DC Power

Technical knowledge

Moving TwinCAT 3 Licenses with C9900-L100: Build and Device Checks

Before moving a TwinCAT 3 license with a Beckhoff C9900-L100, verify the TwinCAT build, XML device description, exact order code and cabinet limits.

Replacing a Beckhoff EL4032: Wiring and Output Checks

A field checklist for replacing a Beckhoff EL4032, covering the ±10 V load, terminal map, power contacts, EtherCAT state, and watchdog behavior.

Replacing Yokogawa AAI835: Wiring and Barrier Checks Before Swap

Before replacing a Yokogawa AAI835, verify the 4-in/4-out channel map, power-loss loop behavior, barrier type, output load, cable, and redundancy.

ABB PM891K01 Replacement: Check Redundancy Before Ordering

ABB PM891K01 article 3BSE053241R1 is the non-redundant AC 800M processor kit. Use this field checklist before replacement.

ABB TP853 Replacement Checks for CI853/CI855/CI857/CI861

Replacement checks for ABB TP853 3BSE018126R1: identify the installed CI853, CI855, CI857, or CI861 interface, record wiring, and verify communication after installation.

5069-L330ERMS2 Startup Checks: RTBs, I/O, and Motion Limits

Engineering checks for the Allen-Bradley 5069-L330ERMS2: controller capacity, separate RTB kits, local I/O limits, network-node limits, and motion-axis count.