Description

The KL9520 is an AS-Interface potential feed terminal with an integrated filter, engineered for seamless integration into the Beckhoff Bus Terminal system. This terminal is designed to provide potential distribution for AS-Interface systems, supporting input and output voltages of up to 35 V DC with a maximum current load of 2 A. Housed in a compact terminal design, the KL9520 facilitates efficient power distribution within DIN rail-mounted automation architectures.

Features

  • Integrated filter for AS-Interface potential feed
  • Supports input and output voltages up to 35 V DC
  • Maximum current load of 2 A
  • Maintenance-free: No address or configuration settings required
  • Compact housing compatible with standard Bus Terminal systems
  • DIN rail mounting with double slot and key connection for robust side-by-side assembly

Technical Specifications

Feature Specification
Manufacturer Beckhoff
Product Type AS-Interface Potential Feed Terminal
Voltage Range Up to 35 V DC (Input/Output)
Max. Current Load 2 A
Operating Temperature 0…+55 degC
Storage Temperature -25…+85 degC
Protection Rating IP20
Dimensions 12 mm x 100 mm x 68 mm
Weight Approx. 90 g
Mounting 35 mm DIN rail (EN 60715)
Approvals CE

Installation Guidelines

  • Mounting: Secure the terminal onto a 35 mm DIN rail; utilize the integrated lock for stability.
  • Side-by-Side Mounting: Ensure proper connection using the double slot and key mechanism for reliable power contact alignment.
  • Wiring: Supports solid (s), stranded (st), and ferrule (f) conductors. Use a screwdriver for spring-actuated terminal connections.
  • Connection Cross-sections:
    • Solid/Stranded: 0.08…2.5 mm² (AWG 28…14)
    • With Ferrule: 0.14…1.5 mm² (AWG 26…16)
  • Stripping Length: 8…9 mm.
  • Maintenance: Ensure the installation environment maintains humidity levels below 95% (non-condensing) and adheres to EN 60068 standards for vibration/shock.

FAQ

What is the primary function of the KL9520?

The KL9520 is a potential feed terminal with an integrated filter designed for AS-Interface systems.

What is the maximum voltage supported by this terminal?

The terminal supports input and output voltages up to 35 V DC.

Does the KL9520 require address configuration?

No, the terminal does not require any address or configuration settings.

What is the maximum current load for the power contacts?

The current load for power contacts is 10 A, while the terminal itself supports a maximum load of 2 A.

View all FAQs →

Quantity
Shipping & Returns

Global Express Shipping

  • Standard Delivery: 4–6 business days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our technical warranty.
Reviews
1 of 1
Only 10 item(s) left in stock
Quantity
View full details

Global Express Shipping

  • Standard Delivery: 4-6 Business Days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries, including rapid delivery to Saudi Arabia and UAE.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our professional technical warranty.

Orders are processed and delivered Monday-Friday (excluding public holidays).


For full eligibility, restocking fees, and international return details, please view our official Refund & Return Policy .

TECHNICAL SPECIFICATIONS

Color pattern
Greyish White
Country of origin
Germany

Technical knowledge

Diagnosing DeltaV SE5009 Power Problems Before Replacement

A field checklist for separating 24 VDC input, carrier bus, output derating and alarm-contact faults before replacing an Emerson SE5009.

Commissioning Quantum Inputs with the 140XSM00200 Simulator

A controlled commissioning method for using the 140XSM00200 simulator to verify Modicon Quantum input mapping and interlocks before reconnecting field wiring.

Commissioning PLX32-EIP-MBTCP: Subnets, Registers, and RPI

A commissioning checklist for the ProSoft PLX32-EIP-MBTCP covering subnet separation, register contracts, EtherNet/IP timing, failure tests and replacement records.

Diagnosing IC693MDL916 Relay Outputs Before Module Replacement

A field checklist for IC693MDL916 relay commands, terminal blocks, load current, switching rate and contact-side measurements.

Troubleshooting Beckhoff KL1512 Counter Inputs and Mapping

A field checklist for KL1512 signal thresholds, counter direction, process data and the KL1512-to-KS1512 wiring difference.

Troubleshooting Beckhoff EPP2008-0001 Output Faults

A field checklist for EPP2008-0001 current limits, supply voltage, channel LEDs, connector coding and load-related output faults.