Beckhoff KL9520 AS-Interface Potential Feed Terminal

Beckhoff KL9520 AS-Interface Potential Feed Terminal

Only 10 item(s) left in stock
  • Manufacturer: BECKHOFF

  • Product No.: KL9520

  • Country of origin:Germany

  • Product Type: Potential Feed Terminals

  • Payment: T/T, Western Union

  • Weight: 2000g

  • Dimensions: 12 mm x 100 mm x 68 mm

  • Shipping port: Xiamen

  • Warranty: 12 months

Quantity
View full details

Description

The KL9520 is an AS-Interface potential feed terminal with an integrated filter, engineered for seamless integration into the Beckhoff Bus Terminal system. This terminal is designed to provide potential distribution for AS-Interface systems, supporting input and output voltages of up to 35 V DC with a maximum current load of 2 A. Housed in a compact terminal design, the KL9520 facilitates efficient power distribution within DIN rail-mounted automation architectures.

Features

  • Integrated filter for AS-Interface potential feed
  • Supports input and output voltages up to 35 V DC
  • Maximum current load of 2 A
  • Maintenance-free: No address or configuration settings required
  • Compact housing compatible with standard Bus Terminal systems
  • DIN rail mounting with double slot and key connection for robust side-by-side assembly

Technical Specifications

Feature Specification
Manufacturer Beckhoff
Product Type AS-Interface Potential Feed Terminal
Voltage Range Up to 35 V DC (Input/Output)
Max. Current Load 2 A
Operating Temperature 0…+55 degC
Storage Temperature -25…+85 degC
Protection Rating IP20
Dimensions 12 mm x 100 mm x 68 mm
Weight Approx. 90 g
Mounting 35 mm DIN rail (EN 60715)
Approvals CE

Installation Guidelines

  • Mounting: Secure the terminal onto a 35 mm DIN rail; utilize the integrated lock for stability.
  • Side-by-Side Mounting: Ensure proper connection using the double slot and key mechanism for reliable power contact alignment.
  • Wiring: Supports solid (s), stranded (st), and ferrule (f) conductors. Use a screwdriver for spring-actuated terminal connections.
  • Connection Cross-sections:
    • Solid/Stranded: 0.08…2.5 mm² (AWG 28…14)
    • With Ferrule: 0.14…1.5 mm² (AWG 26…16)
  • Stripping Length: 8…9 mm.
  • Maintenance: Ensure the installation environment maintains humidity levels below 95% (non-condensing) and adheres to EN 60068 standards for vibration/shock.

What is the primary function of the KL9520?

The KL9520 is a potential feed terminal with an integrated filter designed for AS-Interface systems.

What is the maximum voltage supported by this terminal?

The terminal supports input and output voltages up to 35 V DC.

Does the KL9520 require address configuration?

No, the terminal does not require any address or configuration settings.

What is the maximum current load for the power contacts?

The current load for power contacts is 10 A, while the terminal itself supports a maximum load of 2 A.

Global Express Shipping

  • Standard Delivery: 4-6 Business Days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries, including rapid delivery to Saudi Arabia and UAE.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our professional technical warranty.

Orders are processed and delivered Monday-Friday (excluding public holidays).


For full eligibility, restocking fees, and international return details, please view our official Refund & Return Policy .

TECHNICAL SPECIFICATIONS

Color pattern
Greyish White
Country of origin
Germany

Recently Viewed Products

Technical knowledge

Modernizing Bailey INFI 90 Symphony HMIs Running on OpenVMS Alpha

A practical guide to replacing aging Bailey Symphony operator stations running on OpenVMS Alpha. It compares Alpha emulation, OpenVMS x86 migration, OPC re-platforming, and phased ABB modernization.

Why Maintenance Data Is Essential for Industrial Reliability

Maintenance data connects work orders, sensor signals, asset history, costs, and technician knowledge. Used well, it improves planning, reliability, predictive maintenance, spare-parts control, and...

Electric Actuators Designed to Replace Fluid Power Systems: A Practical Industrial Automation Guide

This article explains how integrated electric actuators, such as SMC’s e-Actuator series, are transforming industrial motion control by replacing traditional pneumatic and hydraulic systems. It...

Math Operations Using OpenPLC for Industrial Automation Applications

This article explains how PLC systems perform core mathematical operations such as addition, subtraction, multiplication, division, modulo, and exponentiation within industrial automation. It shows...

Advanced Boolean Logic with FBD PLC Programming: Practical Industrial Applications Beyond Basic Logic

The article explains several advanced Boolean logic functions used in PLC programming beyond basic AND, OR, and NOT operations. It covers how tools like truth tables, multiplexers, pulse generators,...

Boolean Logic in PLC Programming: Understanding FBD Logic Gates

Boolean logic is the foundation of every PLC program. From simple machine controls to complex industrial automation systems, logic gates determine how controllers respond to changing inputs and...