The BECKHOFF KM1018-0000 is a high-density Bus Terminal module designed to accommodate 64 digital inputs within a compact housing. Operating at a nominal voltage of 24 V DC, this module acts as a space-saving interface within the Beckhoff I/O system, transmitting electrically isolated signals directly to higher-level automation units via the K-bus. By integrating 64 channels into a single physical unit, it significantly reduces control cabinet space requirements while maintaining accurate signal acquisition.

As the base configuration variant (-0000), the BECKHOFF KM1018-0000 is delivered without pluggable front connector blocks. This design enables system engineers to choose the appropriate wiring technology for their installation, including 1-wire or 3-wire plug-in connector strips with or without diagnostic status LEDs. The physical assembly mounts directly to standard DIN rails and interlocks with adjacent terminals for structural and electrical stability.

Features

  • High-density interface providing 64 digital input channels.
  • Fast signal acquisition with a typical input filter limit of 0.2 ms.
  • Electrical isolation of 500 V between the K-bus and the field potential.
  • Flexible wiring configuration utilizing a pluggable connector level (connector blocks ordered separately).
  • Direct installation on standard 35 mm DIN rails using a secure double slot and key locking system.
  • Low current consumption from the K-bus to optimize system energy efficiency.

Applications

  • High-density digital signal acquisition in space-constrained control cabinets.
  • Industrial automation systems requiring fast response times for digital sensor inputs.
  • Machine tool, packaging machinery, and manufacturing line control via Beckhoff K-bus networks.

Ordering Information

Model Variant Description
KM1018-0000 64-channel digital input module, 24 V DC, 0.2 ms filter, without connector blocks
KM1018-0001 64-channel digital input module, 24 V DC, 0.2 ms filter, includes 1-wire connectors
KM1018-0002 64-channel digital input module, 24 V DC, 0.2 ms filter, includes 1-wire connectors with status LEDs
KM1018-0004 64-channel digital input module, 24 V DC, 0.2 ms filter, includes 3-wire connectors with status LEDs

Technical Specifications

General and Mechanical

Parameter Specification
Manufacturer BECKHOFF
Model Number KM1018-0000
Product Type Bus Terminal Module
Number of Inputs 64 (8 x 8)
Design Form Compact terminal module with pluggable wiring level
Dimensions (W x H x D) 123 mm x 100 mm x 55 mm
Mounting 35 mm DIN rail (conforming to EN 60715) with lock
Permissible Conductor Sizes 0.08 to 1.5 mm² (stranded or solid wire)
Stripping Length 8 mm

Electrical and Signal

Parameter Specification
Nominal Voltage 24 V DC (-15% / +20%)
"0" Signal Voltage -3 to +5 V (conforming to EN 61131-2, type 1)
"1" Signal Voltage 15 to 30 V (conforming to EN 61131-2, type 1)
Input Filter Time typ. 0.2 ms
Input Current typ. 5 mA
Current Consumption K-Bus typ. 3 mA
Electrical Isolation 500 V (K-bus to field potential)
Process Image Bit Width 64 inputs

Environmental

Parameter Specification
Operating Temperature 0 to +55 Celsius
Storage Temperature -25 to +85 Celsius
Relative Humidity 95%, non-condensing
Vibration / Shock Resistance Conforms to EN 60068-2-6 / EN 60068-2-27
EMC Immunity / Emission Conforms to EN 61000-6-2 / EN 61000-6-4
Protection Class IP20
Approvals CE

Installation Guidelines

  1. Verify overall system compatibility and ensure the power supply is completely de-energized before beginning installation.
  2. Mount the BECKHOFF KM1018-0000 module onto a standard 35 mm DIN rail (EN 60715) by sliding it into position. Ensure the side-by-side connection to adjacent terminals is secured using the double slot and key locking structure.
  3. Verify that the mechanical K-bus contacts engage properly with the neighboring module.
  4. Insert the compatible pluggable connector blocks (ordered separately) into the front of the terminal module.
  5. Perform field wiring using appropriate conductors (0.08 to 1.5 mm²), stripping the insulation back exactly 8 mm.
  6. Apply field-side 24 V DC power and execute a system configuration scan using TwinCAT System Manager to configure the process image.

FAQ

Does the BECKHOFF KM1018-0000 include the pluggable terminal connectors?

No, the BECKHOFF KM1018-0000 is the base module variant supplied without pluggable connector blocks, which must be selected and purchased separately based on your application wiring requirements (such as 1-wire or 3-wire interfaces).

What is the typical input filter time of the BECKHOFF KM1018-0000?

The BECKHOFF KM1018-0000 features a typical input filter response time of 0.2 ms, making it suitable for applications requiring rapid digital signal acquisition.

How many digital input channels are available on the BECKHOFF KM1018-0000?

The BECKHOFF KM1018-0000 provides 64 digital input channels arranged in eight groups of eight, offering high-density signal integration in a compact 123 mm wide housing.

What wire sizes are compatible with the BECKHOFF KM1018-0000 connection level?

When using compatible pluggable connector blocks with the BECKHOFF KM1018-0000, you can connect solid or stranded conductors with cross-sections ranging from 0.08 to 1.5 mm².

View all FAQs →

Quantity
Shipping & Returns

Global Express Shipping

  • Standard Delivery: 4–6 business days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our technical warranty.
Reviews
1 of 1
Only 10 item(s) left in stock
Quantity
View full details

Global Express Shipping

  • Standard Delivery: 4-6 Business Days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries, including rapid delivery to Saudi Arabia and UAE.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our professional technical warranty.

Orders are processed and delivered Monday-Friday (excluding public holidays).


For full eligibility, restocking fees, and international return details, please view our official Refund & Return Policy .

TECHNICAL SPECIFICATIONS

Country of origin
Germany

Technical knowledge

1756-OF4 Output Wrong? Check Mode, RTB, and Scaling First

A field-first diagnostic sequence for 1756-OF4 analog output problems: channel mode, removable terminal block, scaling, and controlled electrical checks.

1746-OA8 vs 1746-OA16: Output Count and Current Limits

A direct comparison of 1746-OA8 and 1746-OA16 output count, common grouping, backplane current and temperature-derated load limits.

Replacing a 1761-NET-DNI: Capture These Settings First

A field checklist for recording the 1761-NET-DNI hardware series, firmware, EDS file, DF1 settings, DeviceNet address and messaging configuration before replacement.

EL3062 vs EL3062-0030: The Input Range Changes

The EL3062 is a 0–10 V EtherCAT terminal. The EL3062-0030 is a 0–30 V variant. This checklist covers identification, scaling and commissioning.

Replacing a 1769-OW8: Checks Before Moving Relay Loads

A field checklist for replacing Allen-Bradley 1769-OW8 relay output modules without losing load-group, wiring, and commissioning details.

PLC I/O Modules: Wiring, Load, and Isolation Checks

A field checklist for matching PLC digital and analog I/O to sensors, loads, commons, isolation groups, filters, and replacement settings.