Product Overview

The KS3051 (KS3051) is a high-precision, 1-channel analog input terminal from the Beckhoff KS series, specifically engineered for the acquisition of 4…20 mA standard signals. Featuring a pluggable wiring level, this terminal is optimized for applications where rapid field maintenance and modular machine design are critical. The KS3051 offers high-speed signal conversion and includes an integrated sensor supply, making it a versatile interface for pressure, flow, and temperature transmitters in industrial process control. By ensuring accurate 12-bit data conversion and robust galvanic isolation, it minimizes noise-related measurement drift, contributing to stable control loops and reduced equipment downtime.

Technical Configuration

The KS3051 hardware architecture is centered on a single-ended 4…20 mA input stage with a 12-bit resolution. The internal input resistance is 80 Ohm plus a 0.7 V diode voltage drop, ensuring compatibility with standard passive and active sensor loops. A key advantage of this module is the integrated sensor supply, which simplifies external power distribution for field transmitters. The terminal provides 500 V electrical isolation between the K-bus and field potential, protecting the control system from potential ground loops or voltage spikes originating in the field.

Technical Specifications

Feature Specification
Model KS3051
Brand BECKHOFF
Origin Germany
Number of Inputs 1
Signal Current 4 to 20 mA
Resolution 12 bit
Conversion Time ~ 1 ms
Measuring Error < ±0.3 %
Operating Temperature 0 to 55 deg C
Dimensions 1.2 cm x 10.0 cm x 6.8 cm
Protection Rating IP20

FAQs

What is the benefit of the pluggable wiring level on the KS3051?

The pluggable wiring level allows the terminal block to be removed and replaced without disconnecting the individual field wires. This significantly reduces downtime during component replacement and ensures that wiring errors are minimized during maintenance.

Does the KS3051 require an external power supply for the transmitter?

No, the terminal is equipped with an integrated sensor supply. This feature allows you to power your 4…20 mA transmitter directly through the terminal’s connection points, reducing the need for external power supplies or distribution blocks.

Is this terminal suitable for use in explosive atmospheres?

Yes, the KS3051 carries ATEX certification (II 3 G Ex nA IIC T4 Gc), meaning it is approved for use in Zone 2 hazardous areas, provided it is housed within an appropriately rated enclosure.

Installation and Operational Recommendations

  • Shielding and Grounding: To achieve the stated measuring accuracy (< ±0.3 %), ensure that the signal cable shield is terminated at the cabinet’s central PE point. Avoid routing 4…20 mA signal lines parallel to high-voltage power cables to prevent electromagnetic interference.
  • Pluggable Connector Maintenance: During installation, ensure the pluggable wiring level is fully seated and locked into the terminal housing. If the module is subjected to high-vibration environments, periodically verify the integrity of the plug connection to prevent intermittent signal loss.
  • Wiring Technique: When stripping conductors, use the recommended 9–10 mm length. Ensure that no stray copper strands extend beyond the terminal entry, as this could cause short circuits within the high-density terminal block.
Quantity
Shipping &amp; Returns

Global Express Shipping

  • Standard Delivery: 4–6 business days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our technical warranty.
Reviews
1 of 1
Only 10 item(s) left in stock
Quantity
View full details

Global Express Shipping

  • Standard Delivery: 4-6 Business Days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries, including rapid delivery to Saudi Arabia and UAE.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our professional technical warranty.

Orders are processed and delivered Monday-Friday (excluding public holidays).


For full eligibility, restocking fees, and international return details, please view our official Refund & Return Policy .

TECHNICAL SPECIFICATIONS

Color pattern
Greyish White
Country of origin
Germany

Technical knowledge

Derivative Action in PID Control Without Noise Problems

Learn what derivative action contributes to a PID loop, why it can amplify measurement noise and setpoint changes, and how filtering, sampling, and staged tests make D tuning safer.

Designing Industrial Networks That Stay Troubleshootable

A practical guide to segmenting, documenting, and testing industrial Ethernet networks so plant teams can isolate faults quickly, control change, and expand without creating fragile dependencies.

Commissioning IO-Link From Master Ports to IODD Data

Commission IO-Link systematically from master addressing and port modes through IODD selection, PLC byte mapping, parameter backups, device validation, and failure-injection tests.

PowerFlex Dynamic Braking Resistor Design and Testing

A practical PowerFlex braking guide covering regenerative energy, resistor resistance and duty cycle, thermal protection, model-specific parameters, and measured commissioning tests.

Engineering Industrial Joystick Controls for Safe Motion

An industrial joystick is only the first element in a safe motion command chain. This guide covers sensing choices, wiring, signal validation, PLC logic, restart behavior, and commissioning for...

Seeing PID Behavior Before Tuning the Loop

PID tuning becomes safer when engineers can see how proportional, integral, and derivative actions reshape error, output, and response over time. This guide turns live trends into a disciplined...