BECKHOFF

BECKHOFF KS3404 Bus Terminal

SKU KS3404

In stock
  • 12-month warranty
  • Free returns within 30 days
  • Manufacturer: BECKHOFF
  • Product No.: KS3404
  • Origin Germany
  • Product Type: Bus Terminals
  • Payment: T/T, Western Union
  • Weight: 0.075 kg
  • Dimensions: 12 mm x 100 mm x 68 mm
  • Shipping port: Xiamen
  • Warranty: 12 months

Tags

Quantity

Product Description

Description

The BECKHOFF KS3404 is a 4-channel analog input Bus Terminal designed to process signals in the -10 V to +10 V range with high accuracy. Operating within the Beckhoff K-bus system architecture, this terminal converts analog physical values from the field level into digital process data for the higher-level controller. It features single-ended input technology and a 12-bit resolution, ensuring reliable signal acquisition for standard industrial automation tasks.

A key distinguishing feature of the BECKHOFF KS3404 is its pluggable wiring level. Unlike standard KL-series terminals, the KS-series design allows the complete wiring harness to be plugged or unplugged as a single unit. This design minimizes downtime during maintenance, simplifies pre-wiring steps, and prevents potential wiring errors during terminal replacement.

Features

  • 4 single-ended analog inputs designed for -10 V to +10 V signal ranges.
  • 12-bit resolution (11-bit resolution when configured for the 0 to 10 V range).
  • Pluggable wiring level (KS series housing) for efficient installation and servicing.
  • 500 V electrical isolation between the K-bus and the signal level.
  • No hardware address or configuration switches required, enabling automatic configuration via the bus coupler.
  • Compact 12 mm housing width to optimize control cabinet space.

Applications

  • Analog voltage monitoring in machine control and industrial process environments.
  • Integration of analog sensors and transducers with standard voltage outputs into K-bus I/O systems.
  • Control cabinet builds requiring pluggable terminal connections for rapid deployment or modular machine designs.

Technical Specifications

General

Manufacturer BECKHOFF
Model KS3404
Product Type Bus Terminal (Analog Input)
Design Form Terminal housing with pluggable wiring level

Signal and I/O

Number of Inputs 4
Signal Voltage Range -10 V to +10 V
Input Technology Single-ended
Resolution 12 bit (11 bit for 0 to 10 V range)
Internal Resistance > 130 kOhm
Measuring Error < +-0.3% (relative to full scale value)
Conversion Time ~ 2 ms
Bit Width in Process Image Input: 4 x 16-bit data (4 x 8-bit control/status optional)

Electrical

Power Supply Via the K-bus
Current Consumption K-bus Typical 100 mA
Current Consumption Power Contacts None (not used)
Current Load Power Contacts (Imax) 10 A
Electrical Isolation 500 V (K-bus to signal voltage)

Connection

Wiring Connection Spring actuation by screwdriver
Pluggable Wiring Level Yes
Conductor Cross-section (Solid) 0.08 to 1.5 mm² (AWG 28 to 16)
Conductor Cross-section (Stranded) 0.08 to 1.5 mm² (AWG 28 to 16)
Conductor Cross-section (Flexible) 0.14 to 1.5 mm² (AWG 26 to 16)
Stripping Length 9 to 10 mm

Mechanical & Environmental

Dimensions (W x H x D) 12 mm x 100 mm x 68 mm
Weight 0.075 kg
Housing Material Polycarbonate
Mounting 35 mm DIN rail (EN 60715) with lock
Operating Temperature -25 to +60 degC
Storage Temperature -40 to +85 degC
Relative Humidity 95%, non-condensing
Protection Class IP20
Vibration/Shock Resistance Conforms to EN 60068-2-6/EN 60068-2-27
EMC Immunity/Emission Conforms to EN 61000-6-2/EN 61000-6-4

Compliance and Certifications

Approvals and Markings CE, UL, ATEX, DNV GL
Ex Marking II 3 G Ex nA IIC T4 Gc

Installation Guidelines

  1. Power Off: Disconnect and lock out all power sources feeding the Bus Terminal system and field devices before installation or removal.
  2. Mounting: Snap the terminal onto a standard 35 mm DIN rail (conforming to EN 60715). Ensure the double slot-and-key connection is securely aligned with adjacent terminals.
  3. Plugging Wiring Level: Insert the wired connector block into the terminal housing until it clicks into place.
  4. Wiring: Connect the signal wires according to standard single-ended voltage measurement layouts using a screwdriver to actuate the spring-clamp terminals. Strip wire insulation back 9 to 10 mm.
  5. System Verification: Ensure correct installation of shield connections where necessary to protect sensitive analog signals from external electromagnetic interference.

Replacement Recommendations

When replacing an existing BECKHOFF KS3404, the pluggable wiring level allows maintenance personnel to swap the physical electronics block without disconnecting individual wires from the spring clamps. Ensure that the bus segment is fully de-energized before removing the connector block or pulling the terminal off the DIN rail. Verify that the successor or replacement model matches the configuration requirements in the TwinCAT system manager.

Shipping &amp; Returns

Global Express Shipping

  • Standard Delivery: 4–6 business days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our technical warranty.
FAQ
What is the primary function of the BECKHOFF KS3404?
The BECKHOFF KS3404 is a 4-channel analog input Bus Terminal designed to measure analog standard signals in the -10 V to +10 V range, transmitting them with a 12-bit resolution to the higher-level controller via the K-bus.
What is the difference between the KL3404 and the KS3404 terminals?
The BECKHOFF KS3404 features a pluggable wiring level, allowing the entire terminal block's wiring harness to be plugged or unplugged as a single assembly, whereas the standard KL3404 uses fixed wiring clamps directly integrated into the terminal housing.
Does the BECKHOFF KS3404 require power contacts for its operation?
No, the BECKHOFF KS3404 does not draw current from the power contacts; its internal electronic circuitry is powered exclusively via the K-bus, drawing a typical current of 100 mA.
What level of electrical isolation does the BECKHOFF KS3404 provide?
The BECKHOFF KS3404 provides 500 V of electrical isolation between the K-bus communication lines and the field-side analog signal lines.
What is the measurement resolution of the BECKHOFF KS3404?
The BECKHOFF KS3404 provides a 12-bit resolution for the full -10 V to +10 V range, which adjusts to an 11-bit resolution when utilizing a 0 to 10 V range.
Reviews

KS3404

Stock &amp; lead time on request

Call
1 of 1

BECKHOFF KS3404 Bus Terminal

Only 10 item(s) left in stock
  • Manufacturer: BECKHOFF

  • Product No.: KS3404

  • Country of origin:Germany

  • Product Type: Bus Terminals

  • Payment: T/T, Western Union

  • Weight: 75g

  • Dimensions: 12 mm x 100 mm x 68 mm

  • Shipping port: Xiamen

  • Warranty: 12 months

Quantity
View full details

Product Description

Description

The BECKHOFF KS3404 is a 4-channel analog input Bus Terminal designed to process signals in the -10 V to +10 V range with high accuracy. Operating within the Beckhoff K-bus system architecture, this terminal converts analog physical values from the field level into digital process data for the higher-level controller. It features single-ended input technology and a 12-bit resolution, ensuring reliable signal acquisition for standard industrial automation tasks.

A key distinguishing feature of the BECKHOFF KS3404 is its pluggable wiring level. Unlike standard KL-series terminals, the KS-series design allows the complete wiring harness to be plugged or unplugged as a single unit. This design minimizes downtime during maintenance, simplifies pre-wiring steps, and prevents potential wiring errors during terminal replacement.

Features

  • 4 single-ended analog inputs designed for -10 V to +10 V signal ranges.
  • 12-bit resolution (11-bit resolution when configured for the 0 to 10 V range).
  • Pluggable wiring level (KS series housing) for efficient installation and servicing.
  • 500 V electrical isolation between the K-bus and the signal level.
  • No hardware address or configuration switches required, enabling automatic configuration via the bus coupler.
  • Compact 12 mm housing width to optimize control cabinet space.

Applications

  • Analog voltage monitoring in machine control and industrial process environments.
  • Integration of analog sensors and transducers with standard voltage outputs into K-bus I/O systems.
  • Control cabinet builds requiring pluggable terminal connections for rapid deployment or modular machine designs.

Technical Specifications

General

Manufacturer BECKHOFF
Model KS3404
Product Type Bus Terminal (Analog Input)
Design Form Terminal housing with pluggable wiring level

Signal and I/O

Number of Inputs 4
Signal Voltage Range -10 V to +10 V
Input Technology Single-ended
Resolution 12 bit (11 bit for 0 to 10 V range)
Internal Resistance > 130 kOhm
Measuring Error < +-0.3% (relative to full scale value)
Conversion Time ~ 2 ms
Bit Width in Process Image Input: 4 x 16-bit data (4 x 8-bit control/status optional)

Electrical

Power Supply Via the K-bus
Current Consumption K-bus Typical 100 mA
Current Consumption Power Contacts None (not used)
Current Load Power Contacts (Imax) 10 A
Electrical Isolation 500 V (K-bus to signal voltage)

Connection

Wiring Connection Spring actuation by screwdriver
Pluggable Wiring Level Yes
Conductor Cross-section (Solid) 0.08 to 1.5 mm² (AWG 28 to 16)
Conductor Cross-section (Stranded) 0.08 to 1.5 mm² (AWG 28 to 16)
Conductor Cross-section (Flexible) 0.14 to 1.5 mm² (AWG 26 to 16)
Stripping Length 9 to 10 mm

Mechanical & Environmental

Dimensions (W x H x D) 12 mm x 100 mm x 68 mm
Weight 0.075 kg
Housing Material Polycarbonate
Mounting 35 mm DIN rail (EN 60715) with lock
Operating Temperature -25 to +60 degC
Storage Temperature -40 to +85 degC
Relative Humidity 95%, non-condensing
Protection Class IP20
Vibration/Shock Resistance Conforms to EN 60068-2-6/EN 60068-2-27
EMC Immunity/Emission Conforms to EN 61000-6-2/EN 61000-6-4

Compliance and Certifications

Approvals and Markings CE, UL, ATEX, DNV GL
Ex Marking II 3 G Ex nA IIC T4 Gc

Installation Guidelines

  1. Power Off: Disconnect and lock out all power sources feeding the Bus Terminal system and field devices before installation or removal.
  2. Mounting: Snap the terminal onto a standard 35 mm DIN rail (conforming to EN 60715). Ensure the double slot-and-key connection is securely aligned with adjacent terminals.
  3. Plugging Wiring Level: Insert the wired connector block into the terminal housing until it clicks into place.
  4. Wiring: Connect the signal wires according to standard single-ended voltage measurement layouts using a screwdriver to actuate the spring-clamp terminals. Strip wire insulation back 9 to 10 mm.
  5. System Verification: Ensure correct installation of shield connections where necessary to protect sensitive analog signals from external electromagnetic interference.

Replacement Recommendations

When replacing an existing BECKHOFF KS3404, the pluggable wiring level allows maintenance personnel to swap the physical electronics block without disconnecting individual wires from the spring clamps. Ensure that the bus segment is fully de-energized before removing the connector block or pulling the terminal off the DIN rail. Verify that the successor or replacement model matches the configuration requirements in the TwinCAT system manager.

Loading product navigation…
Key Features:

What is the primary function of the BECKHOFF KS3404?

The BECKHOFF KS3404 is a 4-channel analog input Bus Terminal designed to measure analog standard signals in the -10 V to +10 V range, transmitting them with a 12-bit resolution to the higher-level controller via the K-bus.

What is the difference between the KL3404 and the KS3404 terminals?

The BECKHOFF KS3404 features a pluggable wiring level, allowing the entire terminal block's wiring harness to be plugged or unplugged as a single assembly, whereas the standard KL3404 uses fixed wiring clamps directly integrated into the terminal housing.

Does the BECKHOFF KS3404 require power contacts for its operation?

No, the BECKHOFF KS3404 does not draw current from the power contacts; its internal electronic circuitry is powered exclusively via the K-bus, drawing a typical current of 100 mA.

What level of electrical isolation does the BECKHOFF KS3404 provide?

The BECKHOFF KS3404 provides 500 V of electrical isolation between the K-bus communication lines and the field-side analog signal lines.

What is the measurement resolution of the BECKHOFF KS3404?

The BECKHOFF KS3404 provides a 12-bit resolution for the full -10 V to +10 V range, which adjusts to an 11-bit resolution when utilizing a 0 to 10 V range.

Global Express Shipping

  • Standard Delivery: 4-6 Business Days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries, including rapid delivery to Saudi Arabia and UAE.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our professional technical warranty.

Orders are processed and delivered Monday-Friday (excluding public holidays).


For full eligibility, restocking fees, and international return details, please view our official Refund & Return Policy .

TECHNICAL SPECIFICATIONS

Country of origin
Germany

Technical knowledge

1756-L73 Firmware Upgrade Guide: v19 vs v21/v31 Decision

Replacing a 1756-L73 does not automatically mean upgrading its firmware. This guide compares v19.013, v21.011 and v31.011, focusing on project compatibility, HMI communications, legacy networks and...

Implementing 3-Switch XOR Ladder Logic with Internal Bit

Implement a 3-SPST switch XOR light circuit in LogixPro or RSLogix 500 using an internal relay bit. Includes truth tables, boolean equations, and verified.

Building a Modbus RTU Network with CompactLogix and DeltaV

Integrate Allen-Bradley CompactLogix, Caterpillar ATS, and generators into DeltaV DCS over Modbus RTU. Covers ProSoft MVI69-MCM, Miille DIN266 gateways.

ONS Instruction Not Energizing OTE in Studio 5000 Ladder Logic

ONS instruction fires but the OTE coil never latches in Studio 5000 because the one-shot is only true for one scan. Use OTL/OTU or seal-in logic instead.

Kinetix 5500 EtherNet/IP Network Switch Requirements and Topology

Configure Allen-Bradley Kinetix 5500 servo drives on EtherNet/IP. Covers CIP Sync, IEEE 1588 V2 timing, Stratix selection, DLR topology, and HMI.

Moving Average Filtering in DCS and PLC Analog Control

A moving-average filter is the sliding-window smoother most instrument engineers drop into DCS and PLC analog paths. Here is how the window works, how N and sample time set lag, and when a...