Bently Nevada

Bently Nevada 125840-02 3500/15 Low Voltage AC Power Input Module

SKU 125840-02

In stock
  • 12-month warranty
  • Free returns within 30 days
  • Manufacturer: Bently Nevada

  • Product No.: 125840-02

  • Country of origin:United States

  • Product Type: Low Voltage AC Power Input Module

  • Barcode: 8537101190

  • Payment: T/T, Western Union

  • Weight: 340g

  • Dimensions: 25.4 mm x 120.7 mm x 114.3 mm (W x H x D)

  • Shipping port: Xiamen

  • Warranty: 12 months

Description

The Bently Nevada 125840-02 is a Low Voltage AC Power Input Module designed for accepting external low-voltage AC line power and interfacing directly with the 3500/15 AC Power Supply module in the 3500 Machinery Protection System. Operating as a half-height module positioned in the special rear slot directly behind its associated front-installed power supply, the 125840-02 receives line voltage, routes it through an onboard replacement fuse, and routes the conditioned power to the 3500 rack system. It supports a nominal 110 Vac input with an operating range of 85 to 132 Vac rms (and 85 to 125 Vac rms for PIM revisions prior to Rev. R paired with AC Power Supply Modules prior to Rev. M) to power a full rack without requiring a minimum rack load.

Features

  • Special half-height rear module mounting positioned directly behind the associated front power supply module
  • Onboard fuse protection utilizing part number 01720025 replacement fuse
  • Accepts a nominal input voltage of 110 Vac over an operating range of 85 to 132 Vac rms
  • Accepts input line frequency from 47 to 63 Hz
  • Supports primary or redundant power configuration in designated left-side rack slots

Applications

  • Power input interface for Bently Nevada 3500 Series Machinery Protection Systems
  • Low-voltage AC main power connection for 3500/15 AC Power Supply Modules
  • Rotating machinery and turbomachinery condition monitoring installations requiring 110 Vac field power

Ordering Information

Part Number Description
125840-02 Low Voltage AC Power Input Module
127610-01 AC Power Supply Module
01720025 Replacement Fuse (for both AC Power Input Module and High Voltage DC Power Input Modules)

Technical Specifications

Parameter Specification
Manufacturer Bently Nevada / GE Measurement & Control
Part Number 125840-02
Module Type Legacy Low Voltage AC Power Input Module (PIM)
Nominal Input Voltage 110 Vac nominal
Input Voltage Range 85 to 132 Vac rms (120 to 188 Vac pk)
Legacy Voltage Range 85 to 125 Vac rms (for PIM prior to Rev. R / Power Supply prior to Rev. M)
Input Frequency 47 to 63 Hz
Full Rack Current Draw 4.5 A rms (maximum)
Out of Range Protection Under-voltage does not harm the PIM; Over-voltage causes the fuse to open
Replacement Fuse Part Number 01720025
Dimensions (H x W x D) 120.7 mm x 25.4 mm x 114.3 mm (4.75 in x 1.0 in x 4.5 in)
Weight 0.34 kg (0.75 lb)
Operating Temperature -30 degC to +65 degC (-22 degF to +150 degF)
Storage Temperature -40 degC to +85 degC (-40 degF to +185 degF)
Humidity 95%, non-condensing

Connections/Interfaces

Terminal Block Identifier Function
LN1 Line Input Connection 1
LN2 / NEUT Line Input Connection 2 / Neutral
GND Protective Earth Ground Terminal

Installation Guidelines

  • Install the module in the special half-height rear slot located directly behind the associated front 3500/15 power supply module.
  • Secure input field wiring to the designated LN1, LN2/NEUT, and GND screw terminals on the rear terminal strip.
  • Verify that field voltage is de-energized prior to installing or removing the input wiring and terminal assembly.
  • Ensure proper insertion of the specified 01720025 replacement fuse into the PIM fuse holder.

Compliance and Certifications

  • EMC Standards: EN 61000-6-2 (Immunity for Industrial Environments), EN 61000-6-4 (Emissions for Industrial Environments)
  • EMC Directive: European Community Directive 2014/30/EU
  • Electrical Safety Standard: EN 61010-1
  • Low Voltage Directive: European Community Directive 2014/35/EU
  • CSA / NRTL/C (Approval Option 01): Class I, Division 2, Groups A, B, C, D; Class I, Zone 2; Ex nC [L] IIC T4 Gc / AEx nC IIC T4 Gc (T4 @ Ta = -20 degC to +65 degC)
  • ATEX / IECEx (Approval Option 02): II 3 G, Ex nA nC ic IIC T4 Gc (T4 @ Ta = -20 degC to +65 degC)

FAQ

Which physical slot position does the power input module occupy?

The module installs in the half-height rear slot located directly behind the associated 3500/15 front power supply module.

What is the operating AC voltage range for the module?

The module accepts an operating input range of 85 to 132 Vac rms at 47 to 63 Hz.

What happens to the module during an over-voltage event?

An over-voltage condition causes the onboard power input module fuse to open, protecting system components.

View all FAQs →

Product Documentation

Technical Datasheet (PDF) Complete specifications and technical drawings.

Technical Datasheet

Bently Nevada 125840-02 3500/15 Low Voltage AC Power Input Module

Quantity
Shipping & Returns

Global Express Shipping

  • Standard Delivery: 4–6 business days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our technical warranty.
Reviews
1 of 3
Only 5 item(s) left in stock
Quantity
View full details

Global Express Shipping

  • Standard Delivery: 4-6 Business Days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries, including rapid delivery to Saudi Arabia and UAE.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our professional technical warranty.

Orders are processed and delivered Monday-Friday (excluding public holidays).


For full eligibility, restocking fees, and international return details, please view our official Refund & Return Policy .

TECHNICAL SPECIFICATIONS

Color pattern
Silver
Country of origin
United States
Power source
AC-powered

Technical knowledge

First TwinCAT PLC Project on a Beckhoff IPC

Build and verify a first TwinCAT PLC project on a Beckhoff IPC. This checklist covers target selection, EtherCAT discovery, I/O mapping, safe activation, restart tests, and commissioning records.

Commissioning OPC UA in KEPServerEX: A Field Checklist

A practical commissioning sequence for KEPServerEX OPC UA connections: define data ownership, test tags locally, configure endpoint and certificate trust, limit access, then verify failure recovery...

Set a PLC Commissioning Laptop IP Without Losing Access

Commissioning an Ethernet-connected PLC often starts with the laptop, not the controller. Learn how to record existing settings, choose a temporary address, test connectivity, and restore the plant...

Designing Automation for Combustible Dust Hazards

Combustible dust controls require more than alarms. Learn how to map dust generation, select instrumentation, design interlocks, handle failed feedback, test safe states, and maintain the full...

Hairpin Stators: Benefits, Limits, and Inspection

Hairpin windings raise slot fill and support compact traction motors, but conductor geometry, AC losses, insulation damage, weld quality, and cooling determine whether the design meets its targets.

Using Ansible for Controlled SCADA Server Changes

Use Ansible to standardize SCADA server changes without expanding OT risk. This guide covers inventories, idempotent playbooks, staged testing, credentials, logging, and practical rollback controls.