Bently Nevada

Bently Nevada 133819-02 3500/61 RTD/TC Non-Isolated I/O Module

SKU 133819-02

In stock
  • 12-month warranty
  • Free returns within 30 days
  • Manufacturer: Bently Nevada

  • Product No.: 133819-02

  • Country of origin:United States

  • Product Type: RTD/TC Non-Isolated I/O Module

  • Barcode: 8537101190

  • Payment: T/T, Western Union

  • Weight: 450g

  • Dimensions: 241.3 mm x 24.4 mm x 99.1 mm

  • Shipping port: Xiamen

  • Warranty: 12 months

Product Overview

The Bently Nevada 133819-02 is a specialized RTD/TC Non-Isolated I/O Module designed for the 3500/61 Temperature Monitor. This module provides the physical interface for six channels of temperature monitoring, supporting both Resistance Temperature Detectors (RTD) and Thermocouples (TC). The 133819-02 features Internal Terminations, allowing field wiring to connect directly to the terminal blocks on the I/O module itself. This non-isolated version offers maximum flexibility, permitting users to configure the module for TC, RTD, or a mixture of both sensor types across its six channels.

Functional Intelligence & Recorder Outputs

As a 3500/61 series component, this I/O module includes dedicated recorder outputs for each of its six channels. It provides a +4 to +20 mA signal proportional to the monitor's full-scale range, enabling seamless integration with external control systems, DCS, or chart recorders for data logging. The module's architecture is fault-tolerant; monitor operation remains unaffected by short circuits on the recorder outputs, ensuring that the primary machinery protection functions remain active.

Technical Specifications

Attribute Specification Details
Part Number 133819-02
Monitor Compatibility Bently Nevada 3500/61
Input Channels 6 (Individually programmable for RTD or TC)
Termination Type Internal Terminations (On-module)
Isolation Non-Isolated
RTD Current Source 925 ± 15 μA @ 25 °C
Recorder Output +4 to +20 mA (Load: 0 to 600 Ω)
Accuracy (Internal) ± 3 °C @ 25 °C (± 5.4 °F @ 77 °F)
Operating Temp -30 °C to +65 °C (-22 °F to +150 °F)
Weight 0.45 kg (1.0 lb)
Dimensions (HxWxD) 241.3 mm x 24.4 mm x 99.1 mm

Technical FAQs

What is the main difference between the 3500/60 and 3500/61 modules?Both modules provide identical six-channel temperature monitoring functionality. However, the 3500/61 (which uses the 133819-02 I/O) includes 4-20 mA recorder outputs for each channel, whereas the 3500/60 does not provide these analog outputs.

Can I mix different sensor types on a single 133819-02 module?Yes. Unlike the isolated versions, this non-isolated I/O module can be configured via the 3500 Rack Configuration Software to accept any combination of TC and RTD inputs across its six channels.

How does the module handle RTD wiring?The module provides a specialized current source of 925 μA. It is designed to support 3-wire RTDs (using two current supplies for lead-wire compensation) and 4-wire RTDs (using a single supply), ensuring accurate temperature measurement across various transducer types.


Field Engineering & Installation Guide

  • Internal Termination Management: The 133819-02 utilizes internal terminal blocks. Ensure that field wiring is properly labeled and securely fastened to prevent intermittent signals, which could trigger "Bypass" or "Error" status LEDs on the front panel of the monitor.

  • Environmental Considerations: The module is rated for an operating temperature range of -30 °C to +65 °C. For installations in extreme environments, ensure the 3500 rack has adequate ventilation to maintain these limits and prevent accuracy drift.

  • TMR Configuration: When used in Triple Modular Redundant (TMR) applications, three temperature monitors must be installed in adjacent groups. The system employs two types of voting to prevent single-point failures from causing false trips in critical machinery.

Engineering Advantages

The Bently Nevada 133819-02 provides a cost-effective, high-density solution for machinery temperature protection. By combining TC and RTD support into a single module with internal terminations, it reduces cabinet space and simplifies wiring complexity. For B2B procurement, choosing the original 133819-02 ensures full compatibility with the 3500 Monitoring System, maintaining the high accuracy and ruggedness required for protecting turbines, compressors, and large industrial motors.

Product Documentation

Technical Datasheet (PDF) Complete specifications and technical drawings.

Technical Datasheet

Bently Nevada 133819-02 3500/61 RTD/TC Non-Isolated I/O Module

Quantity
Shipping & Returns

Global Express Shipping

  • Standard Delivery: 4–6 business days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our technical warranty.
Reviews
1 of 3
Only 9 item(s) left in stock
Quantity
View full details

Global Express Shipping

  • Standard Delivery: 4-6 Business Days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries, including rapid delivery to Saudi Arabia and UAE.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our professional technical warranty.

Orders are processed and delivered Monday-Friday (excluding public holidays).


For full eligibility, restocking fees, and international return details, please view our official Refund & Return Policy .

TECHNICAL SPECIFICATIONS

Color pattern
Greyish White Silver
Country of origin
United States

Technical knowledge

Derivative Action in PID Control Without Noise Problems

Learn what derivative action contributes to a PID loop, why it can amplify measurement noise and setpoint changes, and how filtering, sampling, and staged tests make D tuning safer.

Designing Industrial Networks That Stay Troubleshootable

A practical guide to segmenting, documenting, and testing industrial Ethernet networks so plant teams can isolate faults quickly, control change, and expand without creating fragile dependencies.

Commissioning IO-Link From Master Ports to IODD Data

Commission IO-Link systematically from master addressing and port modes through IODD selection, PLC byte mapping, parameter backups, device validation, and failure-injection tests.

PowerFlex Dynamic Braking Resistor Design and Testing

A practical PowerFlex braking guide covering regenerative energy, resistor resistance and duty cycle, thermal protection, model-specific parameters, and measured commissioning tests.

Engineering Industrial Joystick Controls for Safe Motion

An industrial joystick is only the first element in a safe motion command chain. This guide covers sensing choices, wiring, signal validation, PLC logic, restart behavior, and commissioning for...

Seeing PID Behavior Before Tuning the Loop

PID tuning becomes safer when engineers can see how proportional, integral, and derivative actions reshape error, output, and response over time. This guide turns live trends into a disciplined...