Dimensions:
24.4 mm x 241.3 mm x 99.1 mm (W x H x D)
Shipping port:
Xiamen
Warranty:
12 months
Description
The Bently Nevada 135813-01 is a Display Interface I/O Module designed for local or remote visual indication of all 3500 Machinery Protection System information residing in the rack. The 135813-01 interacts with the 3500 backplane network to collect current values, System Event Lists, Alarm Event Lists, and status data across all channel, monitor, relay, Keyphasor, or tachometer modules. The module provides hardware interface output connectivity for communication with the 3500/93 Display Unit via an RS422 physical layer supporting Bently Nevada proprietary protocol and Modbus protocol.
Features
Occupies 1 full-height rear slot in the 3500 rack
Features a dedicated Display Communications Port for RS422 connection to the 3500/93 Display Unit
Collects machinery protection data and event status via a high-speed internal backplane network
Enables rear cable routing option for connecting the display unit to the 3500 Machinery Protection System
Applications
Local or remote display interface connection for 3500 Machinery Protection Systems
Industrial rotating machinery monitoring and visual indication
Ordering Information
Part Number
Description
135813-01
3500/93 Display Interface I/O Module
135799-01
3500/93 Display Interface Module
135799-02
3500/93 Display Interface Module (use with A05 thru A08 options)
135785-01
3500/93 Display Unit, non back-lighted
135785-02
3500/93 Display Unit, back-lighted
Technical Specifications
Parameter
Specification
Manufacturer
Bently Nevada
Part Number
135813-01
Module Type
Display Interface I/O Module
Dimensions (H x W x D)
241.3 mm x 24.4 mm x 99.1 mm (9.50 in x 0.96 in x 3.90 in)
Weight
0.38 kg (0.84 lb)
Rack Space Requirements
1 full-height rear slot
Operating Temperature
-30 degC to +65 degC (-22 degF to +150 degF)
Storage Temperature
-40 degC to +85 degC (-40 degF to +185 degF)
Humidity
95%, noncondensing
Communication Hardware
RS422 Interface
Protocols
GE Bently Nevada proprietary protocol, Modbus protocol (based on AEG PI-MBUS-300 Rev. E Reference Manual)
Channel Update Rate
1 second, typical
Connections/Interfaces
Connector / Port
Function
Display Communications Port
RS422 interface for connecting to the 3500/93 Display Unit
Installation Guidelines
Installs in 1 full-height rear slot of the 3500 Machinery Protection System rack.
Serves as the rear wiring interface point connecting to the front-mounted Display Interface Module (DIM) via the rack backplane.
Allows display connection routing from the rear of the rack when the display is not face-mounted.
Compliance and Certifications
Standard / Directive
Detail
EMC Standards
EN 61000-6-2 Immunity for Industrial Environments, EN 55011/CISPR 11 ISM Equipment, EN 61000-6-4 Emissions for Industrial Environments
European Community Directives
EMC Directive 2004/108/EC
Electrical Safety
EN 61010-1, 2006/95/EC Low Voltage Directive
CSA/NRTL/C
Option (01): AEx nA IIC: Class I, Zone 2, Div 2 Groups A, B, C, D; T4 @ Ta = -30 degC to +65 degC (-22 degF to +150 degF)
ATEX
Option (02): II 3/ (1) G Ex nC[nL Gc] IIC T4 Gc; T4 @ Ta = -20 degC to +65 degC (-4 degF to +150 degF)
Brazil
Option (02): BR-Ex nC [nL] IIC T4; T4 @ Ta = -20 degC to +65 degC (-4 degF to +150 degF)
South Africa
Option (02): Ex nCAL [ia] IIC T4, Ex nCAL [L] IIC T4; T4 @ Ta = -20 degC to +65 degC (-4 degF to +150 degF)
FAQ
Which slot location does the I/O module occupy in the rack?
The module installs in 1 full-height rear slot of the 3500 Machinery Protection System rack.
What physical interface is used to connect to the display unit?
The device provides an RS422 interface port for direct communication with the 3500/93 Display Unit.
Which protocols are supported across the display communication link?
The module supports GE Bently Nevada proprietary protocol and Modbus protocol based on AEG PI-MBUS-300.
What is the operating temperature range for the I/O module?
The module operates in ambient temperatures from -30 degC to +65 degC (-22 degF to +150 degF).
A practical commissioning sequence for KEPServerEX OPC UA connections: define data ownership, test tags locally, configure endpoint and certificate trust, limit access, then verify failure recovery...
Commissioning an Ethernet-connected PLC often starts with the laptop, not the controller. Learn how to record existing settings, choose a temporary address, test connectivity, and restore the plant...
Combustible dust controls require more than alarms. Learn how to map dust generation, select instrumentation, design interlocks, handle failed feedback, test safe states, and maintain the full...
Hairpin windings raise slot fill and support compact traction motors, but conductor geometry, AC losses, insulation damage, weld quality, and cooling determine whether the design meets its targets.
Use Ansible to standardize SCADA server changes without expanding OT risk. This guide covers inventories, idempotent playbooks, staged testing, credentials, logging, and practical rollback controls.
A VPN encrypts the path to an industrial network, but secure remote PLC work also needs identity controls, segmented access, change approval, logging, safe operating boundaries, and tested recovery...
Choosing a selection results in a full page refresh.