Derivative Action in PID Control Without Noise Problems
Learn what derivative action contributes to a PID loop, why it can amplify measurement noise and setpoint changes, and how filtering, sampling, and staged tests make D tuning safer.
Manufacturer: Bently Nevada
Product No.: 3500/61 136711-02
Country of origin:United States
Product Type: Temperature Monitor I/O Module
Barcode: 8537101190
Payment: T/T, Western Union
Weight: 940g
Dimensions: 2.3cm x 18.5cm x 24.1cm
Shipping port: Xiamen
Warranty: 12 months
The Bently Nevada 136711-02 is a specialized RTD/TC I/O Module with Internal Barriers and Internal Terminations developed for the 3500/61 16-Channel Temperature Monitor within the 3500 Series Machinery Protection System. This hardware component serves as the physical interface layer that collects multi-channel temperature signals from field-located transducers. This specific non-isolated variant is engineered with integrated safety barriers, allowing users to configure the termination paths to accept either thermocouple (TC) or resistance temperature detector (RTD) inputs, as well as a flexible combination of both sensor categories simultaneously within the same rack subsystem.
Field programming and configuration of channel types are handled through the 3500 Rack Configuration Software, removing any requirements for physical hardware modifications or field calibration procedures. The module conditions the raw millivolt signals from thermocouples and resistance variances from 3-wire or 4-wire RTDs, feeding structured digital temperature values directly into the main front processor card via the internal backplane bus. Its onboard intrinsic safety design provides a high degree of integration by combining terminal blocks and hazardous area containment barriers into a single space-saving footprint, making the 3500/61 subsystem ideal for multi-point thermal surveillance of bearings, stator windings, and exhaust paths on heavy rotating assets.
| Parameter / Category | Specification Details |
|---|---|
| Electrical & Power | |
| Manufacturer | Bently Nevada |
| Country of Origin | USA |
| Module Subtype | Non-Isolated with Internal Safety Barriers |
| RTD Current Source Value | 925 +/- 15 uA at 25 degC per transducer (1 supply for 4-wire RTD, 2 supplies for 3-wire RTD) |
| Transducer & Sensor Inputs | |
| Thermocouple (TC) Capability | Type E, Type J, Type K, Type T |
| Thermocouple Temperature Ranges |
Type E: -100 degC to +1000 degC (-148 degF to +1832 degF)
Type J: -18 degC to +760 degC (+0 degF to +1400 degF)
Type K: -18 degC to +1370 degC (+0 degF to +2498 degF)
Type T: -160 degC to +400 degC (-256 degF to +752 degF) |
| Resistance Temperature Detector (RTD) | 100 Ohm platinum (alpha = 0.00385), 100 Ohm platinum (alpha = 0.00392), 120 Ohm nickel, 10 Ohm copper |
| RTD Measurement Ranges |
100 Ohm platinum (0.00385): -200 degC to +850 degC (-328 degF to +1562 degF)
100 Ohm platinum (0.00392): -200 degC to +700 degC (-328 degF to +1292 degF)
120 Ohm nickel: -80 degC to +260 degC (-112 degF to +500 degF)
10 Ohm copper: -100 degC to +260 degC (-148 degF to +500 degF) |
| Ranges with External Barriers |
100 Ohm platinum (0.00385): -50 degC to +850 degC (-122 degF to +1562 degF)
100 Ohm platinum (0.00392): -50 degC to +260 degC (-122 degF to +1292 degF)
120 Ohm nickel: -50 degC to +260 degC (-122 degF to +500 degF)
10 Ohm copper: -50 degC to +260 degC (-122 degF to +500 degF) |
| Signal Conditioning & Accuracy | |
| Measurement Resolution | 1 degC or 1 degF (except for 10 Ohm Copper RTDs) |
| Non-Isolated External Termination Accuracy |
Bulkhead Rack: +/-3 degC at 25 degC (+/-5.4 degF at 77 degF)
Standard Rack: +/-1 degC at 25 degC (+/-1.8 degF at 77 degF) |
| Isolated Internal Termination Accuracy |
Bulkhead Rack: +/-2 degC at 25 degC (+/-3.6 degF at 77 degF) / +/-3 degC at 25 degC (+/-5.4 degF at 77 degF)
Standard Rack: +/-3 degC at 25 degC (+/-5.4 degF at 77 degF) |
| Calibration | No field calibration required; specified at +25 degC (+77 degF) |
| Environmental Limits | |
| Operating Temperature | 0 degC to +65 degC (32 degF to +150 degF) when used with Internal Barrier modules |
| Storage Temperature | -40 degC to +85 degC (-40 degF to +185 degF) |
| Mechanical Dimensions & Weight | |
| I/O Module Dimensions (H x W x D) | 241.3 mm x 24.4 mm x 163.1 mm (9.50 in x 0.96 in x 6.42 in) |
| Module Weight | 0.46 kg (1.01 lb) |
| Rack Position Requirements | Consumes 1 full-height rear slot directly behind the main monitor processor card |
| Connector Pin / Terminal Block | Function Assignment |
|---|---|
| Internal Barrier Screw Terminals | Direct physical land connection for raw multi-wire RTD leads and TC field extensions |
| Internal Backplane Bus Plug | Multi-pin interconnect matrix delivering conditioned sensor data to the 3500 rack bus |
What is the function of the 136711-02 component?
It acts as the rear terminal and intrinsic safety interface module that routes field RTD and thermocouple signals into a 3500/61 monitor slot.
What does the designation non-isolated mean for this module?
It indicates that the channels share a common ground reference point, although they remain protected via built-in internal safety barriers.
Can I mix thermocouples and RTDs on the same I/O card?
Yes, the non-isolated channel paths can be customized individually via software to accept a mixed combination of TCs and RTDs.
What specific type of RTD is recommended for standard engineering installations?
Platinum RTDs featuring an alpha value of 0.00385 are the industrial standard and are highly recommended for optimal precision.
Is manual field calibration required after replacing this hardware?
No manual field calibration is needed because all channel parameter scaling is managed automatically through system configuration software.
What constant current value is provided for RTD sensors by this module?
The integrated current source network delivers 925 +/- 15 uA at an environmental reference of 25 degC per transducer pathway.
How many internal current supplies are engaged when a 4-wire RTD is connected?
The module configuration activates a single current supply line for a 4-wire RTD circuit and two separate supplies for a 3-wire RTD circuit.
What is the defined operating temperature limitation for this module version?
The module is specified to perform reliably in a continuous ambient temperature environment ranging from 0 degC to +65 degC.
What are the exact physical dimensions of this rear-mount component?
The card measures 241.3 mm in height, 24.4 mm in width, and 163.1 mm in depth.
Does this component contain the primary digital processor card?
No, this part number represents the rear-insert I/O termination assembly with built-in barriers; the front processor module is supplied separately.
Global Express Shipping
Returns & Warranty



Global Express Shipping
Returns & Warranty
Orders are processed and delivered Monday-Friday (excluding public holidays).
For full eligibility, restocking fees, and international return details, please view our official Refund & Return Policy .
| Color pattern |
Greyish White
Silver
|
| Country of origin |
United States
|