The Bently Nevada 169459-01 is a vibration monitoring I/O module designed for aeroderivative gas turbine vibration monitoring systems within the 3500 Machinery Protection System. Installed in a full-height rear slot of the 3500 rack, it serves as the rear interface card for the 3500/44M Aeroderivative GT Vibration Monitor. The module processes field signals from Proximitor sensors, Velomitors, and accelerometers with a high input impedance. Onboard internal termination headers allow direct wiring connection, accepting contact inputs for machine mode switching to alter alert and danger alarm parameter sets, while sending current outputs through 4 to 20 mA recorder channels.
Features
Integrates directly into a single full-height rear slot of the 3500 system rack
Features internal termination headers with Euro-Style or Push-in-Spring connector options for direct transducer and system wiring
Interfaces with Proximitor sensors, Velomitor sensors, and accelerometers for aeroderivative gas turbine monitoring
Supports multimode machine operation by accepting external mode switching contacts to toggle between up to eight alarm parameter sets
Provides dedicated +4 to +20 mA recorder output channels proportional to overall monitor full-scale values
Applications
Aeroderivative gas turbine machinery protection and vibration monitoring
Dynamic signal processing for Proximitor, Velomitor, and accelerometer transducer loops
Multi-mode machine operation tracking with automated alarm setpoint switching
Ordering Information
Part Number / Option
Description
3500/44-07-BB
Multimode Prox/Velom I/O Module with Internal Terminations
169459-01
Multimode Prox/Velom I/O Module with Internal Terminations (Spare Part)
00580434
Euro Style connector header, 8 pin, Green (For I/O modules with internal terminations)
00580432
Euro Style connector header, 10 pin, Green (For I/O modules with internal terminations)
00561941
Prox/Velom and Multimode Prox/Velom I/O Module ten-pin connector shunt
166M2389
Connector Header, Push-in-Spring Type (Alternative for PN 00580434)
166M2388
Connector Header, Push-in-Spring Type (Alternative for PN 00580432)
241.3 mm x 24.4 mm x 99.1 mm (9.50 in x 0.96 in x 3.90 in)
Mechanical
Weight
0.45 kg (1.0 lb)
Rack Requirement
Space Requirement
1 full-height rear slot
Installation Guidelines
Rack Insertion: Install the module strictly in a full-height rear slot directly behind the associated 3500/44M main monitor module.
Field Wiring: Connect field transducer, recorder, and mode control wiring directly to the internal termination blocks using either Euro-Style or Push-in-Spring connector headers.
Jumper Configuration: Configure module jumpers according to system channel setup prior to powering up the rack.
Compliance and Certifications
Standard Type
Designation / Specification
FCC
Complies with part 15 of FCC Rules
EMC
European Community Directive 2014/30/EU; EN 61000-6-2, EN 61000-6-4
Electrical Safety
European Community Directive 2014/35/EU; EN 61010-1
RoHS
European Community Directive 2011/65/EU; China RoHS EFUP 15 years per SJ/T 11364-2024
Maritime
DNV GL rules for classification; ABS Rules for Condition of Classification Part 1
Hazardous Area (cNRTLus - No Barriers)
Class I, Zone 2: AEx/Ex nA nC ic IIC T4 Gc; Class I, Zone 2: AEx/Ex ec nC ic IIC T4 Gc; Class I, Division 2, Groups A, B, C, D; T4 @ Ta = -20 degC to +65 degC
Hazardous Area (cNRTLus - With Barriers)
Class I, Zone 2: AEx/Ex nA nC ic [ia Ga] IIC T4 Gc; Class I, Zone 2: AEx/Ex ec nC ic [ia Ga] IIC T4 Gc; Class I, Division 2, Groups A, B, C, D (W/ IS Output for Division 1); T4 @ Ta = -20 degC to +65 degC
Hazardous Area (ATEX/IECEx - No Barriers)
II 3 G Ex nA nC ic IIC T4 Gc; Ex ec nC ic IIC T4 Gc; T4 @ Ta = -20 degC to +65 degC
Hazardous Area (ATEX/IECEx - With Barriers)
II 3(1) G Ex nA nC ic [ia Ga] IIC T4 Gc; Ex ec nC ic [ia Ga] IIC T4 Gc; T4 @ Ta = -20 degC to +65 degC
FAQ
Which slot does the rear I/O module occupy in the rack?
The module installs in one full-height rear slot directly behind the 3500/44M main monitor card.
What is the update rate for the onboard 4 to 20 mA recorder outputs?
The integrated current recorder channels provide an update rate of 100 ms or less.
What input impedance does the board present to connected sensors?
The card presents an input impedance of 10 kOhm for Proximitor and acceleration sensors, and 3.5 MOhm for Velomitors.
A practical commissioning sequence for KEPServerEX OPC UA connections: define data ownership, test tags locally, configure endpoint and certificate trust, limit access, then verify failure recovery...
Commissioning an Ethernet-connected PLC often starts with the laptop, not the controller. Learn how to record existing settings, choose a temporary address, test connectivity, and restore the plant...
Combustible dust controls require more than alarms. Learn how to map dust generation, select instrumentation, design interlocks, handle failed feedback, test safe states, and maintain the full...
Hairpin windings raise slot fill and support compact traction motors, but conductor geometry, AC losses, insulation damage, weld quality, and cooling determine whether the design meets its targets.
Use Ansible to standardize SCADA server changes without expanding OT risk. This guide covers inventories, idempotent playbooks, staged testing, credentials, logging, and practical rollback controls.
A VPN encrypts the path to an industrial network, but secure remote PLC work also needs identity controls, segmented access, change approval, logging, safe operating boundaries, and tested recovery...
Choosing a selection results in a full page refresh.