Bently Nevada

Bently Nevada 170180-02-00 FieldMonitor External Transducer I/O Module

SKU 170180-02-00

In stock
  • 12-month warranty
  • Free returns within 30 days
  • Manufacturer: Bently Nevada

  • Product No.: 170180-02-00

  • Country of origin:United States

  • Product Type: I/O Module

  • Barcode: 8537101190

  • Payment: T/T, Western Union

  • Weight: 277g

  • Dimensions: 45 mm x 120 mm x 100 mm

  • Shipping port: Xiamen

  • Warranty: 12 months

Description

The Bently Nevada 170180-02-00 is an external transducer I/O module designed for use with the FieldMonitor machinery protection system. The 170180-02-00 connects 2-wire velocity transducers to their respective 2-channel monitoring module within the FieldMonitor assembly. Occupying a single slot in a FieldMonitor terminal base, it provides signal routing and interface conditioning for two independent 2-wire velocity transducer inputs. This specific configuration features a dual velocity I/O module setup with Division 2 / Zone 2 hazardous area approval rating.

Features

  • Interfaces two independent 2-wire velocity transducer inputs to FieldMonitor monitoring modules
  • Occupies one slot in a FieldMonitor terminal base
  • Provides signal conditioning and routing for two transducer channels
  • Certified for Division 2 / Zone 2 hazardous areas

Applications

  • Machinery protection and condition monitoring for industrial rotating equipment
  • Vibration and velocity measurement integration for turbines, pumps, compressors, and motors
  • Signal expansion within Bently Nevada FieldMonitor terminal base systems

Ordering Information

Part Number Description
170180-02-00 FieldMonitor External Transducer I/O Module
02 Transducer Type: Dual Velocity I/O Module (Channel A: One 2-wire Velocity Transducer, Channel B: One 2-wire Velocity Transducer)
00 Approvals / Agency Option: Division 2/Zone 2

Technical Specifications

Parameter Category Specification Details
Manufacturer Bently Nevada
Part Number 170180-02-00
Signal Inputs Channel A: One 2-wire Velocity Transducer; Channel B: One 2-wire Velocity Transducer
Input Signal Voltage Range 0 to -Vt
Output Voltage Range 0 to -Vt
Frequency Response -5% at >25 kHz
Input Impedance 9.98 +/- 0.02 kOhm
Current Draw (Without Transducer) 2.0 mA maximum
Operating Temperature -34 degC to +85 degC (-30 degF to +185 degF)
Storage Temperature -40 degC to +85 degC (-40 degF to +185 degF)
Relative Humidity 100% condensing nonsubmerged from +7 degC to +85 degC (+45 degF to +185 degF) when connector is protected
Slot Requirement Occupies 1 slot in FieldMonitor terminal base
Weight 277 g (0.61 lb) typical

Installation Guidelines

  • Slot Placement: Insert the module into a dedicated slot within the FieldMonitor terminal base.
  • Transducer Wiring: Connect 2-wire velocity transducers to Channel A and Channel B terminals according to system wiring diagrams.
  • Environmental Protection: Ensure field connectors are properly mated and sealed to protect against humidity condensation.

Compliance and Certifications

  • Hazardous Area Approvals: Division 2 / Zone 2

FAQ

What sensor types can be connected to this I/O module?

This module is configured specifically to accept inputs from two 2-wire velocity transducers across Channel A and Channel B.

How many slots does the device occupy in the FieldMonitor system?

The module occupies a single slot in a FieldMonitor terminal base.

What is the operating temperature range for this module?

The operating temperature range is from -34 degC to +85 degC (-30 degF to +185 degF).

View all FAQs →

Quantity
Shipping & Returns

Global Express Shipping

  • Standard Delivery: 4–6 business days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our technical warranty.
Reviews
1 of 3
Only 7 item(s) left in stock
Quantity
View full details

Global Express Shipping

  • Standard Delivery: 4-6 Business Days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries, including rapid delivery to Saudi Arabia and UAE.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our professional technical warranty.

Orders are processed and delivered Monday-Friday (excluding public holidays).


For full eligibility, restocking fees, and international return details, please view our official Refund & Return Policy .

TECHNICAL SPECIFICATIONS

Color pattern
Black
Country of origin
United States

Technical knowledge

Engineering Logix Produced and Consumed Tags

A field-ready guide to Logix produced and consumed tags, covering data contracts, RPI selection, connection status, stale-data handling, commissioning and controller-to-controller troubleshooting.

Commissioning AS-Interface Networks Without Guesswork

A practical AS-Interface commissioning method covering topology, power and voltage-drop checks, addressing, PLC mapping, fault tests and maintenance records for reliable actuator-sensor networks.

Selecting Line Reactors and Output Filters for VFDs

Learn how line reactors, harmonic filters, output reactors, dV/dt filters, and sine filters address different VFD power-quality and motor-cable problems—and how to select them safely.

Light-On and Dark-On Photoelectric Sensor Logic

Learn how light-on and dark-on photoelectric sensor modes interact with through-beam, retroreflective, and diffuse sensing, PNP/NPN wiring, PLC logic, commissioning, and fault detection.

Designing H-Bridge Motor Drives Without Shoot-Through

A practical guide to H-bridge motor drives covering switching states, dead time, inductive current paths, PWM choices, protection, PCB layout, PLC interfacing, and staged commissioning tests.

Designing Mitsubishi FX PLC Sequences with STL and RET

Learn how Mitsubishi FX PLC STL and RET instructions structure conveyor and pneumatic sequences, with practical state design, transition logic, timeouts, diagnostics, and safe restart boundaries.