Bently Nevada

Bently Nevada 1900/65A-00-00-01-CN-00 1900/65A General Purpose Equipment Monitor

SKU 1900/65A-00-00-01-CN-00

In stock
  • 12-month warranty
  • Free returns within 30 days
  • Manufacturer: Bently Nevada
  • Product No.: 1900/65A-00-00-01-CN-00
  • Origin United States
  • Product Type: Vibration Monitoring Systems
  • Payment: T/T, Western Union
  • Weight: 0.32 kg
  • Dimensions: 320 mm x 250 mm x 190 mm
  • Shipping port: Xiamen
  • Warranty: 12 months

Tags

Quantity

Product Description

Description

To deliver continuous machinery protection in space-constrained panels, the Bently Nevada 1900/65A-00-00-01-CN-00 functions as a standalone, micro-processor-based vibration and temperature monitoring system. This industrial unit processes inputs from dynamic transducers—such as proximity probes, velocity sensors, and accelerometers—alongside thermal sensor inputs, providing real-time alarm and shutdown capabilities for critical auxiliary machinery. Engineered for remote and decentralized mounting, this headless variant operates without an integrated physical display, instead routing critical status and process data through onboard relays and dynamic buffered outputs.

Features

  • Four Dynamic Channels: Configurable to accept standard vibration, position, and speed transducers.
  • Two Static Temperature Channels: Direct support for RTD and Thermocouple sensors to assess thermal stress on bearings and casings.
  • DIN Rail Mounting (Option 01): Standardized 35mm DIN rail mounting interface for secure mechanical integration into local junction boxes.
  • Headless Operations (Option 00): Omits the physical display panel to prevent unauthorized field adjustments and save cabinet depth.
  • Wide Range DC Input (Option 00): Operates reliably on stable 18 to 36 Vdc industrial distribution loops.
  • Integrated Alarm Logic: Built-in configurable SPDT relays for direct hardware trip-loop wiring.

Applications

  • Electric Motors & Generators: Continuous casing and bearing vibration tracking with winding temperature cross-referencing.
  • Centrifugal & Lobe Blowers: Surge and mechanical imbalance detection in chemical processing environments.
  • Industrial Water Pumps: Localized protection arrays for high-flow cooling and distribution systems.
  • Cooling Tower Fans: Decentralized monitoring inside hazardous wet areas utilizing local protective enclosures.

Technical Specifications

Parameter Specification Value
Manufacturer Bently Nevada (Baker Hughes)
Model Code 1900/65A-00-00-01-CN-00
Power Input Option 18 to 36 Vdc (Option 00)
Local Display Option No Display (Option 00)
Mounting Configuration 35mm DIN Rail Mount (Option 01)
Agency Approvals CN / China Region-Specific Certification (Option CN)
Communications None Installed (Option 00)
Dynamic Signal Channels 4 channels (acceleration, velocity, or proximity)
Static Input Channels 2 channels (RTD/Thermocouple or static voltage inputs)
Onboard Relays 6 Programmable SPDT dry contacts
Operating Temperature -20 to +70 Celsius
Country of Origin United States (U.S.A.)
Shipping Weight (Calculated) 8.00 kg
Package Dimensions (Calculated) 320 mm x 250 mm x 190 mm

Connections and Interfaces

Terminal / Port Block Signal / Circuit Assignment
Power Input Terminals 24 Vdc (+) / Common (-) / Chassis Earth Ground
Dynamic Channels (1-4) Sensor Excitation Power, Signal Return, and Instrument Common
Static Channels (5-6) RTD Constant Current Source, Return, Shield, and Thermocouple Compensation
Relay Contact Blocks Normally Open (NO), Normally Closed (NC), and Common (COM) for dry loops
Buffered Outputs Dedicated raw waveform outputs for direct connection to diagnostic analyzers

Empirical Engineering Insights

Alternative Models & Compatibility

The 1900/65A series provides local machinery shutdown loop execution faster than a centralized 3500 rack system, acting as an autonomous safety interlock. Be aware that the display option '00' is physically incompatible with external display retrofits without full motherboard upgrades. When swapping units, verify the device's local internal configuration maps directly with the existing transducer scale factors via the configuration utility.

Application Pitfalls & Engineering Notes

Because this variant utilizes an 18 to 36 Vdc input range, supply electrical noise can couple into the high-frequency measurement circuits. Ensure you use an isolated, clean instrument-grade power supply to avoid false high-vibration alarms. Additionally, the blind front panel configuration means maintenance teams must use the programming interface to perform manual alarm resets if latching relays are selected in the software.

Commissioning & Wiring Tips

Ensure sensor cable shields are terminated at the monitor end only. Floating the shield at the transducer avoids forming localized ground loops that introduce mock signals at 50Hz or 60Hz. Verify proper installation orientation on the DIN rail to allow natural thermal convection across the aluminum heat dissipation casing.

Installation Guidelines

CRITICAL WARNING:

DE-ENERGIZE all input electrical lines before installing or removing terminal connections. Failure to follow safe isolating procedures can result in terminal damage, arc flash occurrences, or complete system component failure.

1

Snap the monitor onto the standard 35mm DIN rail, ensuring the locking clasp fully engages and stabilizes the housing.

2

Connect the dynamic vibration sensor wires to channels 1 through 4, referencing the specific transducer scale factor.

3

Perform shield grounding termination on the common bus rail immediately adjacent to the terminal block entry points.

4

Connect the 24 Vdc power input line, energize the source, and check status LEDs to confirm initial initialization behavior is nominal.

Shipping & Returns

Global Express Shipping

  • Standard Delivery: 4–6 business days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our technical warranty.
FAQ
How is this monitor configured without an integrated display?
This unit is parameterized using the dedicated programming software connected via its internal configuration interface. Once configured, it operates as a headless monitor, executing local shutdown functions based on preprogrammed logic.
Does this module supply power directly to connected vibration sensors?
Yes, it provides the required sensor excitation loop power for standard proximity probes, accelerometers, or Velomitors on each of its four dynamic input channels.
Can this specific unit be converted to include a local display later?
No, because the display option is determined by physical internal hardware during assembly. Upgrading to a display version requires changing to a different option configuration.
What is the function of the CN approval option on this device?
The CN option indicates the unit carries regulatory and electrical conformity approvals specified for industrial equipment deployments within regional Chinese jurisdictions.
Reviews

1900/65A-00-00-01-CN-00

Stock & lead time on request

Call
1 of 1

Bently Nevada 1900/65A-00-00-01-CN-00 1900/65A General Purpose Equipment Monitor

Only 8 item(s) left in stock
  • Manufacturer: Bently Nevada

  • Product No.: 1900/65A-00-00-01-CN-00

  • Country of origin:United States

  • Product Type: Vibration Monitoring Systems

  • Payment: T/T, Western Union

  • Weight: 320g

  • Dimensions: 320 mm x 250 mm x 190 mm

  • Shipping port: Xiamen

  • Warranty: 12 months

Quantity
View full details

Description

To deliver continuous machinery protection in space-constrained panels, the Bently Nevada 1900/65A-00-00-01-CN-00 functions as a standalone, micro-processor-based vibration and temperature monitoring system. This industrial unit processes inputs from dynamic transducers—such as proximity probes, velocity sensors, and accelerometers—alongside thermal sensor inputs, providing real-time alarm and shutdown capabilities for critical auxiliary machinery. Engineered for remote and decentralized mounting, this headless variant operates without an integrated physical display, instead routing critical status and process data through onboard relays and dynamic buffered outputs.

Features

  • Four Dynamic Channels: Configurable to accept standard vibration, position, and speed transducers.
  • Two Static Temperature Channels: Direct support for RTD and Thermocouple sensors to assess thermal stress on bearings and casings.
  • DIN Rail Mounting (Option 01): Standardized 35mm DIN rail mounting interface for secure mechanical integration into local junction boxes.
  • Headless Operations (Option 00): Omits the physical display panel to prevent unauthorized field adjustments and save cabinet depth.
  • Wide Range DC Input (Option 00): Operates reliably on stable 18 to 36 Vdc industrial distribution loops.
  • Integrated Alarm Logic: Built-in configurable SPDT relays for direct hardware trip-loop wiring.

Applications

  • Electric Motors & Generators: Continuous casing and bearing vibration tracking with winding temperature cross-referencing.
  • Centrifugal & Lobe Blowers: Surge and mechanical imbalance detection in chemical processing environments.
  • Industrial Water Pumps: Localized protection arrays for high-flow cooling and distribution systems.
  • Cooling Tower Fans: Decentralized monitoring inside hazardous wet areas utilizing local protective enclosures.

Technical Specifications

Parameter Specification Value
Manufacturer Bently Nevada (Baker Hughes)
Model Code 1900/65A-00-00-01-CN-00
Power Input Option 18 to 36 Vdc (Option 00)
Local Display Option No Display (Option 00)
Mounting Configuration 35mm DIN Rail Mount (Option 01)
Agency Approvals CN / China Region-Specific Certification (Option CN)
Communications None Installed (Option 00)
Dynamic Signal Channels 4 channels (acceleration, velocity, or proximity)
Static Input Channels 2 channels (RTD/Thermocouple or static voltage inputs)
Onboard Relays 6 Programmable SPDT dry contacts
Operating Temperature -20 to +70 Celsius
Country of Origin United States (U.S.A.)
Shipping Weight (Calculated) 8.00 kg
Package Dimensions (Calculated) 320 mm x 250 mm x 190 mm

Connections and Interfaces

Terminal / Port Block Signal / Circuit Assignment
Power Input Terminals 24 Vdc (+) / Common (-) / Chassis Earth Ground
Dynamic Channels (1-4) Sensor Excitation Power, Signal Return, and Instrument Common
Static Channels (5-6) RTD Constant Current Source, Return, Shield, and Thermocouple Compensation
Relay Contact Blocks Normally Open (NO), Normally Closed (NC), and Common (COM) for dry loops
Buffered Outputs Dedicated raw waveform outputs for direct connection to diagnostic analyzers

Empirical Engineering Insights

Alternative Models & Compatibility

The 1900/65A series provides local machinery shutdown loop execution faster than a centralized 3500 rack system, acting as an autonomous safety interlock. Be aware that the display option '00' is physically incompatible with external display retrofits without full motherboard upgrades. When swapping units, verify the device's local internal configuration maps directly with the existing transducer scale factors via the configuration utility.

Application Pitfalls & Engineering Notes

Because this variant utilizes an 18 to 36 Vdc input range, supply electrical noise can couple into the high-frequency measurement circuits. Ensure you use an isolated, clean instrument-grade power supply to avoid false high-vibration alarms. Additionally, the blind front panel configuration means maintenance teams must use the programming interface to perform manual alarm resets if latching relays are selected in the software.

Commissioning & Wiring Tips

Ensure sensor cable shields are terminated at the monitor end only. Floating the shield at the transducer avoids forming localized ground loops that introduce mock signals at 50Hz or 60Hz. Verify proper installation orientation on the DIN rail to allow natural thermal convection across the aluminum heat dissipation casing.

Installation Guidelines

CRITICAL WARNING:

DE-ENERGIZE all input electrical lines before installing or removing terminal connections. Failure to follow safe isolating procedures can result in terminal damage, arc flash occurrences, or complete system component failure.

1

Snap the monitor onto the standard 35mm DIN rail, ensuring the locking clasp fully engages and stabilizes the housing.

2

Connect the dynamic vibration sensor wires to channels 1 through 4, referencing the specific transducer scale factor.

3

Perform shield grounding termination on the common bus rail immediately adjacent to the terminal block entry points.

4

Connect the 24 Vdc power input line, energize the source, and check status LEDs to confirm initial initialization behavior is nominal.

How is this monitor configured without an integrated display?

This unit is parameterized using the dedicated programming software connected via its internal configuration interface. Once configured, it operates as a headless monitor, executing local shutdown functions based on preprogrammed logic.

Does this module supply power directly to connected vibration sensors?

Yes, it provides the required sensor excitation loop power for standard proximity probes, accelerometers, or Velomitors on each of its four dynamic input channels.

Can this specific unit be converted to include a local display later?

No, because the display option is determined by physical internal hardware during assembly. Upgrading to a display version requires changing to a different option configuration.

What is the function of the CN approval option on this device?

The CN option indicates the unit carries regulatory and electrical conformity approvals specified for industrial equipment deployments within regional Chinese jurisdictions.

Global Express Shipping

  • Standard Delivery: 4-6 Business Days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries, including rapid delivery to Saudi Arabia and UAE.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our professional technical warranty.

Orders are processed and delivered Monday-Friday (excluding public holidays).


For full eligibility, restocking fees, and international return details, please view our official Refund & Return Policy .

TECHNICAL SPECIFICATIONS

Country of origin
United States

Recently Viewed Products

Technical knowledge

Implementing 3-Switch XOR Ladder Logic with Internal Bit

Implement a 3-SPST switch XOR light circuit in LogixPro or RSLogix 500 using an internal relay bit. Includes truth tables, boolean equations, and verified.

Building a Modbus RTU Network with CompactLogix and DeltaV

Integrate Allen-Bradley CompactLogix, Caterpillar ATS, and generators into DeltaV DCS over Modbus RTU. Covers ProSoft MVI69-MCM, Miille DIN266 gateways.

ONS Instruction Not Energizing OTE in Studio 5000 Ladder Logic

ONS instruction fires but the OTE coil never latches in Studio 5000 because the one-shot is only true for one scan. Use OTL/OTU or seal-in logic instead.

Kinetix 5500 EtherNet/IP Network Switch Requirements and Topology

Configure Allen-Bradley Kinetix 5500 servo drives on EtherNet/IP. Covers CIP Sync, IEEE 1588 V2 timing, Stratix selection, DLR topology, and HMI.

Moving Average Filtering in DCS and PLC Analog Control

A moving-average filter is the sliding-window smoother most instrument engineers drop into DCS and PLC analog paths. Here is how the window works, how N and sample time set lag, and when a...

GE Mark VI Function Blocks for Gas Turbine Control Logic

On Frame 5–9 gas turbines, GE Mark VI and Mark VIe run control as function-block application software. This article maps process, protection, and sequencing functions—and what Toolbox ST access...