1 of 1

Bently Nevada 1900/65A-01-01-03-CN-00 General Purpose Equipment Monitor

Bently Nevada 1900/65A-01-01-03-CN-00 General Purpose Equipment Monitor

Only 5 item(s) left in stock
  • Manufacturer: Bently Nevada

  • Product No.: 1900/65A-01-01-03-CN-00

  • Country of origin:United States

  • Product Type: Vibration Monitoring Systems

  • Payment: T/T, Western Union

  • Weight: 320g

  • Dimensions: 19.69 cm x 14.94 cm x 7.44 cm

  • Shipping port: Xiamen

  • Warranty: 12 months

Quantity
View full details

Description

Designed for continuous machinery protection and critical parameter monitoring, the Bently Nevada 1900/65A-01-01-03-CN-00 provides comprehensive four-channel input capabilities for rotating and reciprocating equipment. This specialized monitor continuously acquires and processes signals from various transducer types, including radial vibration, thrust position, acceleration, velocity, and temperature sensors. By integrating high-accuracy analog monitoring with configurable relay logic, the 1900/65A serves as an independent safety system, executing protective actions to minimize machinery damage and optimize plant uptime.

Features

  • Four-Channel Monitoring: Supports direct inputs from proximity probes, accelerometers, and velocity transducers for multi-point machinery analysis.
  • Integrated Local Display: Features a directly attached display module for real-time local visualization of variable values, status, and system configurations.
  • Configurable Relays: Equipped with onboard relay logic to trigger alarms and executive safety shutdowns based on custom parameters.
  • Rugged Weatherproof Enclosure: Housed in a fiberglass NEMA 4X / IP66 rated enclosure equipped with a viewing window for protection in harsh industrial environments.
  • Auxiliary Inputs: Includes two dedicated temperature or auxiliary inputs supporting RTDs and thermocouples for correlated thermal analysis.

Applications

  • Continuous vibration tracking of industrial motors, pumps, and cooling tower fans.
  • Critical protection for small steam turbines, gas turbines, and hydro-turbines.
  • Thermal and physical expansion monitoring in reciprocating compressor systems.
  • Local safety shutdown integration in oil and gas, power generation, and chemical processing facilities.

Technical Specifications

Manufacturer Bently Nevada
Model Series 1900/65A General Purpose Equipment Monitor
Configuration Part Number 1900/65A-01-01-03-CN-00
Power supply Option (01) 110 to 220 Vac @ 50 to 60 Hz (External Supply)
Display Option (01) Attached display (No interface cable)
Mounting Option (03) Fiberglass NEMA 4X / IP66 Waterproof housing with window in door
Agency Approval Option (CN) Country-specific approvals (China standard compliance)
Communications Option (00) None
Operating Temperature -20 to +70 degC (-4 to +158 degF)
Storage Temperature -30 to +90 degC (-22 to +194 degF)
Humidity Limits 95% relative humidity, non-condensing maximum
Monitor Module Dimensions 19.69 cm x 14.94 cm x 7.44 cm
Display Module Dimensions 19.69 cm x 14.94 cm x 3.28 cm
Shipping Weight (Calculated) 8.0 kg (17.6 lbs)
Country of Origin United States

Empirical Engineering Insights

Alternative Models & Compatibility

The "CN" suffix on this model designates specialized certifications conforming to localized regulatory standards. While functionally identical to standard global 1900/65A modules, field replacement of units in plants governed by specific local audits requires matching this exact suffix to maintain compliance. If you are retrofitting older, unhoused systems, ensure the cabinet depth accounts for the combined thickness of the NEMA housing and window clearances.

Application Pitfalls & Engineering Notes

When utilizing the fiberglass NEMA 4X housing (Option 03) in direct outdoor locations, internal solar gain can raise temperatures inside the enclosure above the rated +70 degC limit. In environments exceeding ambient temperatures of +40 degC, install a physical sunshield over the housing to mitigate thermal buildup and maintain long-term calibration accuracy of the sensitive input channels.

Commissioning & Wiring Tips

Since the "00" option indicates no digital communications, all alert structures rely on the local relays. Always configure the relays for fail-safe operation (normally energized), ensuring that a complete monitor power failure will initiate an alarm trip. Route all sensor input coaxial cables through isolated conduit, maintaining a minimum 30 cm distance from high-voltage motor feeds to prevent induction noise on the sensor readings.

Installation Guidelines

CRITICAL SAFETY WARNING

Isolate and de-energize all power lines leading to the enclosure prior to mounting or connecting transducers. High AC voltages are present within the enclosure at the external supply terminals. Ensure the fiberglass chassis is bonded to local earth ground to prevent electrical shock hazards and control signal drift.

1

Mount the fiberglass enclosure securely using external bracket mounts, ensuring the transparent door window is positioned for unobstructed local display inspection.

2

Lead standard AC input power (110 to 220 Vac) through localized IP-rated cable glands to the monitor terminal block, securing grounding paths.

3

Wire the vibration sensor shields to the internal instrument shield terminals, ensuring shielding continuity without forming secondary ground connections.

4

Configure channel measurement types, trigger setpoints, and relay logical associations via the local display interface before starting machine operation.

Loading product navigation…

What is the primary power configuration of the 1900/65A-01-01-03-CN-00?

This monitor features the 01 option, configuring it for external supply operations matching standard 110 to 220 Vac inputs at 50 to 60 Hz.

Can I run digital communication networks like Modbus TCP with this model?

No, this specific configuration includes the '00' communications option, meaning no external network interface is configured. System alerts and indicators must rely on physical relay outputs.

What types of sensors can be connected to the four primary channels?

The primary monitoring channels are compatible with proximity transducers, accelerometers, and velocity sensors for radial and mechanical vibration profiling.

Does the CN approval suffix mean physical hardware changes?

Functionally, the system operates identically to global models. The 'CN' suffix specifies region-certified approvals and testing compliance parameters for local regulatory markets.

Global Express Shipping

  • Standard Delivery: 4-6 Business Days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries, including rapid delivery to Saudi Arabia and UAE.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our professional technical warranty.

Orders are processed and delivered Monday-Friday (excluding public holidays).


For full eligibility, restocking fees, and international return details, please view our official Refund & Return Policy .

TECHNICAL SPECIFICATIONS

Country of origin
United States

Recently Viewed Products

Technical knowledge

Math Operations Using OpenPLC for Industrial Automation Applications

This article explains how PLC systems perform core mathematical operations such as addition, subtraction, multiplication, division, modulo, and exponentiation within industrial automation. It shows...

Advanced Boolean Logic with FBD PLC Programming: Practical Industrial Applications Beyond Basic Logic

The article explains several advanced Boolean logic functions used in PLC programming beyond basic AND, OR, and NOT operations. It covers how tools like truth tables, multiplexers, pulse generators,...

Boolean Logic in PLC Programming: Understanding FBD Logic Gates

Boolean logic is the foundation of every PLC program. From simple machine controls to complex industrial automation systems, logic gates determine how controllers respond to changing inputs and...

Deep-Dive Guide to Industrial Firewalls and OT Network Segmentation

Industrial firewalls play a critical role in OT cybersecurity, protecting PLC, DCS, and SCADA networks through segmentation, ingress/egress control, and IDS/IPS integration aligned with IEC 62443...

Guide to Robotic Grippers: From Delicate Handling to Heavy-Duty Automation

Modern robotic grippers are evolving beyond traditional mechanical jaws. From gecko-inspired adhesive systems and soft food-grade grippers to AI-powered warehouse tools, advanced gripping...

Throwback: How Early Electric Motors Changed Underground Mining

From rope-driven DC compressors to battery-powered mine carts, early mining operations marked a turning point in industrial electrification. This article explores how electric motors transformed...