Bently Nevada

Bently Nevada 31000-00-00-00-082-03-02 Proximity Probe Housing Assembly

SKU 31000-00-00-00-082-03-02

In stock
  • 12-month warranty
  • Free returns within 30 days
  • Manufacturer: Bently Nevada

  • Product No.: 31000-00-00-00-082-03-02

  • Country of origin:United States

  • Product Type: English Proximity Probe Housing Assemblies

  • Barcode: 8537101190

  • Payment: T/T, Western Union

  • Weight: 1200g

  • Dimensions: 30.02cm x 12cm x 9.14cm

  • Shipping port: Xiamen

  • Warranty: 12 months

Description

The 31000-00-00-00-082-03-02 is a professional-grade proximity probe housing assembly from Bently Nevada, specifically configured for machinery vibration and position monitoring applications. This unit serves as a robust protective enclosure for proximity probes, facilitating external access for gap adjustments or probe replacement without requiring machine disassembly. This configuration includes Option 00 for probe and cable (not installed), Option 082 for an 82 mm probe penetration, Option 03 for fittings (two plugs, one M20 fitting), and Option 02 for 3/4-14 NPT mounting threads.

Constructed from high-strength polyphenylene sulfide (PPS) and corrosion-resistant stainless steel, this housing assembly provides superior environmental protection. It complies with API 670 standards for externally mounted proximity probe housings and is suitable for use in demanding industrial environments, including oil and gas, petrochemical, and power generation facilities.

Features

  • Housing Material: High-strength, corrosion-resistant polyphenylene sulfide (PPS) with stainless steel components.
  • Probe Penetration: 82 mm (Option 082) for standard mounting depth requirements.
  • Fittings: Equipped with two plugs and one M20 fitting (Option 03).
  • Mounting Thread: 3/4-14 NPT thread (Option 02).
  • Access: Designed to allow probe gap adjustment and replacement without machine casing disassembly.
  • Compliance: Fully compliant with API 670 standards for externally mounted proximity probe housings.

Applications

  • Radial vibration measurement on rotating machinery.
  • Keyphasor measurements.
  • Industrial environments requiring mechanical and environmental protection for transducer systems.
  • Fluid-film bearing monitoring in large rotating equipment.

Ordering Information

Option Code on This SKU Description
Orderable Part Number 31000-00-00-00-082-03-02 Proximity Probe Housing Assembly
A - Probe with Connector 00 Probe not required
B - Probe Cable Length 00 Probe cable not required
C - Standoff Adapter Length 00 No standoff adapter
D - Probe Penetration 082 82 mm penetration
E - Fittings 03 Two plugs, one M20 fitting
F - Mounting Thread 02 3/4-14 NPT

Technical Specifications

Parameter Specification
Manufacturer Bently Nevada (Baker Hughes)
Part Number 31000-00-00-00-082-03-02
Housing Material Polyphenylene sulfide (PPS), Stainless steel
Mounting Thread 3/4-14 NPT
Fittings Two plugs, one M20 fitting
Probe Penetration 82 mm
Standard Compliance API 670

Installation Guidelines

The 31000 housing assembly should be installed by sliding the outer sleeve into the machine case, followed by the insertion of the probe sleeve to adjust the necessary probe gap. Ensure the housing is securely fitted over the outer sleeve and the retainer is correctly positioned under the retaining nut. For optimal performance, especially in hazardous areas, ensure the unit is installed with an approved transducer system and appropriate I.S. barriers.

FAQ

What does the 082 option code represent for this housing?

The 082 option code specifies an 82 mm probe penetration length, defining how far the probe extends into the machine casing.

Is this housing compatible with existing 3300 XL proximity probes?

Yes, the 31000 housing series is designed to accommodate 3300 XL series probes, although this specific SKU (Option A: 00) is supplied without an installed probe.

Can this housing be used for axial position measurements?

While this housing is primarily recommended for radially mounted transducers, if measuring shaft axial position with dual proximity probes, Bently Nevada recommends using housing 21022 instead.

What is the material composition of the housing?

The housing is constructed from polyphenylene sulfide (PPS), a high-strength thermoplastic with excellent corrosion resistance, complemented by corrosion-resistant stainless steel elements.

View all FAQs →

Product Documentation

Technical Datasheet (PDF) Complete specifications and technical drawings.

Technical Datasheet

Bently Nevada 31000-00-00-00-082-03-02 Proximity Probe Housing Assembly

Quantity
Shipping & Returns

Global Express Shipping

  • Standard Delivery: 4–6 business days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our technical warranty.
Reviews
1 of 3
Only 2 item(s) left in stock
Quantity
View full details

Global Express Shipping

  • Standard Delivery: 4-6 Business Days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries, including rapid delivery to Saudi Arabia and UAE.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our professional technical warranty.

Orders are processed and delivered Monday-Friday (excluding public holidays).


For full eligibility, restocking fees, and international return details, please view our official Refund & Return Policy .

TECHNICAL SPECIFICATIONS

Country of origin
United States

Technical knowledge

Diagnosing IC693MDL916 Relay Outputs Before Module Replacement

A field checklist for IC693MDL916 relay commands, terminal blocks, load current, switching rate and contact-side measurements.

Troubleshooting Beckhoff KL1512 Counter Inputs and Mapping

A field checklist for KL1512 signal thresholds, counter direction, process data and the KL1512-to-KS1512 wiring difference.

Troubleshooting Beckhoff EPP2008-0001 Output Faults

A field checklist for EPP2008-0001 current limits, supply voltage, channel LEDs, connector coding and load-related output faults.

Moving TwinCAT 3 Licenses with C9900-L100: Build and Device Checks

Before moving a TwinCAT 3 license with a Beckhoff C9900-L100, verify the TwinCAT build, XML device description, exact order code and cabinet limits.

Replacing a Beckhoff EL4032: Wiring and Output Checks

A field checklist for replacing a Beckhoff EL4032, covering the ±10 V load, terminal map, power contacts, EtherCAT state, and watchdog behavior.

Replacing Yokogawa AAI835: Wiring and Barrier Checks Before Swap

Before replacing a Yokogawa AAI835, verify the 4-in/4-out channel map, power-loss loop behavior, barrier type, output load, cable, and redundancy.