Derivative Action in PID Control Without Noise Problems
Learn what derivative action contributes to a PID loop, why it can amplify measurement noise and setpoint changes, and how filtering, sampling, and staged tests make D tuning safer.
Manufacturer: Bently Nevada
Product No.: 330103-00-05-05-02-00
Country of origin:United States
Product Type: 3300 XL 8 mm Proximity Probe
Barcode: 8537101190
Payment: T/T, Western Union
Weight: 140g
Dimensions: 45 mm x 95 mm x 95 mm (H x W x D)
Shipping port: Xiamen
Warranty: 12 months
330103-00-05-05-02-00 is an 8 mm proximity probe from the Bently Nevada 3300 XL transducer system, featuring an M10 x 1 thread, 0.0 in unthreaded length (Option 00), 0.5 in case length (Option 05), and 0.5 m system length (Option 05). This probe is designed for non-contact eddy-current displacement measurements, providing accurate shaft vibration and axial position data in critical rotating machinery environments.
This configuration includes the Miniature coaxial ClickLoc connector without a connector protector (Option 02) and requires no hazardous area agency approvals (Option 00). As part of the 3300 XL system, it is compatible with 3300 XL Proximitor sensors and extension cables, forming a complete measurement chain that maintains signal integrity and system linearity across various industrial operating temperatures.
| Option | Code on This SKU | Description |
|---|---|---|
| Orderable Part Number | 330103-00-05-05-02-00 | 3300 XL 8 mm Proximity Probe, M10 x 1 |
| A - Unthreaded Length | 00 | 0.0 in (fully threaded) |
| B - Overall Case Length | 05 | 0.5 in |
| C - Total Length | 05 | 0.5 m |
| D - Connector/Cable | 02 | Miniature coaxial ClickLoc, standard cable |
| E - Agency Approval | 00 | Not required |
| Manufacturer | Bently Nevada (Baker Hughes) |
| Part Number | 330103-00-05-05-02-00 |
| Probe Diameter | 8 mm |
| Thread Size | M10 x 1 |
| Case Length | 0.5 in |
| Total Length | 0.5 m |
| Connector Type | Miniature coaxial ClickLoc |
| Agency Approvals | None (Option 00) |
| System Compatibility | 3300 XL Proximitor Sensor, 3300 XL Extension Cable |
Ensure the probe is gapped correctly according to the 3300 XL system manual for the specific machine application. Use the appropriate mounting bracket to secure the probe, ensuring it is electrically isolated if required by the specific bearing or housing installation. Connector protectors are recommended for all field connections to prevent environmental degradation and ensure long-term signal reliability.
Global Express Shipping
Returns & Warranty



Global Express Shipping
Returns & Warranty
Orders are processed and delivered Monday-Friday (excluding public holidays).
For full eligibility, restocking fees, and international return details, please view our official Refund & Return Policy .
| Country of origin |
United States
|