Implementing 3-Switch XOR Ladder Logic with Internal Bit
Implement a 3-SPST switch XOR light circuit in LogixPro or RSLogix 500 using an internal relay bit. Includes truth tables, boolean equations, and verified.
Engineered for continuous industrial vibration and shaft position monitoring, the Bently Nevada 330103-00-18-10-02-00 operates as a core transducer element within the 3300 XL 8mm Proximity Transducer System. This eddy current proximity probe delivers precise, non-contact measurements of static and dynamic shaft movement, making it indispensable for critical machinery protection systems. Its rugged mechanical design is optimized for high-pressure, fluid-film bearing environments typical of heavy rotating machinery.
| Parameter | Specification Value |
|---|---|
| Manufacturer | Bently Nevada (Baker Hughes) |
| Model Series | 3300 XL 8mm Proximity Transducer System |
| Part Number | 330103-00-18-10-02-00 |
| Thread Type | 3/8-24 UNF thread (fractional standard casing) |
| Unthreaded Length | 0.0 inches (0 mm) |
| Overall Case Length | 1.8 inches (180 mm option code) |
| Total Length | 1.0 meter (3.3 feet) |
| Connector and Cable Type | Miniature coaxial ClickLoc connector, standard cable |
| Agency Approvals | Not required (Option 00) |
| Operating Temperature Range | -51 degC to +177 degC (-60 degF to +350 degF) |
| Shipping Weight (Calculated) | 2.0 kg |
This proximity probe terminates in a miniature gold-plated coaxial ClickLoc connector. It must be paired with a compatible 3300 XL extension cable to interface with the matching 3300 XL Proximitor Sensor.
| Connection Point | Interface Type | Function / Shielding |
|---|---|---|
| Coaxial Center Conductor | Miniature Coaxial Male | Carries RF excitation and demodulated displacement signals |
| Coaxial Outer Shield | ClickLoc Sleeve (Female Outer) | Provides common return path and continuous EMI shielding |
Because this probe is a 1.0-meter configuration, it is critical to pair it with a system engineered for the correct total electrical length (typically 5-meter or 9-meter systems). For a standard 5.0-meter calibration loop, this probe requires a 4.0-meter extension cable. Attempting to mix 1.0-meter probes with 9-meter extension cables without proper Proximitor recalibration will introduce severe non-linearity errors in the scale factor.
Ensure adequate side clearance during installation. Standard 8mm probes require a minimum of 15.2 mm (0.6 inches) of clearance from adjacent metals. If the probe is mounted too close to a counterbore or bracket, the eddy current field will interact with the surrounding metal, causing false gap voltage readings and flattening the dynamic response curve.
Always use a connector protector or self-fusing silicone tape on the ClickLoc connection if the junction is exposed to oil mist or moisture inside the bearing housing. Before final tightening of the mounting nuts, verify the gap voltage using a digital multimeter at the Proximitor's "OUT" and "COM" terminals; a standard gap voltage of approximately -10 VDC corresponds to the midpoint of the linear range.
Verify that the machine is completely de-energized and locked out before inserting or adjusting the proximity probe. Ensure that all electrical connections to the monitoring system are powered down to prevent damage to sensitive RF circuitry during probe installation.
Global Express Shipping
Returns & Warranty

Engineered for continuous industrial vibration and shaft position monitoring, the Bently Nevada 330103-00-18-10-02-00 operates as a core transducer element within the 3300 XL 8mm Proximity Transducer System. This eddy current proximity probe delivers precise, non-contact measurements of static and dynamic shaft movement, making it indispensable for critical machinery protection systems. Its rugged mechanical design is optimized for high-pressure, fluid-film bearing environments typical of heavy rotating machinery.
| Parameter | Specification Value |
|---|---|
| Manufacturer | Bently Nevada (Baker Hughes) |
| Model Series | 3300 XL 8mm Proximity Transducer System |
| Part Number | 330103-00-18-10-02-00 |
| Thread Type | 3/8-24 UNF thread (fractional standard casing) |
| Unthreaded Length | 0.0 inches (0 mm) |
| Overall Case Length | 1.8 inches (180 mm option code) |
| Total Length | 1.0 meter (3.3 feet) |
| Connector and Cable Type | Miniature coaxial ClickLoc connector, standard cable |
| Agency Approvals | Not required (Option 00) |
| Operating Temperature Range | -51 degC to +177 degC (-60 degF to +350 degF) |
| Shipping Weight (Calculated) | 2.0 kg |
This proximity probe terminates in a miniature gold-plated coaxial ClickLoc connector. It must be paired with a compatible 3300 XL extension cable to interface with the matching 3300 XL Proximitor Sensor.
| Connection Point | Interface Type | Function / Shielding |
|---|---|---|
| Coaxial Center Conductor | Miniature Coaxial Male | Carries RF excitation and demodulated displacement signals |
| Coaxial Outer Shield | ClickLoc Sleeve (Female Outer) | Provides common return path and continuous EMI shielding |
Because this probe is a 1.0-meter configuration, it is critical to pair it with a system engineered for the correct total electrical length (typically 5-meter or 9-meter systems). For a standard 5.0-meter calibration loop, this probe requires a 4.0-meter extension cable. Attempting to mix 1.0-meter probes with 9-meter extension cables without proper Proximitor recalibration will introduce severe non-linearity errors in the scale factor.
Ensure adequate side clearance during installation. Standard 8mm probes require a minimum of 15.2 mm (0.6 inches) of clearance from adjacent metals. If the probe is mounted too close to a counterbore or bracket, the eddy current field will interact with the surrounding metal, causing false gap voltage readings and flattening the dynamic response curve.
Always use a connector protector or self-fusing silicone tape on the ClickLoc connection if the junction is exposed to oil mist or moisture inside the bearing housing. Before final tightening of the mounting nuts, verify the gap voltage using a digital multimeter at the Proximitor's "OUT" and "COM" terminals; a standard gap voltage of approximately -10 VDC corresponds to the midpoint of the linear range.
Verify that the machine is completely de-energized and locked out before inserting or adjusting the proximity probe. Ensure that all electrical connections to the monitoring system are powered down to prevent damage to sensitive RF circuitry during probe installation.
Global Express Shipping
Returns & Warranty
Orders are processed and delivered Monday-Friday (excluding public holidays).
For full eligibility, restocking fees, and international return details, please view our official Refund & Return Policy .
| Country of origin |