Option 08 (0.8 in unthreaded length) and Option 24 (2.4 in overall case length) specify this non-armored 3300 5 mm proximity probe configuration — 330171-08-24-10-02-00.
This configuration is supplied with a 1.0 m (3.3 feet) integrated total cable length (Option 10) terminated with a gold-plated miniature coaxial ClickLoc connector on standard FEP-insulated coaxial cable (Option 02) without a separate connector protector. It does not carry hazardous area agency certifications (Option 00), rendering it suitable for standard safe-area industrial machinery layouts. Built with a reduced 5.2 mm (0.21 in) tip diameter, this probe fits into confined mechanical spaces where standard 8 mm probes cannot be deployed, such as narrow spaces between thrust bearing pads, while delivering identical electrical performance characteristics within compatible 3300 XL transducer systems.
Features
- Option 08 unthreaded case length of 0.8 inches for exact mechanical depth calibration.
- Option 24 overall case length of 2.4 inches with 1/4-28 UNF thread profile.
- Option 10 integrated total cable length of 1.0 meter (3.3 feet).
- Option 02 miniature coaxial ClickLoc connector with robust gold-plated brass contacts.
- Non-armored standard coaxial cable with chemical-resistant FEP insulation.
- Reduced 5.2 mm (0.21 in) probe tip diameter for installation in constrained mechanical envelopes.
- Standard non-approval configuration (Option 00) for general industrial safe-area usage.
Applications
- Radial shaft vibration and axial shaft position monitoring on high-speed rotating machinery.
- Thrust bearing clearances and position measurements within tight internal clearances.
- Rotational speed and Keyphasor phase reference measurements on fluid-film bearing machines.
Ordering Information
| Option Segment |
Code on This SKU |
Description / Specification |
| Orderable Part Number |
330171-08-24-10-02-00 |
3300 5 mm Proximity Probe, 1/4-28 UNF-2A thread, non-armored |
| A - Unthreaded Length Option |
08 |
0.8 in (orderable in increments of 0.1 in; maximum 8.8 in, minimum 0.0 in) |
| B - Overall Case Length Option |
24 |
2.4 in (orderable in increments of 0.1 in; maximum 9.6 in, minimum 0.8 in) |
| C - Total Length Option |
10 |
1.0 meter (3.3 feet) |
| D - Connector Option |
02 |
Miniature coaxial ClickLoc connector, standard cable |
| E - Agency Approval Option |
00 |
No approvals required (Agency Approval Option not required) |
Technical Specifications
| Manufacturer |
Bently Nevada (Baker Hughes) |
| Part Number / SKU |
330171-08-24-10-02-00 |
| Probe Type |
3300 5 mm Proximity Probe |
| Thread Size |
1/4-28 UNF-2A |
| Armor Option |
Without armor (Non-armored standard coaxial cable) |
| Linear Range |
2.0 mm (80 mils), starting at 0.25 mm (10 mils) from target (from 0.25 to 2.3 mm / 10 to 90 mils) |
| Recommended Gap Setting |
1.27 mm (50 mils) |
| Incremental Scale Factor (ISF) |
7.87 V/mm (200 mV/mil) +/-6.5% typical (measured with AISI 4140 steel target) |
| Deviation from Best Fit Straight Line (DSL) |
Less than +/-0.038 mm (+/-1.5 mils) typical deviation |
| Frequency Response |
0 to 10 kHz: +0, -3 dB (with up to 305 m of field wiring) |
| Minimum Target Size |
15.2 mm (0.6 in) diameter (flat target) |
| Shaft Diameter Limits |
Minimum: 50.8 mm (2 in), Recommended minimum: 76.2 mm (3 in) |
| Probe DC Resistance |
7.59 +/- 0.50 Ohms (nominal resistance for 1.0 m length) |
| Cable Capacitance |
69.9 pF/m (21.3 pF/ft) typical |
| Probe Operating Temperature |
-35 degC to +177 degC (-31 degF to +351 degF) |
| Pressure Seal Rating |
Seals differential pressure using internal fluorocarbon O-ring between tip and case |
| Probe Tip Diameter |
5.2 mm (0.21 in) maximum |
| Wrench Flat Size |
5.6 mm (7/32 in) |
| Connector Type |
Miniature gold-plated brass male coaxial ClickLoc connector |
Installation Guidelines
-
Unthreaded Length Clearance: Maintain correct offsets; the unthreaded case length must be at least 0.8 inches less than the overall case length to prevent thread binding or inadequate engagement.
-
Connector Hand-Tightening: Standard ClickLoc connectors must be finger-tightened until a tactile "click" is felt. Do not apply wrenches or special tools to the miniature coaxial coupling.
-
Environmental Protection: Since this SKU has standard cable without a connector protector (Option 02), we recommend utilizing silicone tape or acquiring separate connector protectors if the probe-to-cable junction is exposed to machine fluids or ambient moisture.
-
Lock Nut Torque: Secure the 1/4-28 UNF thread with the supplied lock nut (provided with standard 13 mm or 7/16 in hexagonal dimensions) to prevent loosening under high vibration.
-
Tap Drill Selection: Use a #3 or larger tap drill size when preparing mounting holes for 1/4-28 UNF-2A probes to prevent thread binding.
Compliance and Certifications
-
FCC: Complies with Part 15 of FCC Rules.
-
EMC: Meets standards EN 61000-6-2, EN 61000-6-4, and EMC Directive 2014/30/EU.
-
RoHS: Compliant with Directive 2011/65/EU.
-
Maritime: Certified under ABS 2009 Steel Vessels Rules (1-1-4/7.7, 4-8-3/1.11.1, and 4-9-7/13).