1 of 1

Bently Nevada 330195-02-12-90-CN 3300 XL 8 mm Extension Cable

Bently Nevada 330195-02-12-90-CN 3300 XL 8 mm Extension Cable

Only 2 item(s) left in stock
  • Manufacturer: Bently Nevada

  • Product No.: 330195-02-12-90-CN

  • Country of origin:United States

  • Product Type: Vibration Monitoring Extension Cables

  • Payment: T/T, Western Union

  • Weight: 320g

  • Shipping port: Xiamen

  • Warranty: 12 months

Quantity
View full details

Description

Optimized for demanding machinery protection applications, the Bently Nevada 330195-02-12-90-CN functions as a high-performance 3300 XL 8 mm Extension Cable within the standard eddy current transducer system. This cable bridges the physical distance between the proximity probe and the Proximitor sensor, ensuring precise capacitive and inductive matching necessary for accurate vibration and shaft position measurements. Featuring FluidLoc technology and an integrated connector protector, this model is specifically engineered to resist process fluid migration and mechanical stress in harsh industrial environments, while carrying the necessary regional certification approvals.

Features

  • FluidLoc Cable Design: Prevents the leakage of oil, water, or other process fluids through the inner core of the coaxial cable.
  • Connector Protector: Provides robust mechanical shielding and environmental sealing at the critical probe-to-extension-cable junction.
  • Precision Coaxial Shielding: Minimizes electromagnetic interference (EMI) and radio frequency interference (RFI) to maintain signal integrity over the entire length.
  • High Temperature Stability: Constructed with materials designed to withstand extreme temperature fluctuations within industrial casings.
  • Certified Design: Designed with the CN option, meeting regional compliance and hazardous area standards.

Applications

  • Steam and gas turbine shaft vibration and axial displacement monitoring.
  • Centrifugal compressor and high-pressure pump shaft dynamic motion analysis.
  • Hydroelectric generator thrust collar and guide bearing monitoring.
  • Heavy industrial gearbox shaft thrust and radial position tracking.

Technical Specifications

Manufacturer Bently Nevada
Model Number 330195-02-12-90-CN
Product Series 3300 XL 8 mm Proximity Transducer System
Cable Length 2.0 meters (6.6 feet)
Total System Length Compatibility 9.0 meters (29.5 feet)
Cable Configuration Option FluidLoc Cable with Connector Protector
Agency Approvals CN Option (Country-specific approvals / hazardous area certifications)
Operating Temperature Range -51 degC to +177 degC (-60 degF to +350 degF)
Nominal Impedance 75 ohms
Country of Origin United States (U.S.A.)
Shipping Weight (Calculated) 1.5 kg (3.3 lbs)

Connections and Interfaces

Connection Port Connector Type Protective Feature
Probe Interface Miniature Coaxial Male Integrated Connector Protector installed
Proximitor Sensor Interface Miniature Coaxial Female Standard silicon protective boot compatible

Empirical Engineering Insights

Alternative Models & Compatibility: The 330195-02-12-90-CN is strictly calibrated for 9.0-meter system configurations. It cannot be combined with a 5.0-meter Proximitor sensor or 5.0-meter probe configurations. Mismatching system lengths alters the total electrical capacitance of the sensor loop, leading to severe measurement non-linearity, gain errors, and invalid machinery protection alarms.

Application Pitfalls & Engineering Notes: When routing the extension cable, mechanical protection is paramount. Maintain a minimum bend radius of 25.4 mm (1.0 inch). Kinking or flattening the cable distorts the coaxial spacing between the center conductor and the outer shield, changing the characteristic impedance from 75 ohms and introducing high-frequency noise spikes that can be misidentified as machine vibration.

Commissioning & Wiring Tips: Ensure that the miniature coaxial connectors are completely clean and dry before mating. Moisture or particulate ingress inside the connector creates a high-resistance parallel path to ground, generating a drift in the gap voltage and triggering sensor fault codes in the 3500 rack. The FluidLoc and connector protector features must be correctly engaged and sealed during the final layout.

Installation Guidelines

CRITICAL WARNING

Ensure the machinery is completely de-energized, locked out, and tagged out (LOTO) prior to accessing probe housings. Discharge all residual electrostatic charges from your body and routing conduits before handling the coaxial connectors to prevent permanent electrostatic damage to the connected Proximitor sensor.

1
Route the extension cable through dedicated, grounded metal conduit. Avoid running the coaxial cable in the same cable trays or parallel paths with high-voltage AC power lines.
2
Connect the miniature coaxial interfaces carefully. Tighten the connectors to the recommended finger-tight torque. Do not use pliers or heavy tools on the miniature connectors, as this will strip the threads.
3
Slide the connector protector over the mated junction until it is firmly locked, providing mechanical and environmental sealing against steam, oil, and humidity.
Loading product navigation…

What does the -12 option signify in the 330195-02-12-90-CN model code?

The -12 option represents the FluidLoc cable configuration with an integrated connector protector. The FluidLoc technology prevents fluids from traveling inside the cable core, while the protector guards the physical coaxial joint from environmental contamination.

What is the physical length of the 330195-02-12-90-CN extension cable?

The physical cable length is 2.0 meters (6.6 feet), specified by the -02 option. The -90 option indicates it is calibrated for use in a total system length of 9.0 meters (29.5 feet).

Can I use this cable with non-XL 3300 series proximity probes?

Yes, but with limitations. While physical connections are compatible, mixing 3300 and 3300 XL components can affect system calibration parameters. For maximum accuracy and compliance, it is highly recommended to pair with other 3300 XL series components.

What are the grounding requirements for the 330195 extension cable?

The outer shield of the extension cable is electrically isolated from the machinery ground inside the conduit. System grounding must be handled solely at the Proximitor sensor side to prevent electrical ground loops that introduce signal noise.

Global Express Shipping

  • Standard Delivery: 4-6 Business Days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries, including rapid delivery to Saudi Arabia and UAE.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our professional technical warranty.

Orders are processed and delivered Monday-Friday (excluding public holidays).


For full eligibility, restocking fees, and international return details, please view our official Refund & Return Policy .

TECHNICAL SPECIFICATIONS

Country of origin
United States

Recently Viewed Products

Technical knowledge

Electric Actuators Designed to Replace Fluid Power Systems: A Practical Industrial Automation Guide

This article explains how integrated electric actuators, such as SMC’s e-Actuator series, are transforming industrial motion control by replacing traditional pneumatic and hydraulic systems. It...

Math Operations Using OpenPLC for Industrial Automation Applications

This article explains how PLC systems perform core mathematical operations such as addition, subtraction, multiplication, division, modulo, and exponentiation within industrial automation. It shows...

Advanced Boolean Logic with FBD PLC Programming: Practical Industrial Applications Beyond Basic Logic

The article explains several advanced Boolean logic functions used in PLC programming beyond basic AND, OR, and NOT operations. It covers how tools like truth tables, multiplexers, pulse generators,...

Boolean Logic in PLC Programming: Understanding FBD Logic Gates

Boolean logic is the foundation of every PLC program. From simple machine controls to complex industrial automation systems, logic gates determine how controllers respond to changing inputs and...

Deep-Dive Guide to Industrial Firewalls and OT Network Segmentation

Industrial firewalls play a critical role in OT cybersecurity, protecting PLC, DCS, and SCADA networks through segmentation, ingress/egress control, and IDS/IPS integration aligned with IEC 62443...

Guide to Robotic Grippers: From Delicate Handling to Heavy-Duty Automation

Modern robotic grippers are evolving beyond traditional mechanical jaws. From gecko-inspired adhesive systems and soft food-grade grippers to AI-powered warehouse tools, advanced gripping...