Description
330850-91-05: 3300 XL 25 mm Proximitor Sensor configured for a 9.0-metre system length with integrated DIN-mount support (Option 91) and multiple hazardous area agency approvals (Option 05).
This Proximitor sensor is calibrated to pair with a 3300 XL 25 mm proximity probe and a matching extension cable to form a complete 9.0-metre transducer system. Compared to panel-mount configurations or shorter 5.0-metre systems, this model features a pre-installed DIN-mount pad that allows secure installation onto standard 35 mm DIN rails, simplifying industrial enclosure layouts. It is calibrated by default for AISI 4140 steel targets, serving large-target eddy-current displacement measurements such as steam turbine thrust position and differential expansion.
Features
- Option 91 provides 9.0-metre total system length calibration, matching the combined electrical length of the probe and extension cable.
- DIN-mount mounting pad (Option 91) facilitates rapid installation onto standard 35 mm DIN rails.
- Option 05 Multiple Approvals package offers certified protection for installation in Class I Division 1/2 and Zone 0/1/2 hazardous areas.
- SpringLoc terminal strips provide reliable, tool-free terminal wiring, securing 0.2 to 1.5 mm2 (16 to 24 AWG) field cables.
- Active RF shield design minimizes interference from nearby high-frequency radio signals, preserving sensor accuracy.
Applications
- Steam turbine thrust position monitoring
- Differential expansion measurement on high-capacity rotating machinery
- Large shaft target axial displacement tracking
- Rod-drop monitoring in reciprocating compressors
Ordering Information
| Option / Segment |
Code on This SKU |
Description |
| Orderable Part Number |
330850-91-05 |
3300 XL 25 mm Proximitor Sensor |
| A - System Length and Mounting |
91 |
9.0 metres (29.5 feet) system length, DIN mount |
| B - Agency Approval Option |
05 |
Multiple Approvals (CSA, ATEX, IECEx, etc.) |
Technical Specifications
| Manufacturer |
Bently Nevada (Baker Hughes) |
| Part Number / Model |
330850-91-05 |
| Transducer System |
3300 XL 25 mm Proximity Transducer System |
| Linear Range |
12.7 mm (500 mils), beginning at approx. 0.63 mm (25 mils) and extending to 13.33 mm (525 mils) |
| Output Signal Range |
-1.5 Vdc to -11.5 Vdc (approximately) |
| Average Scale Factor (ASF) |
0.787 V/mm (20 mV/mil) nominal |
| Deviation from Best Fit Straight Line (DSL) |
Less than +-0.31 mm (+-12 mils) under standard temperatures; remains within +-0.92 mm (+-36 mils) over extended ranges |
| Power Supply Input |
Requires -17.5 Vdc to -26 Vdc (without barriers) at 12 mA maximum consumption; -23 Vdc to -26 Vdc (with barriers) |
| Supply Sensitivity |
Less than 2 mV change in output voltage per volt change in input voltage |
| Output Impedance |
50 ohms |
| Frequency Response |
0 to 2.7 kHz: +0, -3 dB typical (with up to 305 metres of field wiring) |
| Proximitor Material |
A380 aluminum |
| Operating Temperature |
-51 degC to +100 degC (-60 degF to +212 degF) |
| Storage Temperature |
-51 degC to +105 degC (-60 degF to +221 degF) |
| Relative Humidity |
100% condensing, non-submersible when connectors are protected |
Connections and Interfaces
| Terminal / Connector |
Description |
| COM |
Common / Circuit ground return |
| OUT |
Analog output voltage signal (-1.5 Vdc to -11.5 Vdc) |
| VTG |
Negative DC power supply input (-17.5 Vdc to -26 Vdc) |
| Coaxial Jack |
Female miniature coaxial connector for 3300 XL 25 mm extension cable |
Installation Guidelines
- Mount securely on standard 35 mm DIN rail inside an IP54 or better protective enclosure.
- Ensure a minimum clearance of 3.05 mm (0.120 in) is maintained for DIN rail insertion and removal.
- Avoid routing field wiring parallel to high-voltage power cables to mitigate electromagnetic interference.
- Apply self-fusing silicone tape or connector protectors over coaxial connections to prevent moisture contamination.
- Connect the field wiring shield exclusively at the monitor end to eliminate potential ground loop issues.
Compliance and Certifications
-
ATEX/IECEx: Ex ia IIC T5...T1 Ga, Ex ia IIIC T90degC...T280degC Dc, Ex nA IIC T4/T5 Gc, Ex ec IIC T4/T5 Gc
-
CSA/US: Class I, Zone 0: AEx/Ex ia IIC T5...T1 Ga; Class I, Groups A, B, C, D; Class II, Groups E, F, G; Class III
-
CE Mark: Fully compliant with European Union EMC and hazardous area directives