What Is SCADA? Supervisory Control Without Replacing the PLC
SCADA sits above PLCs and RTUs: it acquires field data, alarms operators, and issues supervisory commands across plants and remote assets—without replacing local deterministic control.

Designed for high-precision displacement and vibration measurements on large industrial rotating machinery, the Bently Nevada 330876-03-50-01-00 functions as a critical component of the 3300 XL 50 mm proximity transducer system. This ruggedized 50 mm eddy current sensor is engineered to withstand extreme environment exposures while delivering consistent, non-contacting dynamic measurements. Featuring a robust smooth side-exit case design and a high-temperature FluidLoc cable with protective armor, this probe provides exceptional structural integrity and signal protection in harsh, fluid-exposed industrial settings.
| Parameter / Configuration Option | Specification Value |
|---|---|
| Manufacturer | Bently Nevada |
| Model Series | 3300 XL 50 mm Proximity Transducer System |
| Part Number | 330876-03-50-01-00 |
| Probe Case Option (03) | Smooth 1.99 in diameter, Side Exit |
| Total Length Option (50) | 5.0 meters (16.4 feet) |
| Armor Option (01) | High Temperature FluidLoc Cable with Armor |
| Agency Approval Option (00) | No Approvals |
| Net Weight | 0.59 kg |
| Shipping Weight (Calculated) | 1.50 kg |
| Country of Origin | United States of America (USA) |
Operating and maintaining large-scale machinery sensor networks requires strict adherence to system-level configuration parameters. Below are practical field engineering insights for this specific probe model:
This 50 mm probe is specifically matched to the 3300 XL 50 mm Proximitor Sensor (typically the 330780 series). It is electrically incompatible with standard 3300 XL 8 mm, 11 mm, or 25 mm systems. Replacing a standard probe with this high-displacement probe requires a complete system calibration change, including matching Proximitor sensor electronics and recalibrating the monitoring rack channel configurations.
When routing the high-temperature FluidLoc cable, ensure the stainless steel armor does not rub against sharp structural metal corners. Despite the FluidLoc construction preventing capillary-action fluid migration, constant mechanical vibration can wear through the armor and outer jacket, resulting in ground loops or intermittent shield-to-ground faults. Observe a minimum bend radius of 25.4 mm (1.0 inch) for armored cables during route planning.
Verify the absolute electrical physical system length (probe plus any extension cable) matches the Proximitor's calibrated length rating of 5.0 meters. Mismatched system lengths will distort the RF scale factor, causing significant linearity errors across the probe's expanded measurement range. Clean all coaxial connectors with a zero-residue contact cleaner and secure the connection using the recommended connector protector kits to prevent oil ingress at the junction point.