Description

The Bently Nevada 86497-01-02-02-00 is a high-precision, industrial-grade cylinder pressure transducer engineered specifically for dynamic pressure monitoring on reciprocating compressors and internal combustion engines. This specialized sensor captures high-frequency pressure changes inside active combustion or compression cylinders, transforming physical mechanical stress into an accurate electrical signal path for real-time thermodynamic diagnostics. The 86497-01-02-02-00 interfaces seamlessly with advanced machinery diagnostic platforms, such as the Bently Nevada 3500/77M Reciprocating Cylinder Pressure Monitor or System 1 software, to compute multi-point peak pressure variables, horse-power degradation indexes, and internal valve leakage symptoms.

To withstand the aggressive thermal shocks and chemical exposure typical of cylinder heads, the transducer assembly features a robust, corrosion-resistant stainless steel shell and an optimized piezoelectric sensing element. This specific option string dictates fixed operational boundaries, including standard physical thread patterns, a specialized top integrated connector setup, a specialized high-performance temperature insulation envelope, and default hazardous area approvals, ensuring safe, continuous structural asset protection.

Features

  • Specialized piezoelectric architecture capturing high-speed dynamic pressure waveforms without mechanical lag.
  • Rugged stainless steel housing configuration providing long-term resistance to high-pressure combustion byproducts.
  • Direct compatibility with high-density reciprocating machinery protection racks and thermodynamic analyzer software.
  • Excellent thermal compensation boundaries preventing calibration drift under sustained cyclic heat loads.
  • Low-profile physical footprint designed to fit into standardized cylinder head indicator valve ports.

Applications

  • Real-time dynamic pressure charting and valve condition monitoring on heavy-duty reciprocating process compressors.
  • Continuous combustion balancing and peak pressure calculation across large-bore industrial diesel and natural gas engines.
  • Advanced asset diagnostic reporting and efficiency optimization tracking on balance-of-plant gas pipeline skids.

Ordering Information

Detail Product Ordering Reference
Base Model Designation 86497 (Cylinder Pressure Transducer)
Full Part Code Assembly 86497-01-02-02-00
Full Option Suffix Configuration -01 (Thread Size and Adapter Option)
  -02 (Connector Layout Variant Suffix)
  -02 (Temperature / Performance Range Suffix)
  -00 (Hazardous Area Certifications Option - Standard/None)

Technical Specifications

Parameter Detail
Manufacturer Bently Nevada (Baker Hughes)
Model Designation 86497-01-02-02-00
Product Type Piezoelectric Cylinder Pressure Transducer
Measurement Parameter Dynamic internal cylinder pressure / dynamic gas force
Sensing Element Material Industrial piezoelectric crystal configuration
Enclosure Material Profile High-grade corrosion-resistant stainless steel
Signal Transmission Output Charge or low-impedance voltage waveform proportional to pressure
Thread Size Option Suffix 01 Option Specific Thread Geometry
Connector Interface Block 02 Option Specific Hermetic Connector Interface
Thermal Adaptation Profile 02 Option Specific Temperature Compensation Envelope
Approvals Option Suffix 00 Standard / Non-hazardous industrial placement rating
Hardware Core Layout Rigid body structure designed for structural indicator valve mounting
Operational Weight Reference Industrial standard field pressure sensor assembly weight

Connections/Interfaces

Interface Point Function Assignment
Top Integrated Connector High-insulation pin terminals for low-noise coaxial signal connection
Transducer Mounting Base Threaded mechanical interface for airtight indicator valve block attachment

Installation Guidelines

  • Rigid Port Mounting: Thread the sensor base directly onto the designated cylinder indicator valve port or specialized mounting adapter. Always torque the hex body to the exact engineering layout specifications to verify a leak-free mechanical seal.
  • Coaxial Lead Routing: Connect a specialized low-noise coaxial cable loop to the top connector pins. Route this high-impedance signal run inside separate flexible metal conduit blocks away from high-current motor cables.
  • Thermal Mitigation Loops: Ensure that any integrated internal cooling passages or external protective shields are free from debris blockage to keep operational core temperatures inside the transducer sensor boundaries.
  • Indicator Valve Settings: When performing temporary analytical tests, ensure the physical indicator valve is closed completely prior to mounting or unmounting the pressure transmitter body to prevent high-pressure gas bypass accidents.

FAQ

What primary machinery asset type is this 86497 sensor configuration calibrated to monitor?

The 86497 series transducer is specifically engineered to measure continuous dynamic cylinder pressure profiles inside reciprocating compressors and large internal combustion engines.

Which specific monitoring rack module interfaces with this pressure sensor to compute thermodynamic curves?

This transducer typically interfaces directly with a Bently Nevada 3500/77M Reciprocating Cylinder Pressure Monitor module or equivalent System 1 diagnostic hardware platforms.

What configuration parameters are designated by the trailing -00 suffix in this part number string?

The -00 suffix denotes the standard baseline configuration option for hazardous area certifications, indicating either standard industrial ratings or no additional localized approval variants.

View all FAQs →

Quantity
Shipping & Returns

Global Express Shipping

  • Standard Delivery: 4–6 business days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our technical warranty.
Reviews
1 of 3
Only 4 item(s) left in stock
Quantity
View full details

Global Express Shipping

  • Standard Delivery: 4-6 Business Days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries, including rapid delivery to Saudi Arabia and UAE.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our professional technical warranty.

Orders are processed and delivered Monday-Friday (excluding public holidays).


For full eligibility, restocking fees, and international return details, please view our official Refund & Return Policy .

TECHNICAL SPECIFICATIONS

Color pattern
Greyish White
Country of origin
United States
Power source
DC Power

Technical knowledge

First TwinCAT PLC Project on a Beckhoff IPC

Build and verify a first TwinCAT PLC project on a Beckhoff IPC. This checklist covers target selection, EtherCAT discovery, I/O mapping, safe activation, restart tests, and commissioning records.

Commissioning OPC UA in KEPServerEX: A Field Checklist

A practical commissioning sequence for KEPServerEX OPC UA connections: define data ownership, test tags locally, configure endpoint and certificate trust, limit access, then verify failure recovery...

Set a PLC Commissioning Laptop IP Without Losing Access

Commissioning an Ethernet-connected PLC often starts with the laptop, not the controller. Learn how to record existing settings, choose a temporary address, test connectivity, and restore the plant...

Designing Automation for Combustible Dust Hazards

Combustible dust controls require more than alarms. Learn how to map dust generation, select instrumentation, design interlocks, handle failed feedback, test safe states, and maintain the full...

Hairpin Stators: Benefits, Limits, and Inspection

Hairpin windings raise slot fill and support compact traction motors, but conductor geometry, AC losses, insulation damage, weld quality, and cooling determine whether the design meets its targets.

Using Ansible for Controlled SCADA Server Changes

Use Ansible to standardize SCADA server changes without expanding OT risk. This guide covers inventories, idempotent playbooks, staged testing, credentials, logging, and practical rollback controls.