1 of 3

Bently Nevada 9200-01-05-10-00 Two-Wire Seismoprobe Velocity Transducer

Bently Nevada 9200-01-05-10-00 Two-Wire Seismoprobe Velocity Transducer

Only 7 item(s) left in stock
  • Manufacturer: Bently Nevada

  • Product No.: 9200-01-05-10-00

  • Country of origin:United States

  • Product Type: Seismoprobe Velocity Transducers

  • Barcode: 8537101190

  • Payment: T/T, Western Union

  • Weight: 2000g

  • Dimensions: 180 mm x 120 mm x 100 mm

  • Shipping port: Xiamen

  • Warranty: 12 months

Quantity
View full details

Description

The Bently Nevada 9200-01-05-10-00 is a two-wire moving-coil transducer engineered to evaluate absolute bearing housing, casing, or structural vibration relative to free space. Utilizing specialized electrodynamic moving-coil technology, this sensor output provides a voltage signal directly proportional to the mechanical casing vibration velocity. Due to its mechanical internal architecture, it displays lower susceptibility to localized structural impacts or impulsive excitation compared to conventional solid-state sensors, making it an excellent choice for continuous heavy machinery protection and field diagnostic assessments. Operating as a self-generating device, it functions entirely without external excitation power loops. The configuration code 9200-01-05-10-00 specifies a transducer optimized for horizontal mounting planes (0 ±2.5 degrees) with a low 4.5 Hz minimum operating frequency, an integrated top-mounted terminal block connector, and a circular M10X1 threaded mounting stud.

Features

  • Moving-Coil Architecture: Delivers high immunity to structural transients and localized mechanical shock impacts.
  • Self-Generating Operation: Eliminates external power supply requirements, minimizing field wiring infrastructure.
  • Horizontal Plane Optimization: Pre-configured for a 0 ±2.5 degree mounting alignment, enabling low-frequency tracking down to 4.5 Hz.
  • Top-Mount Terminal Block: Features an integrated polyphenylene sulfide terminal connection with nickel-plated copper contacts, preventing proprietary cable dependencies.
  • Ruggedized Mechanical Housing: Component body constructed from anodized aluminum A204 with durable neoprene environmental sealing gaskets.

Applications

  • Continuous casing vibration monitoring on industrial bearing blocks and rotating machinery housings.
  • Absolute velocity measurements on medium-sized process pumps, cooling fans, and legacy steam turbines.
  • Field data collection, portable machinery balancing, and diagnostic engineering surveys.
  • Structural vibration assessments and misalignment tracking across balance-of-plant rotating equipment.

Ordering Information

Option Code Selection Meaning Technical Value / Detail
9200 Base Transducer Model Two-Wire Seismoprobe Velocity Transducer
01 Mounting Angle / Minimum Frequency 0 ±2.5 degrees, 4.5 Hz (270 cpm)
05 Connector Option Terminal block top mount
10 Mounting Base Option Circular base; M10X1 stud
00 Agency Approval Option No approvals required

Technical Specifications

Parameter Specification Value
Sensitivity 20 mV/mm/s (500 mV/in/s) ±5% at calibration orientation
Frequency Response 4.5 Hz to 1000 Hz (270 to 60,000 cpm); +0, -3 dB typical
Dynamic Operating Range 2.54 mm (0.100 in) peak-to-peak maximum displacement
Velocity Range ±5% tolerance from 0.254 to 127 mm/s (0.01 to 5.0 in/s) at 100 Hz
Coil Resistance 1.25 kOhm ±5%
Locked Coil Inductance 125 mH, typical value
Calibration Test Load 10 kOhm across Terminal A and Terminal B
Sensitivity Temperature Coefficient -0.02% per degC (-0.011% per degF) typical change
Transverse Sensitivity Less than 10% maximum of sensitive axis amplitude at 100 Hz
Shock Resistance Withstands 50 g peak maximum acceleration along non-sensitive axis
Operating Temperature Range -29 degC to +121 degC (-20 degF to +250 degF)
Relative Humidity Range Up to 95%, noncondensing environments
Maximum Use Altitude 2000 meters (6,561 feet) above sea level
Housing & Seal Composition Anodized aluminum A204 body; Neoprene gaskets
Mounting Torque Rating 5.6 N-m (50 in-lb) maximum load on base threaded stud
Physical Dimensions 102 mm total height, 41 mm outer diameter typical
Manufacturer Bently Nevada (A Baker Hughes Company)
Country of Origin U.S.A.
Shipping Weight (Calculated) 2.0 Kg
Package Dimensions (Calculated) 180 mm x 120 mm x 100 mm

Connections and Interfaces

Terminal Designation Function / Circuit Assignment
Terminal A Positive Signal Output (registers positive relative to Terminal B when motion moves toward connector)
Terminal B Negative Signal Return / Reference common

Installation Guidelines

CRITICAL WARNING

Isolate and completely power down all associated machine monitoring loops and field control machinery prior to performing any hardware installation or replacement. Working on active field systems in hazardous areas can generate electrical hazards, induce control loops faults, or trigger unintended machine trip sequences.

Field engineers must strictly observe the following technical sequence during field deployment:

1
Ensure the targeted machinery casing surface is flat-machined, perpendicular to the measurement axis, and clean of paint or oxidation layer buildup.
2
Align the transducer assembly within the specified horizontal mounting orientation criteria of 0 ±2.5 degrees to satisfy low-frequency limits.
3
Apply a calibrated torque wrench to tighten the M10X1 integrated base mounting stud to exactly 5.6 N-m (50 in-lb); do not exceed this limit.
4
Wire twisted, shielded pairs into Terminal A and Terminal B on the top-mounted connection terminal block, ensuring proper conduit sealing to maintain loop integrity.

Product Documentation

Technical Datasheet (PDF) Complete specifications and technical drawings.

Technical Datasheet

Bently Nevada 9200-01-05-10-00 Two-Wire Seismoprobe Velocity Transducer

What is the structural advantage of the moving-coil mechanics in this transducer?

The moving-coil mechanism utilizes a physically suspended internal coil design around a permanent magnet. This arrangement is inherently less sensitive to localized mechanical impacts and high-frequency structural noise compared to solid-state sensors that rely on integrated accelerometers.

Does this velocity sensor require external loop power or excitation voltage?

No. This velocity transducer operates as an electrodynamic self-generating device. The physical movement of the internal coil within the magnetic field produces its own voltage output, requiring zero external excitation power.

What technical parameter is defined by the 01 option code?

The 01 code dictates a horizontal mounting angle orientation calibrated to 0 ±2.5 degrees. This specific architectural constraint allows the velocity sensor to reliably monitor low-frequency vibrations down to 4.5 Hz or 270 cpm.

What is the function of the top-mounted terminal block connector?

The 05 terminal block option provides direct screw-terminal connections on top of the sensor body. This enables the field engineer to utilize standard twisted, shielded instrument wiring paths instead of depending on expensive proprietary cable assemblies.

Global Express Shipping

  • Standard Delivery: 4-6 Business Days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries, including rapid delivery to Saudi Arabia and UAE.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our professional technical warranty.

Orders are processed and delivered Monday-Friday (excluding public holidays).


For full eligibility, restocking fees, and international return details, please view our official Refund & Return Policy .

TECHNICAL SPECIFICATIONS

Color pattern
Black Silver
Country of origin
United States

Recently Viewed Products

Technical knowledge

Modernizing Bailey INFI 90 Symphony HMIs Running on OpenVMS Alpha

A practical guide to replacing aging Bailey Symphony operator stations running on OpenVMS Alpha. It compares Alpha emulation, OpenVMS x86 migration, OPC re-platforming, and phased ABB modernization.

Why Maintenance Data Is Essential for Industrial Reliability

Maintenance data connects work orders, sensor signals, asset history, costs, and technician knowledge. Used well, it improves planning, reliability, predictive maintenance, spare-parts control, and...

Electric Actuators Designed to Replace Fluid Power Systems: A Practical Industrial Automation Guide

This article explains how integrated electric actuators, such as SMC’s e-Actuator series, are transforming industrial motion control by replacing traditional pneumatic and hydraulic systems. It...

Math Operations Using OpenPLC for Industrial Automation Applications

This article explains how PLC systems perform core mathematical operations such as addition, subtraction, multiplication, division, modulo, and exponentiation within industrial automation. It shows...

Advanced Boolean Logic with FBD PLC Programming: Practical Industrial Applications Beyond Basic Logic

The article explains several advanced Boolean logic functions used in PLC programming beyond basic AND, OR, and NOT operations. It covers how tools like truth tables, multiplexers, pulse generators,...

Boolean Logic in PLC Programming: Understanding FBD Logic Gates

Boolean logic is the foundation of every PLC program. From simple machine controls to complex industrial automation systems, logic gates determine how controllers respond to changing inputs and...