Bently Nevada

Bently Nevada AAP1407030-00100 3300 XL NSv Proximity Transducer Probe

SKU AAP1407030-00100

In stock
  • 12-month warranty
  • Free returns within 30 days
  • Manufacturer: Bently Nevada

  • Product No.: AAP1407030-00100

  • Country of origin:United States

  • Product Type: 3300 XL NSv proximity probe

  • Barcode: 8537101190

  • Payment: T/T, Western Union

  • Weight: 100g

  • Dimensions: 20.5cm x 22.5cm x 3.5cm

  • Shipping port: Xiamen

  • Warranty: 12 months

The Bently Nevada AAP1407030-00100 (interchangeable with factory cross-reference code 109548-01 P1407030-00100) is a specialized, non-contact eddy-current eddy-current proximity probe sensor belonging to the high-density 3300 XL NSv (Narrow Side View) Series. Engineered specifically for industrial fluid-film bearing machinery with extremely tight installation spaces, it delivers an optimized radiation footprint to mitigate counterbore, side-view, or rear-view physical restrictions. The probe operates by generating a high-frequency electromagnetic field that measures static gap voltage displacements and dynamic vibration frequencies, transferring accurate shaft position signals to a paired 3300 XL NSv Proximitor Sensor. It is primarily deployed on small-diameter rotating assemblies such as centrifugal air compressors, refrigeration chillers, and process gas turbo-compressors where conventional 5 mm or 8 mm sensor tips encounter structural interference or scale factor distortion from confined housing walls.

Hardware Specifications

Parameter Specification
Transducer Subsystem Type Eddy-current non-contact proximity probe sensor
Target Material Calibration AISI 4140 steel (standard calibration target)
Average Scale Factor (ASF) 7.87 V/mm (200 mV/mil) nominal
Linear Sensing Range 1.5 mm (60 mils)
Linear Range Boundaries 0.25 mm to 1.75 mm (10 mils to 70 mils)
Nominal Voltage Output Span Approximate linear voltage span from -1 VDC to -13 VDC
Incremental Scale Factor (ISF) 7.87 V/mm (200 mV/mil) +12.5% / -20% over ambient limits
Deviation From Best Fit Straight Line Less than ±0.06 mm (±2.3 mils)
Recommended Operational Gap 1.0 mm (40 mils)
Minimum Shaft Target Diameter 30 mm (1.2 in) for standard radial X-Y configurations
Minimum Flat Target Diameter 8.9 mm (0.35 in); 13 mm (0.5 in) recommended minimum
Probe Tip Base Encapsulation Polyphenylene sulfide (PPS) engineering thermoplastic
Probe Case Material Housing AISI 304 stainless steel (SST)
Connector Interface Construction Gold-plated brass coaxial ClickLoc miniature connectors
Internal Pressure Seal Mechanism Integrated Viton O-ring for differential casing containment
Operating Temperature Range -34 °C to +177 °C (-30 °F to +351 °F)
Storage Temperature Profile -52 °C to +105 °C (-62 °F to +221 °F)
Operational Altitude Max Limit 2000 m
Net Item Component Weight 0.10 kg (0.22 lb)

Engineering Notes

  • Scale Factor Stability: For optimal eddy-current scaling, the target face must be flat and symmetric. If measuring on shaft diameters smaller than 30 mm (1.2 in) or flat profiles under 13 mm (0.5 in), reduction of the baseline gap voltage down towards the lower limit of the linear window may be necessary to correct for boundary attenuation.
  • Side-View Clearance: The specialized configuration allows this probe to withstand close proximity to adjacent metallic structures. However, cross-talk or field distortions can occur if the clear side-view path dips below the structural limits of the machine's counterbore geometry.
  • Interchangeability Rules: The probe must be paired exclusively with a 3300 XL NSv Proximitor Sensor and its corresponding 3300 NSv extension cable. Total electrical length configuration must be verified to prevent impedance mismatches across the channel.

Field Guidelines

  • ClickLoc Terminal Torque: Hand-tighten the gold-plated coaxial connectors until a physical, tactile "click" is felt. Never apply pliers or wrenches to the miniature joints, as over-torqueing can fracture the internal center pin conductor.
  • Cable Protection Measures: Use the factory-supplied silicone self-fusing tape to wrap outer connector couplings exposed to moisture or particulate contamination. Avoid deploying silicone wrapping sections within the internal machinery casing.
  • Bending Radius Demands: Maintain a minimum structural bending radius of 25.4 mm (1.0 in) for standard probe leads and armored extensions to prevent macro-bending fractures within the internal coax core.

Technical & Procurement FAQ

Question: How does the AAP1407030-00100 model manage differential pressure inside process compressor casings?

Answer: The sensor case features a dedicated internal Viton O-ring pressure configuration. This barrier acts as a mechanical seal to isolate differential process gases from migrating up the internal probe core and into outer terminal junction boxes.

Question: What is the main differentiator between this NSv series probe and standard Bently Nevada 8 mm probes?

Answer: The NSv series utilizes a highly narrowed electromagnetic sensing footprint. This allows it to accurate track radial vibration on miniature targets down to 8.9 mm in diameter where standard 8 mm probes would face extreme eddy-current side-loading errors from the machine walls.

Question: Is bench calibration or matched trimming mandatory when swapping out this sensor head?

Answer: No. The product is manufactured to meet precise factory tolerance baselines, enabling complete structural interchangeability. Components can be swapped directly in the field without requiring bench recalibration or parameter scaling adjustments at the main machinery monitor rack.

Quantity
Shipping & Returns

Global Express Shipping

  • Standard Delivery: 4–6 business days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our technical warranty.
Reviews
1 of 3
Only 3 item(s) left in stock
Quantity
View full details

Global Express Shipping

  • Standard Delivery: 4-6 Business Days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries, including rapid delivery to Saudi Arabia and UAE.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our professional technical warranty.

Orders are processed and delivered Monday-Friday (excluding public holidays).


For full eligibility, restocking fees, and international return details, please view our official Refund & Return Policy .

TECHNICAL SPECIFICATIONS

Color pattern
Silver Greyish White Black
Country of origin
United States

Technical knowledge

Diagnosing IC693MDL916 Relay Outputs Before Module Replacement

A field checklist for IC693MDL916 relay commands, terminal blocks, load current, switching rate and contact-side measurements.

Troubleshooting Beckhoff KL1512 Counter Inputs and Mapping

A field checklist for KL1512 signal thresholds, counter direction, process data and the KL1512-to-KS1512 wiring difference.

Troubleshooting Beckhoff EPP2008-0001 Output Faults

A field checklist for EPP2008-0001 current limits, supply voltage, channel LEDs, connector coding and load-related output faults.

Moving TwinCAT 3 Licenses with C9900-L100: Build and Device Checks

Before moving a TwinCAT 3 license with a Beckhoff C9900-L100, verify the TwinCAT build, XML device description, exact order code and cabinet limits.

Replacing a Beckhoff EL4032: Wiring and Output Checks

A field checklist for replacing a Beckhoff EL4032, covering the ±10 V load, terminal map, power contacts, EtherCAT state, and watchdog behavior.

Replacing Yokogawa AAI835: Wiring and Barrier Checks Before Swap

Before replacing a Yokogawa AAI835, verify the 4-in/4-out channel map, power-loss loop behavior, barrier type, output load, cable, and redundancy.