Danfoss

Danfoss 060G3830 MBS 3000-1615-1 Pressure Transmitter

SKU 060G3830

In stock
  • 12-month warranty
  • Free returns within 30 days
  • Manufacturer: Danfoss

  • Product No.: 060G3830

  • Country of origin:United States

  • Product Type: MBS 3000 Pressure Transmitter

  • Payment: T/T, Western Union

  • Weight: 300g

  • Shipping port: Xiamen

  • Warranty: 12 months

The 060G3830 is a high-performance MBS 3000-1615-1 Pressure Transmitter manufactured by Danfoss, designed for heavy-duty industrial applications. This compact pressure transmitter provides reliable measurement in environments with high mechanical loads, such as cavitation, liquid hammer, or pressure peaks. The unit is optimized for a pressure range of 0 to 4 bar using a relative gauge pressure reference and provides a 0-10 V output signal for precise integration into automation and control systems.

Features

  • Robust design resistant to harsh environmental conditions
  • High vibration stability and EMC protection
  • Gauge (relative) pressure measurement from 0 to 4 bar
  • Standardized 0-10 V analog output signal
  • Compact construction with plug connection (EN 175301-803)

Applications

  • Hydraulic systems
  • Compressor and pump monitoring
  • HVAC and water treatment systems
  • Industrial process control
  • Mobile hydraulics and machinery

Technical Specifications

Feature Specification
Manufacturer Danfoss
Product Number 060G3830
Model MBS 3000-1615-1
Pressure Range 0 - 4 bar
Pressure Reference Gauge (relative)
Output Signal 0 - 10 V
Electrical Connection Plug Pg 9 (EN 175301-803)
Net Weight 0.3 Kg
Shipping Weight 1.5 Kg

Installation Guidelines

  • Mounting: Install the transmitter in a position that minimizes exposure to extreme pressure spikes. Ensure the process connection is tightened to the correct torque to prevent leaks.
  • Wiring: Connect the 0-10 V output to the corresponding analog input of your PLC or control device. Ensure proper shielding of the cable to prevent signal noise from nearby power lines.
  • Protection: Although the unit is designed for industrial use, protect the electrical connection (EN 175301-803 plug) from direct water spray or corrosive chemicals.
  • Grounding: Proper grounding of the transmitter housing is recommended to ensure optimal EMC performance and signal stability.

FAQ

What is the pressure measurement range of the 060G3830?

This transmitter measures relative pressure from 0 to 4 bar.

What output signal does this transmitter provide?

It provides a 0-10 V analog output signal.

What type of electrical connection is used?

It uses a Plug Pg 9 connection conforming to EN 175301-803.

View all FAQs →

Quantity
Shipping & Returns

Global Express Shipping

  • Standard Delivery: 4–6 business days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our technical warranty.
Reviews
1 of 1
Only 10 item(s) left in stock
Quantity
View full details

Global Express Shipping

  • Standard Delivery: 4-6 Business Days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries, including rapid delivery to Saudi Arabia and UAE.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our professional technical warranty.

Orders are processed and delivered Monday-Friday (excluding public holidays).


For full eligibility, restocking fees, and international return details, please view our official Refund & Return Policy .

TECHNICAL SPECIFICATIONS

Color pattern
Black
Country of origin
United States

Technical knowledge

Allen-Bradley 1771-IG: TTL Logic and 5 V Wiring Checks

Check 1771-IG TTL HIGH/LOW logic thresholds, field supply ripple and 1771-WC wiring before replacing an input module.

AKS 33 vs AKS 3000: Checks Before Replacing a Pressure Transmitter

A field checklist for distinguishing Danfoss 060G2105, 060G1323 and 060G2109 by pressure range, fitting, loop signal and controller scaling.

Diagnosing DeltaV SE5009 Power Problems Before Replacement

A field checklist for separating 24 VDC input, carrier bus, output derating and alarm-contact faults before replacing an Emerson SE5009.

Commissioning Quantum Inputs with the 140XSM00200 Simulator

A controlled commissioning method for using the 140XSM00200 simulator to verify Modicon Quantum input mapping and interlocks before reconnecting field wiring.

Commissioning PLX32-EIP-MBTCP: Subnets, Registers, and RPI

A commissioning checklist for the ProSoft PLX32-EIP-MBTCP covering subnet separation, register contracts, EtherNet/IP timing, failure tests and replacement records.

Diagnosing IC693MDL916 Relay Outputs Before Module Replacement

A field checklist for IC693MDL916 relay commands, terminal blocks, load current, switching rate and contact-side measurements.