Danfoss

Danfoss 131F9926 FC-102P30KT4E20 Frequency Converter

SKU 131F9926

In stock
  • 12-month warranty
  • Free returns within 30 days
  • Manufacturer: Danfoss

  • Product No.: 131F9926

  • Country of origin:United States

  • Product Type: Frequency Converter

  • Payment: T/T, Western Union

  • Weight: 24000g

  • Shipping port: Xiamen

  • Warranty: 12 months

The 131F9926 is a robust FC-102P30KT4E20 Frequency Converter belonging to the Danfoss VLT HVAC Drive FC 102 series. This drive is specifically optimized for heating, ventilation, and air conditioning (HVAC) applications, providing precise control for 30 kW (40 HP) three-phase AC motors. The unit operates within a 380-480 VAC input range and is housed in an IP20-rated enclosure for standard cabinet mounting.

Features

  • Dedicated HVAC control algorithms for pump and fan optimization
  • Integrated power management for three-phase motor operation
  • Compact IP20 chassis design for efficient installation
  • High reliability in continuous industrial and commercial HVAC service
  • Standard voltage compatibility for global industrial power grids

Applications

  • Commercial and industrial ventilation systems
  • Chiller and cooling tower fan control
  • Building HVAC automation and pumping stations
  • Air handling units

Technical Specifications

Feature Specification
Manufacturer Danfoss
Product Number 131F9926
Model FC-102P30KT4E20
Product Group VLT HVAC Drive FC 102
Power Rating 30 KW / 40 HP
Voltage Input 380-480 VAC
Phases Three Phases
Enclosure Rating IP20
Net Weight 20.44 Kg
Shipping Weight 24 Kg

Installation Guidelines

  • Mounting: Install the frequency converter in a vertical position on a solid, non-combustible surface.
  • Ventilation: Ensure sufficient space is provided above and below the drive to facilitate airflow through the heat sink and prevent thermal degradation.
  • Grounding: Connect the chassis to a verified system protective earth to ensure operational safety and compliance with EMI standards.
  • Wiring: Use properly sized cables for the power input and motor output. Segregate power and control wiring to minimize electrical interference.
  • Environment: The device should be operated in an environment free from conductive dust, corrosive gases, and excessive moisture to maintain the integrity of the internal electronics.

FAQ

What is the intended application for the 131F9926 drive?

This unit is part of the VLT HVAC Drive FC 102 series, specifically designed for HVAC systems like fans, pumps, and air handling units.

What is the power rating of this model?

The 131F9926 is rated for 30 kW (40 HP) applications.

What is the enclosure rating for this unit?

The device features an IP20 enclosure rating.

View all FAQs →

Quantity
Shipping & Returns

Global Express Shipping

  • Standard Delivery: 4–6 business days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our technical warranty.
Reviews
1 of 1
Only 10 item(s) left in stock
Quantity
View full details

Global Express Shipping

  • Standard Delivery: 4-6 Business Days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries, including rapid delivery to Saudi Arabia and UAE.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our professional technical warranty.

Orders are processed and delivered Monday-Friday (excluding public holidays).


For full eligibility, restocking fees, and international return details, please view our official Refund & Return Policy .

TECHNICAL SPECIFICATIONS

Color pattern
Greyish White
Country of origin
United States

Technical knowledge

Seal-In Logic or OTL/OTU? Choosing PLC Memory Safely

Seal-in circuits and OTL/OTU instructions can hold the same command, but they fail differently. This guide compares scan behavior, restart risk, troubleshooting, permissives, and safer PLC design...

Commissioning a Micro800 PLC in FactoryTalk Design Workbench

A practical Micro800 commissioning workflow covering hardware checks, USB and Ethernet discovery, safe ladder testing, download risks, fault isolation, and project recovery in FactoryTalk Design...

Derivative Action in PID Control Without Noise Problems

Learn what derivative action contributes to a PID loop, why it can amplify measurement noise and setpoint changes, and how filtering, sampling, and staged tests make D tuning safer.

Designing Industrial Networks That Stay Troubleshootable

A practical guide to segmenting, documenting, and testing industrial Ethernet networks so plant teams can isolate faults quickly, control change, and expand without creating fragile dependencies.

Commissioning IO-Link From Master Ports to IODD Data

Commission IO-Link systematically from master addressing and port modes through IODD selection, PLC byte mapping, parameter backups, device validation, and failure-injection tests.

PowerFlex Dynamic Braking Resistor Design and Testing

A practical PowerFlex braking guide covering regenerative energy, resistor resistance and duty cycle, thermal protection, model-specific parameters, and measured commissioning tests.