Danfoss

Danfoss 132F0014 FC-051P2K2T2E20H3BXCXXXSXXX VLT Micro Drive

SKU 132F0014

In stock
  • 12-month warranty
  • Free returns within 30 days
  • Manufacturer: Danfoss

  • Product No.: 132F0014

  • Country of origin:United States

  • Product Type: FC-051P2K2T2E20H3BXCXXXSXXX VLT® Micro Drive

  • Payment: T/T, Western Union

  • Weight: 5000g

  • Dimensions: 19.4 cm x 9 cm x 23.9 cm

  • Shipping port: Xiamen

  • Warranty: 12 months

Product Overview

The Danfoss 132F0014 (FC-051P2K2T2E20H3BXCXXXSXXX) VLT Micro Drive is a precision-engineered frequency converter optimized for low-voltage industrial applications. It serves as a vital component in power-sensitive environments such as conveyor systems, machine tools, and process ventilation, where maintaining continuous uptime is critical. By employing advanced VVC+ flux control, this 2.2 kW drive ensures high motor torque stability and exceptional energy efficiency, significantly reducing mechanical wear on driven equipment. Its compact chassis design allows for high-density installation in limited-space control cabinets, providing a reliable, long-term solution for demanding 200-240 VAC power infrastructure.

Technical Configuration

The 132F0014 model string identifies a 2.2 kW (3.0 HP) drive optimized for 200-240 VAC three-phase supply voltage. The "P2K2" designation signifies its power capacity, while the "T2" identifies the voltage class. This unit is housed in an IP20 chassis suitable for protected environments. It includes an integrated "H3" RFI filter for Class A1/B (C1) electromagnetic compliance, ensuring minimal interference with surrounding electronic instrumentation. The hardware features a factory-fitted internal brake chopper for dynamic braking requirements, and the internal PCB is treated with a conformal coating ("C") to enhance durability against humidity and atmospheric contaminants typical in industrial processing zones.

Technical Specifications

Feature Specification
Model 132F0014
Brand Danfoss
Series VLT Micro Drive FC-051
Power Rating 2.2 kW / 3.0 HP
Output Current 9.6 A
Mains Voltage 200 - 240 VAC (3-phase)
Supply Frequency 50/60 Hz
Enclosure Class IP20
PCB Coating Coated
Operating Temp -10 to 50 deg C
Dimensions (L x W x H) 19.4 cm x 9 cm x 23.9 cm
Weight 5 kg

FAQs

Is this drive suitable for single-phase motor control?

No, this specific model (T2 designation) is designed strictly for three-phase motor applications. Connecting it to a single-phase motor will lead to operational faults and potential hardware failure.

Does the 132F0014 include a built-in display for parameter monitoring?

This specific unit does not ship with a Local Control Panel (LCP). Monitoring and parameter modification must be conducted via a detachable LCP or through serial communication using external configuration software.

Can the unit handle high-humidity environments?

Yes, the "C" suffix indicates the internal printed circuit board is conformal coated, providing a robust barrier against corrosion in humid or mildly aggressive industrial atmospheres.

What is the maximum frequency output of this drive?

The unit can deliver up to 200 Hz in VVC+ mode for standard applications and up to 400 Hz when utilizing U/f control mode for high-speed motor operations.

Installation and Operational Guidelines

  • Mounting and Thermal Management: Given the power density of this 2.2 kW unit, ensure the drive is mounted vertically on a flat, heat-conductive surface. Maintain at least 100 mm of clearance above and below the drive to facilitate natural airflow; if ambient temperatures exceed 40 deg C, forced ventilation within the cabinet is mandatory to prevent thermal derating.
  • Cable Selection and Shielding: To comply with electromagnetic compatibility standards, use double-screened motor cables. The cable shield must be clamped 360 degrees to the drive's earth terminal using the provided metal brackets to ensure low-impedance high-frequency grounding, which effectively prevents RFI leakage into the control network.
  • Safety Protocol: Always isolate the main power source before performing any terminal connections. Due to the storage of energy in the DC link capacitors, wait a minimum of 4 minutes after power-off before opening the cover or touching the internal terminals to ensure the voltage has bled off to a safe level.
Quantity
Shipping & Returns

Global Express Shipping

  • Standard Delivery: 4–6 business days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our technical warranty.
Reviews
1 of 1
Only 10 item(s) left in stock
Quantity
View full details

Global Express Shipping

  • Standard Delivery: 4-6 Business Days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries, including rapid delivery to Saudi Arabia and UAE.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our professional technical warranty.

Orders are processed and delivered Monday-Friday (excluding public holidays).


For full eligibility, restocking fees, and international return details, please view our official Refund & Return Policy .

TECHNICAL SPECIFICATIONS

Color pattern
Black
Country of origin
United States

Technical knowledge

Moving TwinCAT 3 Licenses with C9900-L100: Build and Device Checks

Before moving a TwinCAT 3 license with a Beckhoff C9900-L100, verify the TwinCAT build, XML device description, exact order code and cabinet limits.

Replacing a Beckhoff EL4032: Wiring and Output Checks

A field checklist for replacing a Beckhoff EL4032, covering the ±10 V load, terminal map, power contacts, EtherCAT state, and watchdog behavior.

Replacing Yokogawa AAI835: Wiring and Barrier Checks Before Swap

Before replacing a Yokogawa AAI835, verify the 4-in/4-out channel map, power-loss loop behavior, barrier type, output load, cable, and redundancy.

ABB PM891K01 Replacement: Check Redundancy Before Ordering

ABB PM891K01 article 3BSE053241R1 is the non-redundant AC 800M processor kit. Use this field checklist before replacement.

ABB TP853 Replacement Checks for CI853/CI855/CI857/CI861

Replacement checks for ABB TP853 3BSE018126R1: identify the installed CI853, CI855, CI857, or CI861 interface, record wiring, and verify communication after installation.

5069-L330ERMS2 Startup Checks: RTBs, I/O, and Motion Limits

Engineering checks for the Allen-Bradley 5069-L330ERMS2: controller capacity, separate RTB kits, local I/O limits, network-node limits, and motion-axis count.