The Emerson EPRO MMS 6250 is a shaft position monitor designed for measuring and protecting against inadmissible high axial displacements of turbine shafts. Operating as a microcontroller-based 3-channel measuring system, the MMS 6250 standardizes and processes differential input signals from eddy current sensors (such as PR 642x series) to evaluate axial shaft positions. The module incorporates dual redundant +24 VDC power supply inputs, an RS 232 front interface for computer configuration, an RS 485 bus interface for host communication, and optional PROFIBUS-DP connectivity via a front SUB-D socket. It features comprehensive internal module supervision, signal conditioning circuitry, six configurable binary 24 V voltage outputs, and two current outputs per channel (one electrically isolated) for integration into plant protection networks.

Features

  • Microcontroller-based 3-channel axial position measuring and protection system
  • Support for redundant +24 VDC power supply inputs decoupled via diodes
  • Self-test functions for internal electronic circuits, processor watchdog, and sensor signal lines
  • Two current outputs per channel (one electrically isolated from system ground)
  • Six configurable 24 V binary function and alarm outputs
  • RS 232 front connector for configuration via PC and RS 485 bus interface for host data exchange
  • Optional PROFIBUS-DP interface via front-panel 9-pin SUB-D socket
  • Front-panel SMB socket for decoupled sensor signal output
  • Hot-swap capability during system operation
  • Password protection per monitor for high operational safety

Applications

  • Turbine shaft axial position displacement measurement and protection
  • Power plant safety shut-off valve control integration
  • Replacement and upgrade of mechanical position control and protection systems

Ordering Information

Model Description Order Number
MMS 6250 Shaft displacement monitor 9100-00057
MMS 6250/D Shaft displacement monitor with display 9100-00056
MMS 6250D/DP Shaft displacement monitor with display and Profibus DP 9100-00084
MMS 6351/00 Backplane for System DAPS 9100-00047
MMS 6351/10 Backplane for System DAPS AS 9100-00049
MMS 6352 19 inch mounting frame 9100-00053
MMS 6360 Cable 25 pole SUB D 3 m 9510-00006
MMS 6362 Cable 25 pole SUB D 0.5 m 9510-00015
MMS 6363 Profibus cable 4 m 9510-00024
MMS 6361 Screw terminal 25 pol. SUB D 9100-00052
MMS 6950 Configuration kit 9510-00005
MMS 6354 Set of blind plates 9501-00005
BLE 008 Blind plate 8 TE 9501-00003

Technical Specifications

Parameter Value
Manufacturer Emerson / epro
Country of Origin Germany
Input Signal Type Differential input, non-reactive, open-circuit and short-circuit proof
Input Voltage Range 0 to 27.3 VDC (Limit range: 0 to 30 VDC)
Input Resistance > 100 kOhm
Measuring Error < 1% of the measuring range
Sensor Signal Output (SENS) SMB socket, voltage range 0 to 4.1 V (Sensor signal x 0.15), internal resistance 10 kOhm, load > 1 MOhm
Current Output 1 (Iout1) 0/4 to 20 mA or 20 to 4/0 mA, electrically isolated from system ground, accuracy +-1% full scale (16 bit)
Current Output 2 (Iout2) 0/4 to 20 mA or 20 to 4/0 mA, referenced to system ground, accuracy +-1% full scale (16 bit)
Sensor Supply Voltage 26.75 VDC, max. 38 mA, residual ripple < 20 mVss (at 20 mA), open and short-circuit proof
Binary Outputs 6 outputs, +18 to 32 V (High state), 0 to +3.5 V (Low state), Iout max 25 mA
Binary Inputs Voltage inputs +24 V, High: +13 to +32 V, Low: 0 to +3 V, input resistance 6.8 kOhm
Module Power Supply Redundant +18 to 24 to 32 VDC (according to IEC 60654-2)
Current Consumption Max. approx. 250 mA per card
Front Panel Width 6 TE (approx. 30 mm) without display; 14 TE (approx. 71 mm) with display
PCB Format Euro-Format (100 x 160 mm) according to DIN 41 494
Rear Connector DIN 41 612, design F 48 M
Operating Temperature 0 to +55 degC (max. +65 degC), reference temperature +23 degC
Storage Temperature -40 to +70 degC
Relative Humidity 5 to 95%, non-condensing
Vibration Resistance 0.15 mm amplitude (10 to 55 Hz), 19.6 m/s2 acceleration (55 to 150 Hz) according to IEC-68-2 part 6
Shock Resistance Peak acceleration 98 m/s2, nominal duration 16 ms according to IEC-68-2 part 29
Protection Class IP 00 (Module), IP 21 (Front plate) according to DIN 40050

Installation Guidelines

  • Ensure the module is installed into a compatible 19 inch mounting frame (MMS 6352) with an appropriate backplane (MMS 6351/00 or MMS 6351/10).
  • Connect the dual redundant +24 VDC power supply inputs to ensure uninterrupted module operation.
  • Secure all field wiring to the designated screw terminal blocks (MMS 6361) using shielded cabling to prevent signal interference.
  • Adjust probe gap voltages and verify transducer supply parameters before enabling alarm outputs.
  • Utilize the front RS 232 interface via mini DIN diode socket to perform initial configuration and parameter download using a compatible PC.

Compliance and Certifications

  • CE
Loading product navigation…

Product Documentation

Technical Datasheet (PDF) Complete specifications and technical drawings.

Technical Datasheet

Emerson EPRO MMS 6250 Machine Monitoring Systems Shaft Position Monitor

What power supply voltage is required for operating the module?

The module operates on a nominal +24 VDC redundant supply with an acceptable input voltage range of +18 to +32 VDC.

Which connector types are available on the front panel of the monitor?

The front panel features an SMB socket for buffered sensor signal output and a mini DIN socket for RS 232 serial configuration.

What standard form factor does the circuit board conform to?

The module circuit board is designed in Euro-Format measuring 100 x 160 mm according to DIN 41 494 specifications.

Global Express Shipping

  • Standard Delivery: 4-6 Business Days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries, including rapid delivery to Saudi Arabia and UAE.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our professional technical warranty.

Orders are processed and delivered Monday-Friday (excluding public holidays).


For full eligibility, restocking fees, and international return details, please view our official Refund & Return Policy .

TECHNICAL SPECIFICATIONS

Color pattern
Black
Country of origin
United States
Power source
DC Power

Recently Viewed Products

Technical knowledge

Micro Drive Specialist EMS Bets on Custom Engineering to Broaden Market Appeal

UK micro-drive specialist EMS is pairing Faulhaber high-torque gearheads and compact motion controllers with in-house custom engineering—aiming beyond catalog sales into tailored mechatronics.

Bringing Object-Oriented Thinking to PLC Programming

Copy-paste ladder does not scale. Object-oriented PLC techniques—user-defined structures and instructions—cut duplication, propagate fixes once, and keep large multi-device programs readable.

Why Process Safety Management Programs Fail Even When OSHA Boxes Are Checked

OSHA boxes checked is not the same as a living PSM system. Refinery history shows programs fail when procedures, training, contractors, and investigations drift from how the plant actually runs.

What Is SCADA? Supervisory Control Without Replacing the PLC

SCADA sits above PLCs and RTUs: it acquires field data, alarms operators, and issues supervisory commands across plants and remote assets—without replacing local deterministic control.

What Is a VFD? Variable Frequency Drives That Actually Move the Needle

A VFD turns fixed-frequency mains into controlled voltage and frequency so AC motors match real load—cutting pump and fan energy while tightening torque, soft-start, and braking behavior.

What Is a PLC? The Controllers That Still Run the Plant Floor

PLCs still run the plant floor: scan cycles, I/O, and IEC 61131-3 languages decide whether machines stay deterministic. Here is how controllers work, where they win, and where they strain.